Skip to content
Loading map…

Pinedale Inn Motel

200 Pinedale Lane, Gravenhurst ON P1P 1B4 · Swimming Pool Class B - Outdoor

Inspection summary

Pinedale Inn Motel has been inspected 9 times by Simcoe Muskoka District Health Unit since June 11, 2025. The most recent inspection, on August 14, 2026, found no infractions.

2 of 9 inspections on record found no infractions at all. In the past 12 months there were 6 inspections with 15 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

Recent inspections have recorded fewer infractions than earlier ones, so the record is improving.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 6 times across 4 separate inspections, most recently on August 13, 2026. For example: Stabilized free available chlorine (FAC) within range of 1 ppm to 10 ppm.

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded once on September 2, 2025. For example: Chemical feeder is used to administer chlorine, chlorine compound or bromine.

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded 4 times across 4 separate inspections, most recently on August 7, 2026. For example: Daily records are kept and signed each operating day.

  • Building, plumbing and upkeepLower risk

    Decks, ladders, fencing, drains, washrooms and signage must be in good repair. Damaged drain covers or broken fencing can be real safety hazards, while most other upkeep issues are lower risk.

    Recorded 3 times across 3 separate inspections, most recently on August 13, 2026. For example: Premises is operated and maintained free from conditions that may be an immediate health hazard.

  • Equipment and utensilsLower risk

    Pumps, filters, chemical feeders and safety equipment such as lifebuoys, reaching poles and first-aid kits must be present and working. Missing safety equipment can matter a great deal in an emergency.

    Recorded once on June 17, 2026. For example: Public pool and its equipment maintained in a safe and sanitary condition and in proper working order.

About this data

These results come from Simcoe Muskoka District Health Unit, which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

9 inspections

  1. Follow-up

    0 infractions

  2. Follow-up

    3 infractions

    • Stabilized free available chlorine (FAC) within range of 1 ppm to 10 ppm.
      • CLOSE
      • Fail to ensure residual of stabilized FAC of public pool water maintained between 1ppm to 10 ppm
    • Cyanuric stabilization is only used outdoors and is not greater than 60 ppm.
      • CLOSE
      • Fail to ensure appropriate cyanuric acid concentration
    • Premises is operated and maintained free from conditions that may be an immediate health hazard.
      • CLOSE IMMEDIATELY
      • Fail to operate and maintain premises free from conditions that may be an immediate health hazard
  3. Follow-up

    3 infractions

    • Stabilized free available chlorine (FAC) within range of 1 ppm to 10 ppm.
      • CLOSE
      • Fail to ensure residual of stabilized FAC of public pool water maintained between 1ppm to 10 ppm
    • Cyanuric stabilization is only used outdoors and is not greater than 60 ppm.
      • CLOSE
      • Fail to ensure appropriate cyanuric acid concentration
      • Fail to determine concentration of cyanuric acid not less than once every week
    • Premises is operated and maintained free from conditions that may be an immediate health hazard.
      • CLOSE IMMEDIATELY
      • Fail to operate and maintain premises free from conditions that may be an immediate health hazard
  4. Follow-up

    3 infractions

    • Cyanuric stabilization is only used outdoors and is not greater than 60 ppm.
      • Fail to ensure appropriate cyanuric acid concentration
    • Daily records are kept and signed each operating day.
      • Fail to keep daily record of estimated number of bathers
    • Operator conducts and documents inspections at required frequency.
      • Fail to ensure water outlet and suction covers inspected at least once every 30 operating days
  5. Routine

    3 infractions

    • Cyanuric stabilization is only used outdoors and is not greater than 60 ppm.
      • Fail to ensure appropriate cyanuric acid concentration
      • Fail to determine concentration of cyanuric acid not less than once every week
    • Daily records are kept and signed each operating day.
      • Fail to keep daily record of estimated number of bathers
      • Fail to keep daily record of reading of make-up water meter
    • Operator conducts and documents inspections at required frequency.
      • Fail to ensure water outlet and suction covers inspected at least once every 30 operating days
      • Fail to ensure test buttons associated with ground current leakage detecting or de-energizing devices tested monthly or according to manufacturer’s instructions
      • Fail to create a written record of each inspection required and have it available for viewing by a public health inspector
  6. Routine

    3 infractions

    • Stabilized free available chlorine (FAC) within range of 1 ppm to 10 ppm.
      • Fail to ensure residual of stabilized FAC of public pool water maintained between 1ppm to 10 ppm
    • Public pool and its equipment maintained in a safe and sanitary condition and in proper working order.
      • Fail to ensure all components of pool maintained in proper working order
    • Pool is equipped with anti-entrapment drain cover(s)
      • Failed to provide anti-entrapment drain cover.
  7. Routine

    7 infractions

    • Black disc on white background is permanently affixed to the bottom of the pool at its deepest point.
      • CLOSE
      • Fail to provide black disc
      • Fail to ensure black disc is permanently affixed to bottom of the pool at its deepest point
    • Cyanuric stabilization is only used outdoors and is not greater than 60 ppm.
      • Fail to ensure appropriate cyanuric acid concentration
    • Chemical feeder is used to administer chlorine, chlorine compound or bromine.
      • Fail to ensure water is treated with chlorine, a chlorine compound or bromine by means of chemical feeder
    • Daily records are kept and signed each operating day.
      • Fail to keep daily record of manual tests as required
    • Make-up water added daily.
      • Fail to add required amount of fresh water to the pool daily
    • Pool is equipped with anti-entrapment device or pool design (i.e.: unblockable drain, multiple main drains 3 feet apart, gravity drain system)
      • Failed to maintain public pool and its equipment in a safe condition.
    • Premises is operated and maintained free from conditions that may be an immediate health hazard.
      • CLOSE IMMEDIATELY
      • Fail to operate and maintain premises free from conditions that may be an immediate health hazard
  8. Follow-up

    0 infractions

  9. Routine

    3 infractions

    • Daily records are kept and signed each operating day.
      • Fail to keep daily record of estimated number of bathers
      • Fail to keep daily record of reading of make-up water meter
    • Depth markings present in the appropriate locations.
      • Fail to display markings setting out breaks between gentle and steep bottom slopes and shallow points
    • Pool notices contain required information and displayed in correct places.
      • Fail to ensure notice displayed in two places setting out location of emergency telephone
      • Fail to display notice setting out maximum number of bathers permitted in the pool and on the deck

Nearby inspected facilities