Skip to content
Loading map…

Ramada by Wyndham Drayton Valley - Swimming Pool

2051 50 Street Drayton Valley AB T7A 1S5 · Aquatic Facility

22 inspections

  1. Monitoring Inspection

    0 infractions

  2. Monitoring Inspection

    0 infractions

  3. Monitoring Inspection

    0 infractions

  4. Monitoring Inspection

    0 infractions

  5. Risk Management Inspection

    0 infractions

  6. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • PHI received notification from the lab for this week's water sample from the main pool, that was collected on May 20, 2025. The results were: - Total Coliforms - ABSENT - HPC 1080 CFU/mLThis is an unsatisfactory result.The operator, contacted the PHI to inform on the actions taken so far.The main pool has been closed to the public and will be shock chlorinated overnight.Once that process is completed - back wash the filter, balance your water chemistry and then the pool can be re-opened to the public.Resample on Tuesday.
  7. Risk Management Inspection

    0 infractions

  8. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on March 25, 2025, yielded the following results:Total Coliforms - NOT DETECTEDHPC 260 cfu/mLThis outcome is not satisfactory.Through email communication and a phone conversation, the operator, Ryan Fynn (General Manager) mentioned that they also super shocked the pool on Wednesday evening because the combined chlorine levels were high due to many families staying over for spring break, who may not have showered before using the pool, resulting in a high bather load. No unusual incidents happened. The staff is currently cleaning the sand filter and will increase the chlorine levels in the pool for several hours, with plans to rebalance and resample on the upcoming Tuesday.
  9. Risk Management Inspection

    0 infractions

  10. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on Feb 4, 2025 had these results: - Total Coliforms - ABSENT - HPC 370 cfu/mLThis is an unsatisfactory result.Through email correspondence, the operator, explained that they had backwashed the filters and shock chlorinated on Feb 6, 2025 and that they will increase chlorine dosage today and re-shock chlorinate the pool tonight ( Feb 7, 2025 ) - these are appropriate response actions for this situation.Resampling will occur next Tuesday Feb 11, 2025.
  11. Monitoring Inspection

    0 infractions

  12. Risk Management Inspection

    0 infractions

  13. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on Dec 17, 2024, had the following results: - Total Coliforms - ABSENT - HPC - 130 CFU/mLThis is an unsatisfactory result.Recommended actions - pool can be used through today. - tonight, once the pool is closed from patron use, you can shock chlorinate overnight, backwash the filter in the morning, re-balance water chemistry and then re-open to the public. - re-sample on Monday (due to the holiday schedule).
  14. Monitoring Inspection

    0 infractions

  15. Monitoring Inspection

    0 infractions

  16. Risk Management Inspection

    0 infractions

  17. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on April 2, 2024 had these results: - Total Coliforms - ABSENT - HPC 120 CFU/mLThis is an unsatisfactory result.Operator performed routine maintenance of this basin and has already shock chlorinated and backwashed the filter, since this sample was taken.Therefore appropriate procedures have already taken place.Submit water sample on Tuesday as usual.
  18. Risk Management Inspection

    0 infractions

  19. Monitoring Inspection

    0 infractions

  20. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Pool water sample collected on Jan 2, 2024, had these results: - Total Coliforms - ABSENT - HPC at 390 CFU/mLThis is an unsatisfactory water report.As discussed, you will be closing the pool and preforming corrective actions.Once corrective actions are completed, the pool water chemistry re-balanced - it can be re-opened to the public.Resample on Tuesday Jan 9, 2024.
  21. Monitoring Inspection

    0 infractions

  22. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined Chlorine is high.The water flow rate for the regular pool is low.Requested to shock chlorinate the pool.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The pool should be vacuumed. Black things were noted at the bottom of the pool.Pool skimmers were full of debris, not well maintained and clean.Requested for some housekeeping and cleaning for the pool basin and skimmers