Ramada by Wyndham Drayton Valley - Whirlpool

2051 50 Street Drayton Valley AB T7A 1S5 · Aquatic Facility

Inspection summary

Ramada by Wyndham Drayton Valley - Whirlpool has been inspected 17 times by Alberta Health Services (Environmental Public Health) since January 5, 2024. The most recent inspection, on August 25, 2026, found no infractions.

10 of 17 inspections on record found no infractions at all. In the past 12 months there were 4 inspections with 1 infraction recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 7 times across 6 separate inspections, most recently on August 12, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded once on October 8, 2024. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

17 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological water sample result from sample collected on 2026-08-11 detected the presence of Pseudomonas aeruginosa. Pool operator confirmed that the whirlpool was drained, scrubbed/cleaned, refilled, and pool chemistry was balanced. Please submit another bacteriological water sample to confirm bacteriological water quality following these procedures.
  3. Monitoring Inspection

    0 infractions

  4. Monitoring Inspection

    0 infractions

  5. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Whirlpool volume: 2404 gallonsFlow rate: 65 gpmTherefore, turnover period = 37 minutesThis is an unsatisfactory turnover period. According to our records, this whirlpool was constructed in or around 2007, and therefore (based on the whirlpool's volume) must adhere to our standard of a 20-minute turnover rate. In order to achieve this, your flow rate should be approximately 120 gpm.
  6. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample taken on August 12, 2025, showed the subsequent results:- Total Coliforms - Not Detected- Pseudomonas - Isolated.- HPC less than 10 cfu/mL
  7. Monitoring Inspection

    0 infractions

  8. Risk Management Inspection

    0 infractions

  9. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample taken on March 25, 2025 showed the subsequent results:- Total Coliforms - Not Detected- Pseudomonas - Isolated.- HPC 40 cfu/mLThrough email exchange and a phone conversation with the general manager, Ryan Fynn, he stated that the hot tub has been closed for the day, super shock chlorination completed overnight on Wednesday. They are currently backwashing, cleaning sand filters, and will re-shock it again, Afterward, they will drain, rebalance, and resample it on the upcoming Tuesday. Adhering to the Pseudomonas Response guidelines.
  10. Risk Management Inspection

    0 infractions

  11. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The water sample collected on Feb 4, 2025 had the following results: - Total Coliforms - Absent - Pseudomonas - ISOLATED - HPC 220 cfu/mLThis is an unsatisfactory result.This was discussed with the operator, by email.Follow the Pseudomonas Response protocols. Once completed and the whirlpool water has been re-balanced, you can re-open to the public.
  12. Monitoring Inspection

    0 infractions

  13. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • PHI test results were:Combined chlorine 1.42 ppmAlkalinity 51 Correction:Combined chlorine is too high, and Alkalinity is lower than the required parameters. Requested operator to shock chlorinate it overnight and balance the pool.
  14. Monitoring Inspection

    0 infractions

  15. Risk Management Inspection

    0 infractions

  16. Monitoring Inspection

    0 infractions

  17. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Whirlpool water sample collected on Jan 2, 2024, had these results: - Total Coliforms - ABSENT - Pseudomonas - ISOLATED - HPC at 1020 CFU/mLThis is an unsatisfactory report.The whirlpool shall be closed immediately and follow the instructions for the Pseudomonas aeruginosa Information Sheet. Once these steps have been completed, water chemistry re-balanced - the whirlpool can be re-opened to the public.Resample on Tuesday Jan 9, 2024.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • This water sample also exceeded the safe parameter for HPC.Your result was 1020 CFU/mL and the maximum allowed is <100 CFU/mL.Following the instructions for the Pseudomonas response will also correct the concern with HPC.