Skip to content
Loading map…

Ramada by Wyndham Drayton Valley - Swimming Pool

2051 50 Street Drayton Valley AB T7A 1S5 · Aquatic Facility

Inspection summary

Ramada by Wyndham Drayton Valley - Swimming Pool has been inspected 22 times by Alberta Health Services (Environmental Public Health) since January 5, 2024. The most recent inspection, on July 24, 2026, found no infractions.

15 of 22 inspections on record found no infractions at all. In the past 12 months there were 4 inspections with 1 infraction recorded. The higher-risk findings here relate to: Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 7 times across 7 separate inspections, most recently on July 17, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

22 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on July 14, 2026 had the following results: - Total Coliforms - Absent - HPC - 1850 CFU/mLThis is an Unsatisfactory water result.This was discussed with the maintenance man.The main pool will need to be closed immediately, shock chlorinated, back wash filters and re-balance the pool water chemistry - then the pool can be re-opened to the public. Resample next Tuesday.
  3. Monitoring Inspection

    0 infractions

  4. Monitoring Inspection

    0 infractions

  5. Monitoring Inspection

    0 infractions

  6. Monitoring Inspection

    0 infractions

  7. Risk Management Inspection

    0 infractions

  8. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • PHI received notification from the lab for this week's water sample from the main pool, that was collected on May 20, 2025. The results were: - Total Coliforms - ABSENT - HPC 1080 CFU/mLThis is an unsatisfactory result.The operator, contacted the PHI to inform on the actions taken so far.The main pool has been closed to the public and will be shock chlorinated overnight.Once that process is completed - back wash the filter, balance your water chemistry and then the pool can be re-opened to the public.Resample on Tuesday.
  9. Risk Management Inspection

    0 infractions

  10. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on March 25, 2025, yielded the following results:Total Coliforms - NOT DETECTEDHPC 260 cfu/mLThis outcome is not satisfactory.Through email communication and a phone conversation, the operator, Ryan Fynn (General Manager) mentioned that they also super shocked the pool on Wednesday evening because the combined chlorine levels were high due to many families staying over for spring break, who may not have showered before using the pool, resulting in a high bather load. No unusual incidents happened. The staff is currently cleaning the sand filter and will increase the chlorine levels in the pool for several hours, with plans to rebalance and resample on the upcoming Tuesday.
  11. Risk Management Inspection

    0 infractions

  12. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on Feb 4, 2025 had these results: - Total Coliforms - ABSENT - HPC 370 cfu/mLThis is an unsatisfactory result.Through email correspondence, the operator, explained that they had backwashed the filters and shock chlorinated on Feb 6, 2025 and that they will increase chlorine dosage today and re-shock chlorinate the pool tonight ( Feb 7, 2025 ) - these are appropriate response actions for this situation.Resampling will occur next Tuesday Feb 11, 2025.
  13. Monitoring Inspection

    0 infractions

  14. Risk Management Inspection

    0 infractions

  15. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on Dec 17, 2024, had the following results: - Total Coliforms - ABSENT - HPC - 130 CFU/mLThis is an unsatisfactory result.Recommended actions - pool can be used through today. - tonight, once the pool is closed from patron use, you can shock chlorinate overnight, backwash the filter in the morning, re-balance water chemistry and then re-open to the public. - re-sample on Monday (due to the holiday schedule).
  16. Monitoring Inspection

    0 infractions

  17. Monitoring Inspection

    0 infractions

  18. Risk Management Inspection

    0 infractions

  19. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on April 2, 2024 had these results: - Total Coliforms - ABSENT - HPC 120 CFU/mLThis is an unsatisfactory result.Operator performed routine maintenance of this basin and has already shock chlorinated and backwashed the filter, since this sample was taken.Therefore appropriate procedures have already taken place.Submit water sample on Tuesday as usual.
  20. Risk Management Inspection

    0 infractions

  21. Monitoring Inspection

    0 infractions

  22. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Pool water sample collected on Jan 2, 2024, had these results: - Total Coliforms - ABSENT - HPC at 390 CFU/mLThis is an unsatisfactory water report.As discussed, you will be closing the pool and preforming corrective actions.Once corrective actions are completed, the pool water chemistry re-balanced - it can be re-opened to the public.Resample on Tuesday Jan 9, 2024.
Own this business? Add a badge to your website