Skip to content
Loading map…

Pomeroy Kananaskis Mountain Lodge - Whirlpool

1 Centennial Drive Kananaskis Village AB T0L 2H0 · Aquatic Facility

Inspection summary

Pomeroy Kananaskis Mountain Lodge - Whirlpool has been inspected 23 times by Alberta Health Services (Environmental Public Health) since November 2, 2023. The most recent inspection, on May 26, 2026, recorded 3 infractions.

None of the 23 inspections on record were free of infractions. In the past 12 months there were 7 inspections with 25 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality, Food temperature control and Chemicals and toxic substances.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 62 times across 23 separate inspections, most recently on May 26, 2026. For example: Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?

  • Food temperature controlHigher risk

    Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.

    Recorded 24 times across 22 separate inspections, most recently on May 26, 2026. For example: Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 3 times across 3 separate inspections, most recently on March 10, 2025. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

  • Food safety training and certificationLower risk

    Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.

    Recorded 4 times across 4 separate inspections, most recently on May 26, 2026. For example: Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

23 inspections

  1. Risk Management Inspection

    3 infractions

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • As there is no valve for adjusting the flow from the main drain, need to confirm whether majority of flow through the whirlpool is through the skimmers. Was advised some re-piping is going to be done and these valves added.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was at least one weir missing from a skimmer. To be replaced.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • There was some incorrect information on the anti-entrapment plan with regards to the cover that was recently changed. Was advised all the main drain covers are going to be changed out in the near future. Please provide updated anti-entrapment plan when done.
  2. Risk Management Inspection

    3 infractions

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • As there is no valve for adjusting the flow from the main drain, need to confirm whether majority of flow through the whirlpool is through the skimmers. Was advised some re-piping is going to be done and these valves added.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was at least one weir missing from a skimmer. To be replaced.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Some of the pumps for the jets have been changed. Please provide up-dated anti-entrapment plans with new pump information and new flow rates.
  3. Risk Management Inspection

    4 infractions

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • As there is no valve for adjusting the flow from the main drain, need to confirm whether majority of flow through the whirlpool is through the skimmers. Was advised some re-piping is going to be done and these valves added.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Drain cover on bottom of whirlpool to the right of the stair railing (interior portion of whirlpool) was damaged (piece missing). To be replaced with new drain cover (installed according to manufacturer's requirements and in good condition) before public again has access to interior portion of whirlpool; currently is no public access to indoor area as construction still ongoing in indoor pool area and barrier installed between indoor and outdoor portions of the whirlpool.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was at least one weir missing from a skimmer. To be replaced.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Some of the pumps for the jets have been changed. Please provide up-dated anti-entrapment plans with new pump information and new flow rates.
  4. Monitoring Inspection

    3 infractions

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • As there is no valve for adjusting the flow from the main drain, need to confirm whether majority of flow through the whirlpool is through the skimmers. Was advised some re-piping is going to be done and these valves added.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was at least one weir missing from a skimmer. To be replaced.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Some of the pumps for the jets have been changed. Please provide up-dated anti-entrapment plans with new pump information and new flow rates.
  5. Risk Management Inspection

    3 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow rate for the whirlpool was fluctuating between 250-275gpm according to the flow meter during last inspection and today the float appeared stuck at 350gpm. Minimum required flow rate if 361gpm. Please ensure flow meter is working properly and flow rate is maintained between 361gpm and 441gpm.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • As there is no valve for adjusting the flow from the main drain, need to confirm whether majority of flow through the whirlpool is through the skimmer. Recommend using an ultrasonic flow meter to determine flow through skimmers versus main drains.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was at least one weir missing from a skimmer. To be replaced.
  6. Demand Inspection

    5 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample taken on October 27, 2025 had total coliforms present. Treat water to remove contamination. Resample.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Dec.29/25; Sample had missing id label, not tested. Resample.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow rate for the whirlpool was fluctuating between 250-275gpm according to the flow meter during last inspection and today the float appeared stuck at 350gpm. Minimum required flow rate if 361gpm. Please ensure flow meter is working properly and flow rate is maintained between 361gpm and 441gpm.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • As there is no valve for adjusting the flow from the main drain, need to confirm whether majority of flow through the whirlpool is through the skimmer. Recommend using an ultrasonic flow meter to determine flow through skimmers versus main drains.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was at least one weir missing from a skimmer. To be replaced.
  7. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample taken on October 27, 2025 had total coliforms present. Treat water to remove contamination. Resample.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow rate for the whirlpool was fluctuating between 250-275gpm according to the flow meter during last inspection and today the float appeared stuck at 350gpm. Minimum required flow rate if 361gpm. Please ensure flow meter is working properly and flow rate is maintained between 361gpm and 441gpm.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • As there is no valve for adjusting the flow from the main drain, need to confirm whether majority of flow through the whirlpool is through the skimmer. Recommend using an ultrasonic flow meter to determine flow through skimmers versus main drains.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was at least one weir missing from a skimmer. To be replaced.
  8. Risk Management Inspection

    3 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow rate for the whirlpool was fluctuating between 250-275gpm according to the flow meter during last inspection and today the float appeared stuck at 350gpm. Minimum required flow rate if 361gpm. Please ensure flow meter is working properly and flow rate is maintained between 361gpm and 441gpm.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • As there is no valve for adjusting the flow from the main drain, need to confirm whether majority of flow through the whirlpool is through the skimmer. Recommend using an ultrasonic flow meter to determine flow through skimmers versus main drains.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was at least one weir missing from a skimmer. To be replaced.
  9. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample taken on October 6, 2025 had Pseudomonas isolated. Close whirlpool until a Pseudomonas disinfection is done. Resample.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow rate for the whirlpool was fluctuating between 250-275gpm according to the flow meter during last inspection and today the float appeared stuck at 350gpm. Minimum required flow rate if 361gpm. Please ensure flow meter is working properly and flow rate is maintained between 361gpm and 441gpm.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • As there is no valve for adjusting the flow from the main drain, need to confirm whether majority of flow through the whirlpool is through the skimmer. Recommend using an ultrasonic flow meter to determine flow through skimmers versus main drains.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was at least one weir missing from a skimmer. To be replaced.
  10. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted on October 3, 2025 was not tested as it was received by the lab after it had closed for the weekend. New sample to be submitted.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow rate for the whirlpool was fluctuating between 250-275gpm according to the flow meter during last inspection and today the float appeared stuck at 350gpm. Minimum required flow rate if 361gpm. Please ensure flow meter is working properly and flow rate is maintained between 361gpm and 441gpm.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • As there is no valve for adjusting the flow from the main drain, need to confirm whether majority of flow through the whirlpool is through the skimmer. Recommend using an ultrasonic flow meter to determine flow through skimmers versus main drains.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was at least one weir missing from a skimmer. To be replaced.
  11. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample taken on July 15, 2025 had a heterotrophic plate count of 110 cfu/ml. Treat water to remove contamination. Resample.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow rate for the whirlpool was fluctuating between 250-275gpm according to the flow meter during last inspection and today the float appeared stuck at 350gpm. Minimum required flow rate if 361gpm. Please ensure flow meter is working properly and flow rate is maintained between 361gpm and 441gpm.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • As there is no valve for adjusting the flow from the main drain, need to confirm whether majority of flow through the whirlpool is through the skimmer. Recommend using an ultrasonic flow meter to determine flow through skimmers versus main drains.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was at least one weir missing from a skimmer. To be replaced.
  12. Risk Management Inspection

    3 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow rate for the whirlpool was fluctuating between 250-275gpm according to the flow meter during last inspection and today the float appeared stuck at 350gpm. Minimum required flow rate if 361gpm. Please ensure flow meter is working properly and flow rate is maintained between 361gpm and 441gpm.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • As there is no valve for adjusting the flow from the main drain, need to confirm whether majority of flow through the whirlpool is through the skimmer. Recommend using an ultrasonic flow meter to determine flow through skimmers versus main drains.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was at least one weir missing from a skimmer. To be replaced.
  13. Demand Inspection

    6 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • March 7, 2025 water sample was not tested as it was not received by the Lab prior to the Lab closing for the weekend. Resample to be submitted.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine level was measured as 1.82ppm. Combined chlorine level is to be reduced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow rate for the whirlpool was fluctuating between 250-275gpm according to the flow meter. Minimum required flow rate if 361gpm. Please ensure flow rate increased to between 361gpm and 441gpm.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • As there is no valve for adjusting the flow from the main drain, need to confirm whether majority of flow through the whirlpool is through the skimmer. Recommend using an ultrasonic flow meter to determine flow through skimmers versus main drains.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Whirlpool water temperature was measured as 41.9C. Reduce temperature to no more than 40C.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was at least one weir missing from a skimmer. To be replaced.
  14. Demand Inspection

    5 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine level was measured as 1.82ppm. Combined chlorine level is to be reduced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow rate for the whirlpool was fluctuating between 250-275gpm according to the flow meter. Minimum required flow rate if 361gpm. Please ensure flow rate increased to between 361gpm and 441gpm.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • As there is no valve for adjusting the flow from the main drain, need to confirm whether majority of flow through the whirlpool is through the skimmer. Recommend using an ultrasonic flow meter to determine flow through skimmers versus main drains.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Whirlpool water temperature was measured as 41.9C. Reduce temperature to no more than 40C.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There was at least one weir missing from a skimmer. To be replaced.
  15. Risk Management Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow rate for the whirlpool was 350gpm according to the flow meter. Minimum required flow rate if 361gpm. Please ensure flow rate increased to between 361gpm and 441gpm.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • As there is no valve for adjusting the flow from the main drain, need to confirm whether majority of flow through the whirlpool is through the skimmer. Recommend using an ultrasonic flow meter to determine flow through skimmers versus main drains.
  16. Monitoring Inspection

    5 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Chlorine was measured as 0.09ppm. Was advised that dechlor had just been added and too much had accidentally been added.Pool operator adjusted chlorine level to 2.15ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The smaller filter (TR-140) has been bypassed so all flow is going through only the larger filter. Are now exceeding allowable flow rate through the larger filter. New TR-140 filter was just installed; was advised flow to it would be turned on later today.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Skimmer valve to circulation pump is not fully open. Was advised that if the skimmer valve is fully open, air gets into the pump. Need to determine whether majority of flow through the whirlpool is through the skimmer. Recommend using an ultrasonic flow meter to determine flow through skimmers versus main drains.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • There is no clock visible in the pool area to whirlpool users.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter for the jets were not working.Repair/replace flow meters so they are functional and accurate.Some of the weirs were missing from the skimmers. To be replaced.
  17. Demand Inspection

    5 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • May 10/24 water sample was not processed as there was no time of collection on the requisition form and no id# sticker on the bottle. Resample to be taken.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The smaller filter has been bypassed so all flow is going through only the larger filter. Are now exceeding allowable flow rate through the larger filter. Smaller filter needs to be repaired and handling enough of the flow so 12.5gpm/sq.ft is not being exceeded through either filter.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Skimmer valve to circulation pump is not fully open. Keep fully open to maximize water remove from the pool through the skimmers.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • There is no clock visible in the pool area to whirlpool users.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter for the jets were not working.Repair/replace flow meters so they are functional and accurate.Some of the weirs were missing from the skimmers. To be replaced.Some of the weirs were stuck in place. Please ensure all weirs are working properly.
  18. Risk Management Inspection

    4 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The smaller filter has been bypassed so all flow is going through only the larger filter. Are now exceeding allowable flow rate through the larger filter. Smaller filter needs to be repaired and handling enough of the flow so 12.5gpm/sq.ft is not being exceeded through either filter.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Skimmer valve to circulation pump is not fully open. Keep fully open to maximize water remove from the pool through the skimmers.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • There is no clock visible in the pool area to whirlpool users.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter for the jets were not working.Repair/replace flow meters so they are functional and accurate.Some of the weirs were missing from the skimmers. To be replaced.Some of the weirs were stuck in place. Please ensure all weirs are working properly.
  19. Demand Inspection

    5 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted May 3, 2024 was submitted under the wrong access number and there was insufficient information on the requisition form to verify the sample. Resample to be submitted.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The smaller filter has been bypassed so all flow is going through only the larger filter. Are now exceeding allowable flow rate through the larger filter. Smaller filter needs to be repaired and handling enough of the flow so 12.5gpm/sq.ft is not being exceeded through either filter.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Skimmer valve to circulation pump is not fully open. Keep fully open to maximize water remove from the pool through the skimmers.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • There is no clock visible in the pool area to whirlpool users.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter for the jets were not working.Repair/replace flow meters so they are functional and accurate.Some of the weirs were missing from the skimmers. To be replaced.Some of the weirs were stuck in place. Please ensure all weirs are working properly.
  20. Demand Inspection

    5 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample taken and dropped off at lab on March 29/24 when it was closed (for stat holiday) so sample was not tested. Resample to be submitted.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The smaller filter has been bypassed so all flow is going through only the larger filter. Are now exceeding allowable flow rate through the larger filter. Smaller filter needs to be repaired and handling enough of the flow so 12.5gpm/sq.ft is not being exceeded through either filter.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Skimmer valve to circulation pump is not fully open. Keep fully open to maximize water remove from the pool through the skimmers.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • There is no clock visible in the pool area to whirlpool users.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter for the jets were not working.Repair/replace flow meters so they are functional and accurate.Some of the weirs were missing from the skimmers. To be replaced.Some of the weirs were stuck in place. Please ensure all weirs are working properly.
  21. Monitoring Inspection

    4 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Skimmer valve to circulation pump is not fully open. Keep fully open to maximize water remove from the pool through the skimmers.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The smaller filter has been bypassed so all flow is going through only the larger filter. Are now exceeding allowable flow rate through the larger filter. Smaller filter needs to be repaired and handling enough of the flow so 12.5gpm/sq.ft is not being exceeded through either filter.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • There is no clock visible in the pool area to whirlpool users.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Flow meter for the jets were not working.Repair/replace flow meters so they are functional and accurate.Some of the weirs were missing from the skimmers. To be replaced.Some of the weirs were stuck in place. Please ensure all weirs are working properly.
  22. Demand Inspection

    5 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Jan. 5/24 water sample had Pseudomonas isolated. Treat water to remove contamination.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Jan 5/24 water sample had a plate count of 620 cfu/ml. Treat water to remove contamination.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow meter for overall system flow rate was not working. Could not determine the flow rate for the pool.
    • 08. Does food preparation and consumption take place away from the pool?
      • People were consuming pop/coffee while sitting in the whirlpool. A staff advised them this was not allowed at time of inspection but strongly recommend signage be installed advising guests of this. Can have a designated/marked off area for consumption of food/beverages but are not to be consumed while in the pool.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Overall flow meter for the system was not working.Flow meter for the jets were also not working.Repair/replace flow meters so they are functional and accurate.One of the weirs was missing from skimmer (one next to outside stairs into whirlpool). To be replaced.
  23. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Nov.2/23 water sample was not tested as there was no id# on the bottle. Please resample.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow meter for overall system flow rate was not working. Could not determine the flow rate for the pool.
    • 08. Does food preparation and consumption take place away from the pool?
      • People were consuming pop/coffee while sitting in the whirlpool. A staff advised them this was not allowed at time of inspection but strongly recommend signage be installed advising guests of this. Can have a designated/marked off area for consumption of food/beverages but are not to be consumed while in the pool.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Overall flow meter for the system was not working.Flow meter for the jets were also not working.Repair/replace flow meters so they are functional and accurate.One of the weirs was missing from skimmer (one next to outside stairs into whirlpool). To be replaced.