Skip to content
Loading map…

Ryna's Nails

6-40 Bristol Rd., E Mississauga L4Z 3K8 · Manicure / Pedicure

Inspection summary

Ryna's Nails has been inspected 3 times by Peel Public Health (Region of Peel) since July 8, 2025. The most recent inspection, on March 17, 2026, recorded 3 infractions.

1 of 3 inspections on record found no infractions at all. In the past 12 months there was 1 inspection with 3 infractions recorded. The higher-risk findings here relate to: Food source, labelling and allergens and Protecting food from contamination.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for clients. In personal service settings like salons, spas and tattoo studios, higher-risk findings are the ones that could spread infection from one client to the next, through broken skin, blood or instruments that were not properly cleaned and sterilized.

  • Food source, labelling and allergensHigher risk

    Products used on clients must come from approved sources, stay in their original labelled containers and be thrown out when they are expired or contaminated. Unlabelled products make it impossible to know what a client is being exposed to.

    Recorded 2 times across 2 separate inspections, most recently on March 17, 2026. For example: Did operator discard single use equipment immediately after each use?

  • Protecting food from contaminationHigher risk

    Clean and used instruments, towels and supplies must be kept apart, and products such as wax, creams and inks must be dispensed so they cannot be contaminated between clients (no double-dipping). Mixing clean and dirty items is a direct route for infection.

    Recorded once on July 8, 2025. For example: Did operator store and dispense products in a manner to prevent contamination?

  • Equipment and utensilsLower risk

    Instruments, chairs, tables and footbaths must be made of materials that can be cleaned, kept in good repair and stored so they stay clean. Single-use items such as nail files, buffers, razors and needles must be thrown away after each client.

    Recorded 4 times across 2 separate inspections, most recently on March 17, 2026. For example: Did operator maintain setting and work surfaces in a safe and sanitary condition?

About this data

These results come from Peel Public Health (Region of Peel), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

3 inspections

  1. Required

    3 infractions

    • Did operator maintain setting and work surfaces in a safe and sanitary condition?
    • Did operator discard single use equipment immediately after each use?
      • Discard single use equipment immediately after use.
      • Ensure that all equipment designed for single use or made of a material that does not withstand cleaning and disinfection or sterilization is discarded immediately after use (e.g., nail files, buffer blocks, gloves, sponges, applicator sticks, ear piercing adapters).
    • Did operator maintain reusable equipment in good repair and sanitary condition?
      • Store cleaned and disinfected equipment in a sanitary condition.
  2. Follow-up

    0 infractions

  3. Required

    4 infractions

    • Did operator discard single use equipment immediately after each use?
      • Discard single use equipment immediately after use.
      • Ensure that all equipment designed for single use or made of a material that does not withstand cleaning and disinfection or sterilization is discarded immediately after use (e.g., nail files, buffer blocks, gloves, sponges, applicator sticks, ear piercing adapters).
    • Did operator store and dispense products in a manner to prevent contamination?
      • Dispense products (e.g., creams, oils, ointments, gels, wax and skin antiseptics) in a manner to prevent contamination.
      • Store products in a manner to prevent contamination.
      • Ensure products are not topped up with fresh product (e.g., do not add new solution to the current solution). If a reusable container is used, it must be emptied, cleaned, disinfected, rinsed, and dried before refilling.
      • Manicure/pedicure: Dispense products (e.g., paraffin wax, nail gels/powders) in a manner to prevent contamination.
    • Did operator properly clean reusable equipment?
      • Clean reusable equipment after use on a client to prevent disease transmission.
      • Provide and use cleaning supplies (e.g., scrub brush, detergent) and ensure they are easily accessible.
      • Clean reusable equipment with a scrub brush and detergent.
      • If immediate cleaning is not possible, soak dirty reusable equipment in a container filled with water and detergent.
    • Did operator properly disinfect equipment and surfaces?
      • Disinfect reusable equipment after use on a client to prevent disease transmission.
      • Do not spray or wipe equipment and surfaces with 70-90% alcohol. Alcohol evaporates quickly and will not reach the 10 minute contact time. Equipment must be fully immersed in the alcohol.
      • Fully immerse equipment in 70-90% alcohol for 10 minutes and then discard the alcohol. Do not re-use the alcohol. When soaking equipment, new alcohol must be used for each batch of equipment.
      • Pedicure basin with single use disposable liner: Clean the basin with detergent, water and scrub brush after every use. Clean and low level disinfect at the end of the day. If the liner tears or breaks while in use, clean and intermediate level disinfect the basin immediately after use. If a magnetic jet cover is used in the spa water, it must be cleaned and intermediate level disinfected after every use. (Show More)
      • High-level disinfectant: Mix 125 ml (½ cup) of 5.25% bleach with 1 L (4 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 10 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • High-level disinfect equipment such as grater-style foot files, comedone extractor with loops on both ends, and diamond microdermabrasion tips.