Sandman Hotel - Swimming Pool
888 7 Avenue SW Calgary AB T2P 3J3 · Aquatic Facility
6 inspections
- Monitoring Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine (CC) was measured to be 1.47ppm. Please keep the CC as low was possible (at least under 1.0ppm) to reduce bather skin and mucous membrane irritation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- The anti-entrapment plan has not been updated with the new cover details. A copy of the AHS anti-entrapment plan template will be emailed along with this report. Please complete the plan and submit to the undersigned PHI for review.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample (26ES-139E00008) collected on May 19th, 2026, came back unsatisfactory as the HPC level was elevated to >57,000CFU/mL. The maximum acceptable concentration is 100CFU/mL. Please resample the swimming pool as soon as possible.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- The Wier in the skimmers were placed upside down which was preventing proper skimming of water.The weir was placed in proper alignment by the operator.-Please ensure that the weir in the skimmers is placed in proper alignment to allow skimming of water.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected May 21, 2024 - HPC 110 CFU/mL-Resample
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?