Ryley Swimming Pool - Hot Tub

5215 52 Avenue Ryley AB T0B 4A0 · Aquatic Facility

21 inspections

  1. Risk Management Inspection

    0 infractions

  2. Monitoring Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Measurements were taken with the Pool Test 2.0 equipment and readings of the whirlpool as follows:1) Free Chlorine: 3.47 ppm - in compliance with the minimum 2.0 ppm for water temperature >30 degrees C.2) pH: 7.85 - not in compliance. Please ensure this level is reduced to 7.6 and ideally should be around 7.2.
  3. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TOTAL ALKALINITIY FOR HOT TUB:1) Measurement was taken with the Pool Lab 2.0 kit and reading was 20 ppm for the hot tub which is not in compliance. Readings for total alkalinity should be in the range of 60 - 180 ppm and follow-up should be carried out by the Pool Manager to increase the alkalinity to meet the above requirements.2) Ensure Alkalinity readings of both the hot tub and main pool are taken on a weekly basis.SEPTEMBER 10, 2025:Since the hot tub was not in operation at the time of inspection, the readings for Total Alkalinity, pH, and free chlorine were not measured with the Pool Test Kit.Subsequently, will need to be measured at a later date.
  4. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TOTAL ALKALINITIY FOR HOT TUB:1) Measurement was taken with the Pool Lab 2.0 kit and reading was 20 ppm for the hot tub which is not in compliance. Readings for total alkalinity should be in the range of 60 - 180 ppm and follow-up should be carried out by the Pool Manager to increase the alkalinity to meet the above requirements.2) Ensure Alkalinity readings of both the hot tub and main pool are taken on a weekly basis.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • CLOCK REQUIREMENT FOR HOT TUB:Currently, the only clock located in the pool deck area is on the opposite end of the pool and furthest away from the hot tub.Patrons must be able to determine the time spent in the hot tub and subsequently a clock (preferably digital) should be wall mounted beside/near the hot tub.This was discussed with the Pool Manager during the assessment.
  5. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological water sample collected from the hot tub on August 20, 2025 was found present for Total Coliforms and is subsequently unsatisfactory. Result was made available to our Department on August 22, 2025 and relayed to the Manager for her follow-up action.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TOTAL ALKALINITIY FOR HOT TUB:1) Measurement was taken with the Pool Lab 2.0 kit and reading was 20 ppm for the hot tub which is not in compliance. Readings for total alkalinity should be in the range of 60 - 180 ppm and follow-up should be carried out by the Pool Manager to increase the alkalinity to meet the above requirements.2) Ensure Alkalinity readings of both the hot tub and main pool are taken on a weekly basis.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • CLOCK REQUIREMENT FOR HOT TUB:Currently, the only clock located in the pool deck area is on the opposite end of the pool and furthest away from the hot tub.Patrons must be able to determine the time spent in the hot tub and subsequently a clock (preferably digital) should be wall mounted beside/near the hot tub.This was discussed with the Pool Manager during the assessment.
  6. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TOTAL ALKALINITIY FOR HOT TUB:1) Measurement was taken with the Pool Lab 2.0 kit and reading was 20 ppm for the hot tub which is not in compliance. Readings for total alkalinity should be in the range of 60 - 180 ppm and follow-up should be carried out by the Pool Manager to increase the alkalinity to meet the above requirements.2) Ensure Alkalinity readings of both the hot tub and main pool are taken on a weekly basis.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • CLOCK REQUIREMENT FOR HOT TUB:Currently, the only clock located in the pool deck area is on the opposite end of the pool and furthest away from the hot tub.Patrons must be able to determine the time spent in the hot tub and subsequently a clock (preferably digital) should be wall mounted beside/near the hot tub.This was discussed with the Pool Manager during the assessment.
  7. Monitoring Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological water sample collected on July 22, 2025 was found present for Total Coliforms and is subsequently unsatisfactory.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TOTAL ALKALINITIY FOR HOT TUB:1) Measurement was taken with the Pool Lab 2.0 kit and reading was 20 ppm for the hot tub which is not in compliance. Readings for total alkalinity should be in the range of 60 - 180 ppm and follow-up should be carried out by the Pool Manager to increase the alkalinity to meet the above requirements.2) Ensure Alkalinity readings of both the hot tub and main pool are taken on a weekly basis.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • CLOCK REQUIREMENT FOR HOT TUB:Currently, the only clock located in the pool deck area is on the opposite end of the pool and furthest away from the hot tub.Patrons must be able to determine the time spent in the hot tub and subsequently a clock (preferably digital) should be wall mounted beside/near the hot tub.This was discussed with the Pool Manager during the assessment.
  8. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological water sample collected on July 22, 2025 was found present for Total Coliforms and is subsequently unsatisfactory.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TOTAL ALKALINITIY FOR HOT TUB:1) Measurement was taken with the Pool Lab 2.0 kit and reading was 20 ppm for the hot tub which is not in compliance. Readings for total alkalinity should be in the range of 60 - 180 ppm and follow-up should be carried out by the Pool Manager to increase the alkalinity to meet the above requirements.2) Ensure Alkalinity readings of both the hot tub and main pool are taken on a weekly basis.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • CLOCK REQUIREMENT FOR HOT TUB:Currently, the only clock located in the pool deck area is on the opposite end of the pool and furthest away from the hot tub.Patrons must be able to determine the time spent in the hot tub and subsequently a clock (preferably digital) should be wall mounted beside/near the hot tub.This was discussed with the Pool Manager during the assessment.
  9. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TOTAL ALKALINITIY FOR HOT TUB:1) Measurement was taken with the Pool Lab 2.0 kit and reading was 20 ppm for the hot tub which is not in compliance. Readings for total alkalinity should be in the range of 60 - 180 ppm and follow-up should be carried out by the Pool Manager to increase the alkalinity to meet the above requirements.2) Ensure Alkalinity readings of both the hot tub and main pool are taken on a weekly basis.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • CLOCK REQUIREMENT FOR HOT TUB:Currently, the only clock located in the pool deck area is on the opposite end of the pool and furthest away from the hot tub.Patrons must be able to determine the time spent in the hot tub and subsequently a clock (preferably digital) should be wall mounted beside/near the hot tub.This was discussed with the Pool Manager during the assessment.
  10. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Resample result collected from the hot tub on June 30, 2025 was now positive for Pseudomonas aeruginosa and subsequently not in compliance with bacterial pool standards.Total Coliforms count was ABSENT and subsequently in compliance.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Heterotrophic Plate Count (HPC) of 460 which exceeds the maximum limit of 100 or less for aquatic facilities.Hot tub should be drained, cleaned, disinfected, refilled, and then resampled next Wednesday July 2, 2025 to confirm the HPC has been properly addressed and lowered to <100 and ideally < 10.JULY 2, 2025:Resample collected from the hot tub on June 30, 2025 revealed a Heterotrophic Plate Count (HPC) of 2430 which is a significant increase from the previous result of 460.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TOTAL ALKALINITIY FOR HOT TUB:1) Measurement was taken with the Pool Lab 2.0 kit and reading was 20 ppm for the hot tub which is not in compliance. Readings for total alkalinity should be in the range of 60 - 180 ppm and follow-up should be carried out by the Pool Manager to increase the alkalinity to meet the above requirements.2) Ensure Alkalinity readings of both the hot tub and main pool are taken on a weekly basis.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • CLOCK REQUIREMENT FOR HOT TUB:Currently, the only clock located in the pool deck area is on the opposite end of the pool and furthest away from the hot tub.Patrons must be able to determine the time spent in the hot tub and subsequently a clock (preferably digital) should be wall mounted beside/near the hot tub.This was discussed with the Pool Manager during the assessment.
  11. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Heterotrophic Plate Count (HPC) of 460 which exceeds the maximum limit of 100 or less for aquatic facilities.Hot tub should be drained, cleaned, disinfected, refilled, and then resampled next Wednesday July 2, 2025 to confirm the HPC has been properly addressed and lowered to <100 and ideally < 10.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TOTAL ALKALINITIY FOR HOT TUB:1) Measurement was taken with the Pool Lab 2.0 kit and reading was 20 ppm for the hot tub which is not in compliance. Readings for total alkalinity should be in the range of 60 - 180 ppm and follow-up should be carried out by the Pool Manager to increase the alkalinity to meet the above requirements.2) Ensure Alkalinity readings of both the hot tub and main pool are taken on a weekly basis.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • CLOCK REQUIREMENT FOR HOT TUB:Currently, the only clock located in the pool deck area is on the opposite end of the pool and furthest away from the hot tub.Patrons must be able to determine the time spent in the hot tub and subsequently a clock (preferably digital) should be wall mounted beside/near the hot tub.This was discussed with the Pool Manager during the assessment.
  12. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TOTAL ALKALINITIY FOR HOT TUB:1) Measurement was taken with the Pool Lab 2.0 kit and reading was 20 ppm for the hot tub which is not in compliance. Readings for total alkalinity should be in the range of 60 - 180 ppm and follow-up should be carried out by the Pool Manager to increase the alkalinity to meet the above requirements.2) Ensure Alkalinity readings of both the hot tub and main pool are taken on a weekly basis.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • CLOCK REQUIREMENT FOR HOT TUB:Currently, the only clock located in the pool deck area is on the opposite end of the pool and furthest away from the hot tub.Patrons must be able to determine the time spent in the hot tub and subsequently a clock (preferably digital) should be wall mounted beside/near the hot tub.This was discussed with the Pool Manager during the assessment.
  13. Risk Management Inspection

    0 infractions

  14. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Total Coliforms present in hot tub - water sample was collected on December 10, 2024.Pseudomonas and HPC are still pending at this time and should be known by Friday December 13, 2024.Pause operations of hot tub and proceed to draining, scrubbing, sanitizing, refilling, and resampling by next Tuesday December 17, 2024.
  15. Monitoring Inspection

    0 infractions

  16. Risk Management Inspection

    0 infractions

  17. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Heterotrophic Plate Count (HPC) of 170 is over the required limit of 100 or less for aquatic facilities and ideally should always be less than 10.Requires follow-up action and then resampling on Tuesday April 23, 2024.
  18. Risk Management Inspection

    0 infractions

  19. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Total Coliforms present in the HOT TUB component at Ryley Swimming Pool.
  20. Demand Inspection

    0 infractions

  21. Monitoring Inspection

    1 infraction

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • New anti-entrapment covers for the suction outlets (2) in the hot tub component will tentatively be installed sometime next week.The hot tub was originally built in 2016 and normally the anti-entrapment covers for hot tubs are good for 5 years so new covers are required to replace the existing ones.