Sheraton Suites - Whirlpool has been inspected 8 times by Alberta Health Services (Environmental Public Health) since January 25, 2024. The most recent inspection, on November 14, 2025, recorded 1 infraction.
2 of 8 inspections on record found no infractions at all. In the past 12 months there were 2 inspections with 2 infractions recorded. The higher-risk findings here relate to: Food temperature control, Chemicals and toxic substances and Pool and spa water quality.
The number of infractions per inspection has stayed roughly the same over time.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Food temperature controlHigher risk
Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.
Recorded 3 times across 3 separate inspections, most recently on July 29, 2024. For example:
Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
Chemicals and toxic substancesHigher risk
Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.
Recorded 2 times across 2 separate inspections, most recently on November 14, 2025. For example:
Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 2 times across 2 separate inspections, most recently on July 18, 2025. For example:
Is the bacteriological quality of the water in this pool satisfactory (Critical)?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
8 inspections
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine was measured to be 1.39ppm. Combined chlorines are to be kept as low as possible. Please add fresh water to dilute the combined chlorine in the pool.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity of the hot tub water has been measured at 36 mg/L, which is below the recommended range of 60–180 mg/L. Please add sodium bicarbonate to the hot tub, to bring the alkalinity level within the ideal range.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on July 15, 2025, had Pseudomonas Isolated in the sample.**Please begin treatment for the whirlpool immediately. **Submit a re-sample after the treatment is completed and water chemistry is re-balanced
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Temperature of the whirlpool measured 40.6 C.Lower temperature of whirlpool so it is at 40C or below.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken July 23, 2024 - HPC @ 630 CFU/mL.-Resample
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Temperature of the whirlpool measured 40.6 C.Lower temperature of whirlpool so it is at 40C or below.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Temperature of the whirlpool measured 40.6 C.Lower temperature of whirlpool so it is at 40C or below.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?