Sandman Hotel - Swimming Pool
8001 11 Street SE Calgary AB T2H 0B8 · Aquatic Facility
18 inspections
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on May 12 did not have date and time of collection on the requisition, so the Lab rejected the samples. -resample
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. Manual water chemistry test measured pH 7.09 and the automated controller read 7.5.COMPLETE THE FOLLOWING:1. Please re-calibrate the automated controller to ensure readings are accurate.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. Manual water chemistry test measured pH 7.09 and the automated controller read 7.5.COMPLETE THE FOLLOWING:1. Please re-calibrate the automated controller to ensure readings are accurate.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
4 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. The flow metre was not operational.COMPLETE THE FOLLOWING:1. Replace the flow metre.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- 1. The drain covers for the swimming pool were expired. COMPLETE THE FOLLOWING:1. Replace with appropriate drain covers and ensure they are installed according to the manufacturer's instructions.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- 1. The following test reagents were passed their best before dates:- DPD reagent #1: 2025- DPD reagent #2: 01/2025- DPD reagent #3: 12/2025- pH indicator: 10/2025- Total alkalinity indicator: 11/2025- Thiosulfate N10: 12/20252. Several best before dates on the test reagent bottles had worn off and were not easily visible. 3. The test chamber for the chlorine side was discoloured. COMPLETE THE FOLLOWING:1. Please replace the test reagents, and do not use the reagents beyond the best before dates. 2. Ensure the test reagents are always labeled with their best before dates. 3. Replace the test chamber.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- 1. The anti-entrapment plans were not current as the drain covers expired. COMPLETE THE FOLLOWING:1. Complete new anti-entrapment plans, and submit to Environmental Public Health for review along with the supporting documents (i.e., sump dimensions, drain cover certificates of compliance, plumbing schematics, etc.).
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on Sept 9, 2025 had Total Coliform Present.-treat and resampleID: 25ES-252E00720
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on Jul 8, 2025 had 320 CFU/100mL.ID: 25ES-189E00687-Treat the pool and resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on Jul 2, 2025 had 140 CFU/100mL.ID: 25ES-183E00248-treat the pool and resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on June 10, 2025 resulted in 1080 CFU/mL-resample
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on Feb 18, 2025 was not processed since the Access number was not provided nor was the identification label on the bottle.-ID: 25ES-049E00103; Req ID #: 2588685
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The sample submitted on September 3, 2024 was not procssed as there was no ID number on the bottle.Resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The sample collected on July 9, 2024 had total coliforms present.Treat the pool and send in a resample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The sample submitted on March 17, 2024 was not processed as there was no ID number on the bottle. Resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The sample submitted on January 23, 2024 was not processed as there was no ID number on the bottle.Submit a resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The sample collected on December 5, 2023 had an HPC count of 750 CFU/ml.Treat and resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
0 infractions
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The sample collected on October 31, 2023 was not processed as there was no ID number on the bottle submitted. Send in a resample and label the bottle properly.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- 1. There is sand at the bottom of the pool in some of the corners and along the edge.2. There are unclean skimmer baskets that had a build up of hair and debris.1. and 2. Please ensure these areas are cleaned regularly to prevent the build up of debris.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The sample collected on July 18, 2023 had an HPC count of 300 CFU/mL. The access number and sample type was also not provided on the sample. Treat the pool and send in a resample.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- 1. There is sand at the bottom of the pool in some of the corners and along the edge.2. There are unclean skimmer baskets that had a build up of hair and debris.1. and 2. Please ensure these areas are cleaned regularly to prevent the build up of debris.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?