Skip to content
Loading map…

Saddletowne YMCA - Whirlpool

7556 Falconridge Boulevard NE Calgary AB T3J 0C9 · Aquatic Facility

5 inspections

  1. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Alkalinity tested at 37 and 38 mg/L.-Ensure to maintain alkalinity between 60-180 mg/L.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • The Anti-entrapment plan available on-site identified that drain cover expiry date was in 2020. Operator has evidence that the covers have been replaced since then, but the plan has not been updated.- Provide updated anti-entrapment plan.- Ensure anti-entrapment plans are always updated and maintained.
  2. Monitoring Inspection

    0 infractions

  3. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • **Ongoing Violation** the flow meter was not operational.REQUIREMENT: Repair or replace the flow meter. Ensure the flow rate is at least 188 USGPM to meet required turnover rates while not exceeding maximum filtration rates.
  4. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on December 22nd was not processed. According to the laboratory, the date/time of sample collection was later than the date and time of receipt. The date provided was December 23rd.REQUIREMENT: Ensure the correct date/time of collection is recorded on the requisition form.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Last inspection, it was noted that: "The flow was measured to be 168 USPGM, which is still more than 20 minutes."This inspection, the flow meter was not operational.REQUIREMENT: Repair or replace the flow meter. Increase the flow rate to at least 188 USGPM to meet required turnover rates while not exceeding maximum filtration rates.
  5. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The most recent water sample was not processed due to being received 24 hours after collection.The wrong date of 'November 11' appears to have been mistakenly added.REQUIREMENT: Submit another water sample and ensure the correct date and time of collection are written down.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Last inspection, it was noted that: "The flow was measured to be 168 USPGM, which is still more than 20 minutes."This inspection, the flow meter was not operational.REQUIREMENT: Repair or replace the flow meter. Increase the flow rate to at least 188 USGPM to meet required turnover rates while not exceeding maximum filtration rates.