Redefine Laser and Electrolysis Clinic
11206 76 Avenue NW Edmonton AB T6G 0K1 · Personal Services
3 inspections
- Risk Management Inspection
1 infraction
- 20. Is reusable equipment disinfected properly?
- Preempt CS20 was not used according to the manufacturer's instructions for use (MIFU). The solution was not changed every 14 days.Please ensure Preempt CS20 is changed 14 days after it is first poured out and used in the disinfectant tray.When using the HLD test log, cross out any day that the solution is not used.
- 20. Is reusable equipment disinfected properly?
- Risk Management Inspection
0 infractions
- Initial Inspection
8 infractions
- 02. Has the operator notified the RHA of the existence of a personal service business, including contact and location information, as well as all personal services currently offered or new personal services that will be offered for facilities and/or special events?
- The owner of the personal service business did not submit a notification about the business to the Alberta Health Services. It was submitted during the inspection.
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- No written procedures for skin cleansing prior to services and antiseptic use were available.
- 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
- Sterility assurance documentation for sterile equipment was not retained with the clients' records. Ensure that sterility assurance documentation for all critical equipment used during services is retained with clients' forms.
- 20. Is reusable equipment disinfected properly?
- No test strips were available to test the concentration of high-level disinfectant. Obtain the appropriate strips.
- 20. Is reusable equipment disinfected properly?
- No records of testing of high-level disinfectant were available, and no testing of disinfectant has been conducted as required.
- 21. Is equipment that is intended to be sterile maintained sterile at the point of use?
- Some needles did not have appropriate sterility assurance documentation.
- 26. Are cosmetic products appropriate for their intended use and being handled properly?
- Some cosmetic products did not have appropriate labels. It was addressed during the inspection. Ensure that all cosmetic products have appropriate labels.
- 33. Are general nuisance conditions, other than those noted in other violations, being prevented at this personal services facility (Non-Critical)?
- Mirror was present in the room (reflective surface) used for laser services.
- 02. Has the operator notified the RHA of the existence of a personal service business, including contact and location information, as well as all personal services currently offered or new personal services that will be offered for facilities and/or special events?