Skip to content
Loading map…

Shannon Wall Centre - Outdoor Whirlpool

1520 Atlas Lane, Vancouver BC V6P 0E1 · Hot Tub

Inspection summary

Shannon Wall Centre - Outdoor Whirlpool has been inspected 19 times by Vancouver Coastal Health since July 15, 2016. The most recent inspection, on April 15, 2026, recorded 2 infractions.

None of the 19 inspections on record were free of infractions. In the past 12 months there were 3 inspections with 9 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality, Chemicals and toxic substances and Food temperature control.

Recent inspections have recorded more infractions than earlier ones, so it is worth reading the latest reports closely.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 56 times across 19 separate inspections, most recently on April 15, 2026. For example: The operator maintains the pool in good repair.

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 2 times across 2 separate inspections, most recently on April 10, 2026. For example: Chemicals are stored in a safe manner and location

  • Food temperature controlHigher risk

    Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.

    Recorded 2 times across 2 separate inspections, most recently on May 16, 2025. For example: The pool water temperature is properly maintained

  • Equipment and utensilsLower risk

    Pumps, filters, chemical feeders and safety equipment such as lifebuoys, reaching poles and first-aid kits must be present and working. Missing safety equipment can matter a great deal in an emergency.

    Recorded 16 times across 12 separate inspections, most recently on April 15, 2026. For example: Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications

  • Other findingsLower risk

    Findings that do not fit the categories above, such as follow-ups that confirm an earlier violation was corrected, or requirements specific to this type of facility.

    Recorded 5 times across 5 separate inspections, most recently on May 15, 2023. For example: The hot tub enclosure has a clock and instructions for safe use of the hot tub, in clear view

About this data

These results come from Vancouver Coastal Health, which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

19 inspections

  1. Routine Follow-up

    2 infractions

    • The operator maintains the pool in good repair.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
  2. Routine Follow-up

    3 infractions

    • Chemicals are stored in a safe manner and location
    • The operator maintains the pool in good repair.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
  3. Routine

    4 infractions

    • Chemicals are stored in a safe manner and location
      • Chemicals are stored directly on the floor.
    • The operator maintains the pool in good repair.
      • Handrails at steps, ladders and diving boards are not secure.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
    • Daily pool records are adequately maintained and available on site
  4. Routine

    4 infractions

    • The pool alkalinity is properly maintained
    • The pool cyanuric acid stabilizer level is properly maintained
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
    • Daily pool records are adequately maintained and available on site
  5. Routine

    8 infractions

    • The pool water temperature is properly maintained
    • The pool disinfectant is properly maintained
    • The pool combined chlorine level is properly maintained
      • The pool combined chlorine level is greater than or equal to 1.0 ppm
    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool alkalinity is properly maintained
      • Total Alkalinity is too low and is not at a level to maintain chemically balanced pool water.
    • Adequate safety equipment is provided
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • A ground fault interrupter is not functional on the underwater light circuits
    • Daily pool records are adequately maintained and available on site
      • Results of water testing are inadequately recorded.
  6. Routine

    6 infractions

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool alkalinity is properly maintained
      • Total Alkalinity is too low and is not at a level to maintain chemically balanced pool water.
    • Adequate safety equipment is provided
      • Pool is not equipped with a throwing ring and/or the rope for the ring is not at least ½ the width of the pool plus 3 metres (N/A for pools < 10m²)
    • The operator maintains the pool in good repair.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
    • Daily pool records are adequately maintained and available on site
  7. Routine

    5 infractions

    • The pool disinfectant is properly maintained
    • Adequate safety equipment is provided
    • The pool is clean, clear of obstructions, and adequately supplied
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
    • Daily pool records are adequately maintained and available on site
      • Results of water testing are inadequately recorded.
  8. Routine Follow-up

    6 infractions

    • The pool disinfectant is properly maintained
      • Free available chlorine is in excess of 10 ppm.
    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool is clean, clear of obstructions, and adequately supplied
      • The pool is not kept clean and clear of obstructions.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • Flow meter is not functioning correctly
    • An operator of a pool has prepared, maintains, and follows a written pool safety plan to ensure the health and safety of pool patrons
      • Pool safety plan is not adequately developed.
    • Daily pool records are adequately maintained and available on site
      • Results of water testing are inadequately recorded.
  9. Routine

    13 infractions

    • The Permit to Operate a pool is valid and is posted in a prominent location.
      • Permit to Operate is not posted in a prominent location.
    • The pool water temperature is properly maintained
    • The pool disinfectant is properly maintained
      • Free available chlorine is less than 0.5 ppm at temperature of 30°C or below.
    • The pool combined chlorine level is properly maintained
      • The pool combined chlorine level is greater than or equal to 1.0 ppm
    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool cyanuric acid stabilizer level is properly maintained
      • The cyanuric acid stabilizer level is greater than 80 ppm
    • The hot tub enclosure has a clock and instructions for safe use of the hot tub, in clear view
    • Adequate safety equipment is provided
    • The pool is clean, clear of obstructions, and adequately supplied
      • The pool is not kept clean and clear of obstructions.
      • Soap and/or single-use hand towels are not available in the dispensers.
      • Soap dispensers, air dryers, or single-use hand towels are not supplied near the hand basins.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • The pool chemical test kit is absent/not in good condition and/or cannot produce accurate readings for required chemical parameters.
      • Skimmer does not adequately draw surface water from the pool.
    • An operator of a pool has prepared, maintains, and follows a written pool safety plan to ensure the health and safety of pool patrons
      • Pool safety plan is not adequately developed.
    • Drinking water is reasonably accessible by pool patrons
    • Daily pool records are adequately maintained and available on site
      • Results of water testing are inadequately recorded.
  10. Routine

    7 infractions

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • The hot tub enclosure has a clock and instructions for safe use of the hot tub, in clear view
      • Clock prominently displaying the time is not present or in clear view
      • Instructions for the safe use of the hot tub is not present or in clear view
    • Pool rules are posted prominently within the pool enclosure
      • Safety rules sign missing, incomplete, or not clearly visible to the public
      • “No lifeguard on duty” sign missing, incomplete, or not clearly visible to the public at the entrance
    • The pool is clean, clear of obstructions, and adequately supplied
      • The pool is not kept clean and clear of obstructions.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • The automatic chlorinator cannot produce a reliable chemical residual.
      • The pool pumps are not working or are in disrepair.
    • Drinking water is reasonably accessible by pool patrons
  11. Routine Follow-up

    3 infractions

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • The hot tub enclosure has a clock and instructions for safe use of the hot tub, in clear view
      • Clock prominently displaying the time is not present or in clear view
      • Instructions for the safe use of the hot tub is not present or in clear view
  12. Routine

    4 infractions

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • The pool cyanuric acid stabilizer level is properly maintained
      • The cyanuric acid stabilizer level is greater than 80 ppm
    • The hot tub enclosure has a clock and instructions for safe use of the hot tub, in clear view
      • Clock prominently displaying the time is not present or in clear view
  13. Routine

    1 infraction

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
  14. Routine

    3 infractions

    • The pool pH level is properly maintained
    • The hot tub enclosure has a clock and instructions for safe use of the hot tub, in clear view
      • Clock prominently displaying the time is not present or in clear view
    • Drinking water is reasonably accessible by pool patrons
  15. Routine

    2 infractions

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • Flow meter is not functioning correctly
  16. Routine

    3 infractions

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • Drinking water is reasonably accessible by pool patrons
  17. Routine

    3 infractions

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • Flow meter is not functioning correctly
    • An operator of a pool has prepared, maintains, and follows a written pool safety plan to ensure the health and safety of pool patrons
  18. Routine Follow-up

    1 infraction

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
  19. Routine

    3 infractions

    • The pool alkalinity is properly maintained
    • Pool water velocity and recirculation rate is properly maintained
    • The pool is regularly maintained and kept in good repair by an appropriately trained person