Skip to content
Loading map…

Reborn Health & Beauty Centre Ltd.

138 - 9700 105 Avenue NW Edmonton AB T6V 1B1T5H 4J1 · Personal Services

3 inspections

  1. Risk Management Inspection

    0 infractions

  2. Risk Management Inspection

    1 infraction

    • 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
      • Received pictures from the operator showing that cleint records are maintained.Lot number or sterility assurance documentation number is still misisng.Make sure to include the indicated document or lot number with client records.Previous Inspection: Operator was not maintaining the client record.Client records must be stored for at least two years.Include following details in the client records: Client name, contact information, service provided, date and description of service provided and sterility assurance documentation.
  3. Monitoring Inspection

    5 infractions

    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • Templates for Facility specific written procedures specific to the business were provided during the inspection:1) Written procedures for skin cleansing.2) Written procedures for applying antiseptic to skin.3) Written procedures for Client care in case of Accidental Skin cut and punctures.
    • 10. Is cleansing and antisepsis of skin and mucous membrane performed in accordance to written procedures and are suitable products being used?
      • Operator mentioned that skin toner is used on client skin before performing needling procedures.Discussed to use an antiseptic before performing and skin puncturing.Antiseptic with NPN number was available onsite.
    • 11. Is post-service care provided by personal service workers following any personal service or accident where a client's skin or mucous membrane is cut or punctured during a personal service, or when energy-emitting equipment is used?
      • Operator discussed that post service care are verbally provided to clients.Operator was asked to ensure that written instructions are provided to the clients either electronically or by paper form.Operator confirmed to providing the written instructions to the clients after microneedling procedure.
    • 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
      • Operator was not maintaining the client record.Client records must be stored for at least two years.Include following details in the client records: Client name, contact information, service provided, date and description of service provided and sterility assurance documentation.
    • 20. Is reusable equipment disinfected properly?
      • Observation was made that operator is using comedone/loop extractors for facial services.Operator mentioned that they are cleaned and disinfected using antiseptic product.Please note that comedone/loop extractors are considered semi-critical equipment and must be disinfected using at least High-Level Disinfectant.Obtain the HLD and follow manufacturers instructions for the reuse period and dilution expiry date of HLD.**Operator confirmed that the HLD will be discarded after each use, hence routine testing is not required.