Skip to content
Loading map…

Paris Nails

312-25 Peel Centre Dr Brampton ON L6T 3R5 · Manicure / Pedicure

3 inspections

  1. Required

    3 infractions

    • Did operator maintain setting and work surfaces in a safe and sanitary condition?
    • Did operator discard single use equipment immediately after each use?
      • Discard single use equipment immediately after use.
      • Ensure that all equipment designed for single use or made of a material that does not withstand cleaning and disinfection or sterilization is discarded immediately after use (e.g., nail files, buffer blocks, gloves, sponges, applicator sticks, ear piercing adapters).
    • Did operator properly disinfect equipment and surfaces?
      • Disinfect reusable equipment after use on a client to prevent disease transmission.
      • Disinfect reusable equipment with appropriate disinfectant required for the equipment.
      • Fully immerse reusable equipment in the disinfectant.
      • Low-level disinfect equipment and surfaces that do not directly contact the client, or contact only hair or intact skin (e.g., combs, reusable handles/holders for blades, magnifying glasses, equipment covered with single use disposable plastic liner, client chairs, client beds).
      • Clean and low-level disinfect low-risk environmental surfaces (e.g., manicure/waxing tables, chairs, or beds that are covered with a single-use towel/ cover) at the end of the day or when visibly soiled.
      • Intermediate-level disinfectant: Mix 20 ml (4 tsp) of 5.25% bleach with 500 ml (2 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 5 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • Pedicure basin with single use disposable liner: Clean the basin with detergent, water and scrub brush after every use. Clean and low level disinfect at the end of the day. If the liner tears or breaks while in use, clean and intermediate level disinfect the basin immediately after use. If a magnetic jet cover is used in the spa water, it must be cleaned and intermediate level disinfected after every use. (Show More)
  2. Follow-up

    0 infractions

  3. Required

    6 infractions

    • Did operator maintain setting and work surfaces in a safe and sanitary condition?
      • Ensure work surfaces are of such form and material that they can be readily cleaned and disinfected.
      • Provide adequate storage space for necessary equipment and supplies.
      • Remove equipment and supplies no longer used/required for the operation of the setting.
    • Did operator discard single use equipment immediately after each use?
      • Discard single use equipment immediately after use.
      • Ensure that all equipment designed for single use or made of a material that does not withstand cleaning and disinfection or sterilization is discarded immediately after use (e.g., nail files, buffer blocks, gloves, sponges, applicator sticks, ear piercing adapters).
    • Did operator maintain reusable equipment in good repair and sanitary condition?
      • Ensure all equipment is maintained in good repair and in a sanitary condition.
      • Store cleaned and disinfected equipment in a sanitary condition.
      • Discard cracked, chipped, rusted or damaged equipment.
    • Did operator properly clean reusable equipment?
      • Clean reusable equipment after use on a client to prevent disease transmission.
    • Did operator properly disinfect equipment and surfaces?
      • Disinfect reusable equipment after use on a client to prevent disease transmission.
      • Disinfect reusable equipment with appropriate disinfectant required for the equipment.
      • Fully immerse reusable equipment in the disinfectant.
      • Provide a low-level disinfectant and ensure it is easily accessible.
      • Low-level disinfectant: Mix 2 ml (½ tsp) of 5.25% bleach with 1 L (4 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 10 minutes. Prepare a new bleach and water solution daily.
      • Low-level disinfect equipment and surfaces that do not directly contact the client, or contact only hair or intact skin (e.g., combs, reusable handles/holders for blades, magnifying glasses, equipment covered with single use disposable plastic liner, client chairs, client beds).
      • Low-level disinfect equipment that has been protected with a single use disposable cover.
      • Clean and low-level disinfect low-risk environmental surfaces (e.g., manicure/waxing tables, chairs, or beds that are covered with a single-use towel/ cover) at the end of the day or when visibly soiled.
      • Intermediate-level disinfectant: Mix 20 ml (4 tsp) of 5.25% bleach with 500 ml (2 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 5 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • Intermediate-level disinfect equipment such as nail clippers, cuticle nippers, nail drill bits, ear piercing device, single-use ink caps, tweezers and scissors used in hair removal services.
      • Pedicure basin with single use disposable liner: Clean the basin with detergent, water and scrub brush after every use. Clean and low level disinfect at the end of the day. If the liner tears or breaks while in use, clean and intermediate level disinfect the basin immediately after use. If a magnetic jet cover is used in the spa water, it must be cleaned and intermediate level disinfected after every use. (Show More)
      • Provide a high-level disinfectant and ensure it is easily accessible.
      • High-level disinfectant: Mix 125 ml (½ cup) of 5.25% bleach with 1 L (4 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 10 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • High-level disinfect equipment such as grater-style foot files, comedone extractor with loops on both ends, and diamond microdermabrasion tips.
      • High-level disinfect equipment that holds, manipulates or contacts sterile items (e.g., needle probe holder, microblading handle, microneedle roller handle, micropigmentation reusable needle sleeve and front casing).
    • Did operator properly use and maintain cleaning and disinfecting products?
      • Provide a disinfecting container with a lid or cover that is capable of fully immersing equipment in the disinfectant.
      • Ensure prepared disinfectant solutions are not topped up with fresh solution (i.e., do not add new solution to the current solution). Containers must be emptied, cleaned, disinfected, rinsed, and dried before refilling.
      • Follow manufacturer's instructions for use of cleaning and disinfecting product(s), where available.
      • Follow manufacturer's instructions for contact times of disinfectant product(s), where available.