Skip to content
Loading map…

Reset Hydrotherapy - Cold Tub 403-1

600 - 8888 Country Hills Boulevard NW Calgary AB T3G 5T4 · Aquatic Facility

8 inspections

  1. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on 12/12/2025 was rejected due to non-urgent sample received during the weekend/holiday without approval.Resample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured at 53 mg/L.-Maintain alkalinity between 60-180 mg/L
  2. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity measured at 53 mg/L.-Maintain alkalinity between 60-180 mg/L
  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample collected on 15/08/2025 tested positive for Total Coliforms.Treat and resample.
  5. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on 07/03/2025, at 08:33 and received on 08/03/2025, at 8:37, was not tested due to non-urgent sample received during the weekend/holiday without approval.
  6. Initial Inspection

    0 infractions

  7. Demand Inspection

    0 infractions

  8. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC - 7440 CFU/MLTreat and Resample