Sandman Hotel Edmonton West - Whirlpool
17635 Stony Plain Road NW Edmonton AB T5S 1E3 · Aquatic Facility
64 inspections
- Demand Inspection
1 infraction
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Chlorine was too low. Operator adjusted the set point to increase chlorine to >2.0ppm. Send updated chemical parameters.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample result collected on May. 7, 2026, was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample result collected on Mar. 19, 2026, was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample result collected on Mar. 3, 2026, was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- the sample 26EN-044E00041 submitted on February 13, 2026, was unsatisfactory: Pseudomonas aeruginosa was isolated and HPC was 130.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- the sample 26EN-044E00041 submitted on February 13, 2026, was unsatisfactory: Pseudomonas aeruginosa was isolated and HPC was 130.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample result collected on Jan. 29, 2026, was unsatisfactory. Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample result collected on Jan. 29, 2026, was unsatisfactory. HPC >100 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample submitted on 18 Nov 2025 was satisfactory
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
5 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on November 6, 2025, was unsatisfactory: Total Coliform present. Pseudomonas issolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on 13/11/2025 was unsatisfactory: Pseudomonas aeruginosa isolated, Total Coliform present. This is the second consecutive unsatisfactory result. Operator contacted and instructed to close the whirlpool and take treatment action immediately. A satisfactory result will be required before the whirlpool basin can be reopened.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- the sample 25EN-310E00582 submitted on November 6, 2025, was unsatisfactory: Total coliforms present, Pseudomonas aeruginosa isolated and HPC over 57000.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 13/11/2025 was unsatisfactory: HPC >57000CFU/mL. This is the second consecutive unsatisfactory result. Operator contacted and instructed to close the pool and take treatment action immediately. A satisfactory result will be required before the pool basin can be reopened.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine levels (2.88ppm) were higher than the free chlorine levels (1.74ppm). Please ensure combined chlorine is maintained as low as possible to maximize bath comfort
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on November 6, 2025, was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced. Updated on November 10, 2025:the sample 25EN-310E00582 submitted on November 6, 2025, was unsatisfactory: Total coliforms present, Pseudomonas aeruginosa isolated and HPC over 57000.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- the sample 25EN-310E00582 submitted on November 6, 2025, was unsatisfactory: Total coliforms present, Pseudomonas aeruginosa isolated and HPC over 57000.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine levels (2.88ppm) were higher than the free chlorine levels (1.74ppm). Please ensure combined chlorine is maintained as low as possible to maximize bath comfort
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on November 6, 2025, was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine levels (2.88ppm) were higher than the free chlorine levels (1.74ppm). Please ensure combined chlorine is maintained as low as possible to maximize bath comfort
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine levels (2.88ppm) were higher than the free chlorine levels (1.74ppm). Please ensure combined chlorine is maintained as low as possible to maximize bath comfort
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample collected on 23/10/2025 was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample collected on 23/10/2025 was unsatisfactory: HPC >100 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine levels (2.88ppm) were higher than the free chlorine levels (1.74ppm). Please ensure combined chlorine is maintained as low as possible to maximize bath comfort
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine levels (2.88ppm) were higher than the free chlorine levels (1.74ppm). Please ensure combined chlorine is maintained as low as possible to maximize bath comfort
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on October 9, 2025, was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on October 9, 2025, was unsatisfactory: HPC >5700 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample result submitted on 03/07/2025 was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The sample 25EN-192E00081 submitted on July 11, 2025, was unsatisfactory: Pseudomonas aeruginosa was isolated. The previous sample was also unsatisfactory (Pseudomonas aeruginosa isolated and HPC 190).
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample result submitted on 03/07/2025 was unsatisfactory: HPC >100 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The sample 25EN-192E00081 submitted on July 11, 2025, was unsatisfactory: Pseudomonas aeruginosa was isolated. The previous sample was also unsatisfactory (Pseudomonas aeruginosa isolated and HPC 190).
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample result submitted on 03/07/2025 was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample result submitted on 03/07/2025 was unsatisfactory: HPC >100 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The suction outlet covers are not assessed weekly to ensure they are secure. If the basin is not being drained that week, the jet pump must be turned off to adequately observe the suction outlet covers.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample result submitted on 03/07/2025 was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample result submitted on 03/07/2025 was unsatisfactory: HPC >100 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The suction outlet covers are not assessed weekly to ensure they are secure. If the basin is not being drained that week, the jet pump must be turned off to adequately observe the suction outlet covers.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The suction outlet covers are not assessed weekly to ensure they are secure. If the basin is not being drained that week, the jet pump must be turned off to adequately observe the suction outlet covers.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- June 12, 2025, water sample not processed due to excessive levels of chlorine.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- June 19, 2025, water sample not processed due to excessive levels of chlorine.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The suction outlet covers are not assessed weekly to ensure they are secure. If the basin is not being drained that week, the jet pump must be turned off to adequately observe the suction outlet covers.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- June 12, 2025, water sample not processed due to excessive levels of chlorine.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The suction outlet covers are not assessed weekly to ensure they are secure. If the basin is not being drained that week, the jet pump must be turned off to adequately observe the suction outlet covers.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The suction outlet covers are not assessed weekly to ensure they are secure. If the basin is not being drained that week, the jet pump must be turned off to adequately observe the suction outlet covers.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- the sample 25EN-150E00082 submitted on May 29, 2025, was unsatisfactory: Pseudomonas aeruginosa was isolated. The previous sample submitted on May 22, 2025, was satisfactory.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The suction outlet covers are not assessed weekly to ensure they are secure. If the basin is not being drained that week, the jet pump must be turned off to adequately observe the suction outlet covers.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on May 6, 2025, was unsatisfactory: HPC 590 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The suction outlet covers are not assessed weekly to ensure they are secure. If the basin is not being drained that week, the jet pump must be turned off to adequately observe the suction outlet covers.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on May 6, 2025, was unsatisfactory: HPC 590 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample result collected on 01/05/2025 was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 03/04/2025 was unsatisfactory: HPC >100 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on April 9, 2025, was unsatisfactory: HPC 1650 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 03/04/2025 was unsatisfactory: HPC >100 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on April 9, 2025, was unsatisfactory: HPC 1650 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample collected on 03/04/2025 was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 03/04/2025 was unsatisfactory: HPC >100 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine was 2.99ppm and greater than the free chlorine 1.08ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Temperature of the whirlpool was 41C
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand accumulation was noted in the basin beside the drain cover.Vacuum the basin and maintain in a clean and sanitary condition
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on December 30, 2024, was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on December 30, 2024, was unsatisfactory: HPC 57000 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand accumulation was noted in the basin beside the drain cover.Vacuum the basin and maintain in a clean and sanitary condition
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand accumulation was noted in the basin beside the drain cover.Vacuum the basin and maintain in a clean and sanitary condition
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on 06-12-2024 was unsatisfactory: Pseudomonas aeruginosa isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 06/12/2024 was unsatisfactory: HPC >100 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand accumulation was noted in the basin beside the drain cover.Vacuum the basin and maintain in a clean and sanitary condition
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand accumulation was noted in the basin beside the drain cover.Vacuum the basin and maintain in a clean and sanitary condition
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on October 31, 2024, was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand accumulation was noted in the basin beside the drain cover.Vacuum the basin and maintain in a clean and sanitary condition
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand accumulation was noted in the basin beside the drain cover.Vacuum the basin and maintain in a clean and sanitary condition
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- TC is present in the Aug 28, 2024 bacteriological water sample.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand accumulation was noted in the basin beside the drain cover.Vacuum the basin and maintain in a clean and sanitary condition
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand accumulation was noted in the basin beside the drain cover.Vacuum the basin and maintain in a clean and sanitary condition
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on 27 June 2024 was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand accumulation was noted in the basin beside the drain cover.Vacuum the basin and maintain in a clean and sanitary condition
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand accumulation was noted in the basin beside the drain cover.Vacuum the basin and maintain in a clean and sanitary condition
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- the bacteriological water sample collected on 6 June was unsatisfactory. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand accumulation was noted in the basin beside the drain cover.Vacuum the basin and maintain in a clean and sanitary condition
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand accumulation was noted in the basin beside the drain cover.Vacuum the basin and maintain in a clean and sanitary condition
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- According to Lab report (preliminary result) received on 24 May, the microbiological sample collected 23 May 2024 was unsatisfactory. Total coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand accumulation was noted in the basin beside the drain cover.Vacuum the basin and maintain in a clean and sanitary condition
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Sand accumulation was noted in the basin beside the drain cover.Vacuum the basin and maintain in a clean and sanitary condition
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Combined chlorine 3.95ppmIdeally combine chlorine should be maintained below 1ppm.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The wall clock was not operational during inspection onsite.Replace the batteries and ensure the clock is operational all the time.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Monitoring Inspection
1 infraction
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The wall clock was not operational during inspection onsite.Replace the batteries and ensure the clock is operational all the time.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Risk Management Inspection
1 infraction
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The wall clock was not operational during inspection onsite.Replace the batteries and ensure the clock is operational all the time.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on 16-November-2023 was unsatisfactory: Pseudomonas aeruginosa isolated, Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 16-November-2023 was unsatisfactory: HPC >57000 CFU/ML. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The wall clock was not operational during inspection onsite.Replace the batteries and ensure the clock is operational all the time.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
1 infraction
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- The wall clock was not operational during inspection onsite.Replace the batteries and ensure the clock is operational all the time.
- 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The skimmer does not seem to be skimming the water adequately. The same floaties/debris were at the top of the water in the whirlpool for the entire 1-hour inspection with a turnover period of 14.26minutes. Work with your pool operator on troubleshooting and take corrective actions. The pH reading on the automated controller of 7.1 was not consistent with the manual reading of 7.4. Troubleshoot and take corrective actions.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on Aug 31, 2023 was unsatisfactory: Pseudomonas aeruginosa isolated, Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 31 August, 2023 was unsatisfactory: HPC >57000 CFU/ML. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The skimmer does not seem to be skimming the water adequately. The same floaties/debris were at the top of the water in the whirlpool for the entire 1-hour inspection with a turnover period of 14.26minutes. Work with your pool operator on troubleshooting and take corrective actions. The pH reading on the automated controller of 7.1 was not consistent with the manual reading of 7.4. Troubleshoot and take corrective actions.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on 13 July 2023 was unsatisfactory: Pseudomonas aeruginosa isolated, Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 13 July 2023 was unsatisfactory: HPC 2860 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The skimmer does not seem to be skimming the water adequately. The same floaties/debris were at the top of the water in the whirlpool for the entire 1-hour inspection with a turnover period of 14.26minutes. Work with your pool operator on troubleshooting and take corrective actions. The pH reading on the automated controller of 7.1 was not consistent with the manual reading of 7.4. Troubleshoot and take corrective actions.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?