Quality Inn & Suites - Whirlpool
11710 102 Street Grande Prairie AB T8V 7S7 · Aquatic Facility
14 inspections
- Risk Management Inspection
0 infractions
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- A microbiological water sample was submitted to the regional health authority on April 29, 2026.The results indicate the following:Total coliforms – AbsentHeterotrophic Plate Count - 57,000 CFU/MLPseudomonas Aeruginosa – ISOLATEDEnsure the hot tub remains closed until satisfactory results are obtained. Follow instructions mentioned below.A microbiological water sample was submitted to the regional health authority on April 22, 2026. The results indicate the following:Total coliforms – AbsentHeterotrophic Plate Count - <10 CFU/MLPseudomonas Aeruginosa – ISOLATEDThe owner / operator of this pool is requested to immediately conduct the following, namely:1. Close this pool until further notice2. Drain, scrub, disinfect, re-fill, and re-balance this pool.3. Submit a microbiological water re-sample to the regional health authority for laboratory analysis.4. This pool must remain closed until such time that a satisfactory pool water sample has been achieved.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- A microbiological water sample was submitted to the regional health authority on April 29, 2026.The results indicate the following:Heterotrophic Plate Count - 57,000 CFU/MLEnsure HPC is less than 100 CFU/mL.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- A microbiological water sample was submitted to the regional health authority on April 22, 2026. The results indicate the following:Total coliforms – AbsentHeterotrophic Plate Count - <10 CFU/MLPseudomonas Aeruginosa – ISOLATEDThe owner / operator of this pool is requested to immediately conduct the following, namely:1. Close this pool until further notice2. Drain, scrub, disinfect, re-fill, and re-balance this pool.3. Submit a microbiological water re-sample to the regional health authority for laboratory analysis.4. This pool must remain closed until such time that a satisfactory pool water sample has been achieved.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Unsatisfactory water result for sample collected on November 19, 2025:Pseudomonas Aeruginosa: IsolatedEnsure hot tub is closed, drained, cleaned and shock chlorinated. Hot tub must remain closed until a satisfactory result is received.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Pseudomonas Aeruginosa isolated.Ensure hot tub is closed for public use. Clean, shock chlorinate, balance the pool water chemistry and then submit another water sample. Hot tub to remain closed until satisfactory results.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC: 320 CFU/ml.Ensure water is dumped and pool basin is cleaned. Balance water parameters before submitting re-sample this week.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC is noted at 240 CFU/ml.Ensure all water parameters are balanced and maintained and samples are submitted as soon as possible.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC is noted at 220 CFU/ml.Please super chlorinate the pool.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Unsatisfactory water results-Pseudomonas - PresentHPC - 820cfu/mlPlease ensure the hot tub remains closed until all remediation steps are completed and satisfactory laboratory results are received.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?