Reset Hydrotherapy - Cold Tub 403-4
600 - 8888 Country Hills Boulevard NW Calgary AB T3G 5T4 · Aquatic Facility
Inspection summary
Reset Hydrotherapy - Cold Tub 403-4 has been inspected 7 times by Alberta Health Services (Environmental Public Health) since December 19, 2024. The most recent inspection, on December 15, 2025, recorded 2 infractions.
1 of 7 inspections on record found no infractions at all. In the past 12 months there were 2 inspections with 3 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.
The number of infractions per inspection has stayed roughly the same over time.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 6 times across 5 separate inspections, most recently on December 15, 2025. For example:
Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
Chemicals and toxic substancesHigher risk
Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.
Recorded 4 times across 4 separate inspections, most recently on December 15, 2025. For example:
Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
7 inspections
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on 12/12/2025 was rejected due to non-urgent sample received during the weekend/holiday without approval.Resample.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity measured low at 40 ppm. - Maintain Total Alkalinity between 60-180 ppm.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity measured low at 40 ppm. - Maintain Total Alkalinity between 60-180 ppm.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on 07/03/2025 08:46 and received on 08/03/2025 8:37, was not tested due to non-urgent sample received during the weekend/holiday without approval.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Initial Inspection
0 infractions
- Demand Inspection
2 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Free chlorine level was 0.28 ppm. - Maintain free chlorine at 1 ppm or higher.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automated monitoring system pH reading was 7.5 and manual reading was 6.85. - Ensure that manual and automated system readings are consistent.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC 9000 CFU/MLTreat and Resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC 9000 CFU/MLTreat and Resample.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Free chlorine level was 0.28 ppm. - Maintain free chlorine at 1 ppm or higher.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Automated monitoring system pH reading was 7.5 and manual reading was 6.85. - Ensure that manual and automated system readings are consistent.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?