Park Terrace - YRCC 845/ 860
81 Townsgate Drive, Thornhill, Vaughan, Thornhill, Vaughan, ON L4J 8E6 · Class B
6 inspections
- Compliance Inspection
2 infractions
- Cyanuric acid concentration at 60 mg/L or less, where appropriate
- Fail to maintain cyanuric acid concentration in an outdoor pool at 60 mg/L or less
- Other tests and records completed and signed
- Fail to determine and record concentration of cyanuric acid at least once a week, where applicable
- Cyanuric acid concentration at 60 mg/L or less, where appropriate
- Re-inspection
0 infractions
- Compliance Inspection
2 infractions
- Free available chlorine (FAC) residual is within required range
- Fail to maintain stabilized free available chlorine (FAC) residual between 1.0 - 10 ppm (Outdoor Pool with cyanurate stabilization)
- All components of the facility maintained in proper working order
- Fail to ensure all components of the facility unit are maintained in proper working order
- Free available chlorine (FAC) residual is within required range
- Compliance Inspection
2 infractions
- Facility conducts required tests at appropriate intervals, as required
- Fail to manually test TA, pH, FAC, TC or TBr, water clarity and water temperature (Spa, Hot Water Pool) every 2 hours during daily use period where automatic sensing device is not used
- Other tests and records completed and signed
- Fail to determine and record concentration of cyanuric acid at least once a week, where applicable
- Facility conducts required tests at appropriate intervals, as required
- Compliance Inspection
1 infraction
- Depth markings present in appropriate locations
- Fail to display markings in figures not less than 100 millimeters high setting out water depth
- Depth markings present in appropriate locations
- Compliance Inspection
2 infractions
- Cyanuric acid concentration at 60 mg/L or less, where appropriate
- Fail to maintain cyanuric acid concentration in an outdoor pool at 60 mg/L or less
- Other tests and records completed and signed
- Fail to ensure water, gravity, and suction outlet covers are inspected at least once in each 30 day operating period
- Fail to determine and record concentration of cyanuric acid at least once a week, where applicable
- Cyanuric acid concentration at 60 mg/L or less, where appropriate