Skip to content
Loading map…

Pomeroy Kananaskis Mountain Lodge - Swimming Pool

1 Centennial Drive Kananaskis Village AB T0L 2H0 · Aquatic Facility

15 inspections

  1. Monitoring Inspection

    5 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity was measured as 51ppm. Should be maintained between 60-180ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Several of the circular weirs were not sitting properly in the skimmer; water level was also too high for the weirs. Please ensure all weirs are properly skimming the surface water.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • There was a leak from the chlorine injection point; please repair.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was no flow meter for the waterfall feature pump. Please install a flow meter.Some of the floats in the flow meters appeared stuck. Please ensure all flow meters are reading accurately.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There is no flow meter for determining the flow through at least one of the individual filters. Please install an additional flow meter so the flow through each filter can be determined.
  2. Risk Management Inspection

    3 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The pH was measured as 7.42. The controller was reading 7.86. pH probe needs calibration.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Some of the weirs are still missing from the skimmers. To be replaced.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There is no flow meter for determining the flow through at least one of the individual filters. Please install an additional flow meter so the flow through each filter can be determined.
  3. Risk Management Inspection

    3 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The pH was measured as 7.42. The controller was reading 7.86. pH probe needs calibration.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Some of the weirs are still missing from the skimmers. To be replaced.There is paint chipped off the stairs for the bear slide and now some damage on the bottom stair that has been patched but needs to be smoothed out. Please repair/repaint.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There is no flow meter for determining the flow through at least one of the individual filters. Please install an additional flow meter so the flow through each filter can be determined.
  4. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample taken on March 7/25 was not tested as it was received at the lab after it had already closed for the weekend.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The pH was measured as 7.42. The controller was reading 7.86. pH probe needs calibration.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Some of the weirs are still missing from the skimmers. To be replaced.There is paint chipped off the stairs for the bear slide and now some damage on the bottom stair that has been patched but needs to be smoothed out. Please repair/repaint.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There is no flow meter for determining the flow through at least one of the individual filters. Please install an additional flow meter so the flow through each filter can be determined.
  5. Demand Inspection

    3 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The pH was measured as 7.42. The controller was reading 7.86. pH probe needs calibration.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Some of the weirs are still missing from the skimmers. To be replaced.There is paint chipped off the stairs for the bear slide and now some damage on the bottom stair that has been patched but needs to be smoothed out. Please repair/repaint.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There is no flow meter for determining the flow through at least one of the individual filters. Please install an additional flow meter so the flow through each filter can be determined.
  6. Risk Management Inspection

    2 infractions

    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Some of the weirs are still missing from the skimmers. To be replaced.There is paint chipped off the stairs for the bear slide and now some damage on the bottom stair. Please repair/repaint.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There is no flow meter for determining the flow through at least one of the individual filters. Please install an additional flow meter so the flow through each filter can be determined.
  7. Monitoring Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity was measured as 48 ppm.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Most of the weirs are missing from the skimmers. To be replaced.There is paint chipped off the stairs for the bear slide and now some damage on the bottom stair. Please repair/repaint.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow rate for the circulation system could not be determined as the float was stuck in the flow meter. Repair the flow meter.There is no flow meter for determining the flow through at least one of the individual filters. Please install an additional flow meter so the flow through each filter can be determined.
  8. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • May 10/24 water sample was not processed as there was no time of collection on the requisition form and id# sticker on the bottle. Resample to be taken.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity was measured as 48 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The main drain line was fully open and the skimmer line was only partially open. Skimmer line to be fully open to maximize flow through the skimmers.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Most of the weirs are missing from the skimmers. To be replaced.The flow meter for the shallow features appears to be stuck. To be fixed.The flow meter for the compact slide is either stuck or the range for the flow meter is too low for the pump (float was at very top of the flow meter). To be fixed.There is paint chipped off the stairs for the bear slide. Please repair/repaint.
  9. Risk Management Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity was measured as 48 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The main drain line was fully open and the skimmer line was only partially open. Skimmer line to be fully open to maximize flow through the skimmers.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Most of the weirs are missing from the skimmers. To be replaced.The flow meter for the shallow features appears to be stuck. To be fixed.The flow meter for the compact slide is either stuck or the range for the flow meter is too low for the pump (float was at very top of the flow meter). To be fixed.There is paint chipped off the stairs for the bear slide. Please repair/repaint.
  10. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted May 3, 2024 was submitted under the wrong access number and there was insufficient information on the requisition form to verify the sample. Resample to be submitted.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity was measured as 48 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The main drain line was fully open and the skimmer line was only partially open. Skimmer line to be fully open to maximize flow through the skimmers.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Most of the weirs are missing from the skimmers. To be replaced.The flow meter for the shallow features appears to be stuck. To be fixed.The flow meter for the compact slide is either stuck or the range for the flow meter is too low for the pump (float was at very top of the flow meter). To be fixed.There is paint chipped off the stairs for the bear slide. Please repair/repaint.
  11. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample taken and dropped off at lab on March 29/24 when it was closed (for stat holiday) so sample was not tested. Resample to be submitted.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity was measured as 48 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The main drain line was fully open and the skimmer line was only partially open. Skimmer line to be fully open to maximize flow through the skimmers.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Most of the weirs are missing from the skimmers. To be replaced.The flow meter for the shallow features appears to be stuck. To be fixed.The flow meter for the compact slide is either stuck or the range for the flow meter is too low for the pump (float was at very top of the flow meter). To be fixed.There is paint chipped off the stairs for the bear slide. Please repair/repaint.
  12. Monitoring Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity was measured as 48 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The main drain line was fully open and the skimmer line was only partially open. Skimmer line to be fully open to maximize flow through the skimmers.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Most of the weirs are missing from the skimmers. To be replaced.The flow meter for the shallow features appears to be stuck. To be fixed.The flow meter for the compact slide is either stuck or the range for the flow meter is too low for the pump (float was at very top of the flow meter). To be fixed.There is paint chipped off the stairs for the bear slide. Please repair/repaint.
  13. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample taken on Feb 2/24 had a plate count of 570cfu/ml. Treat water to remove contamination.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity was measured as 33ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The main drain line was fully open and the skimmer line was only partially open. Skimmer line to be fully open to maximize flow through the skimmers.
  14. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample taken on Jan. 10/24 had a plate count of 570cfu/ml. Treat water to remove contamination.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity was measured as 33ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The main drain line was fully open and the skimmer line was only partially open. Skimmer line to be fully open to maximize flow through the skimmers.
  15. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample taken Aug. 29/23 was not tested as there was no time of collection on the form. Resample needed.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity was measured as 33ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The main drain line was fully open and the skimmer line was only partially open. Skimmer line to be fully open to maximize flow through the skimmers.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plan provided but information is missing as to the maximum flow rate would get from pumps (all 7). The pictures provided of the main drain sumps don't clearly show the required 18" of space from the top of the main drain pipe to top of the main drain cover. Please update anti-entrapment plan and provide.