Shu Beauty
8 - 1420 9 Avenue SE Calgary AB T2G 0T5 · Personal Services
Inspection summary
Shu Beauty has been inspected 4 times by Alberta Health Services (Environmental Public Health) since June 16, 2025. The most recent inspection, on October 13, 2026, found no infractions.
2 of 4 inspections on record found no infractions at all. In the past 12 months there was 1 inspection with 0 infractions recorded. All recorded findings relate to upkeep, equipment or paperwork rather than direct infection-control risks to clients.
The last 2 inspections in a row found no infractions. Recent inspections have recorded fewer infractions than earlier ones, so the record is improving.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for clients. In personal service settings like salons, spas and tattoo studios, higher-risk findings are the ones that could spread infection from one client to the next, through broken skin, blood or instruments that were not properly cleaned and sterilized.
Permits, records and postingLower risk
Operating permits, client records, sterilization logs and required signage. Client records matter because they let health officials contact people if an infection is linked to the business.
Recorded 3 times across 2 separate inspections, most recently on June 17, 2025. For example:
Are written procedures reviewed and revised when required, and do they meet the requirements set out in the standards?
Equipment and utensilsLower risk
Instruments, chairs, tables and footbaths must be made of materials that can be cleaned, kept in good repair and stored so they stay clean. Single-use items such as nail files, buffers, razors and needles must be thrown away after each client.
Recorded 2 times across 2 separate inspections, most recently on June 17, 2025. For example:
Is reusable equipment disinfected properly?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
4 inspections
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Risk Management Inspection
2 infractions
- 05. Are written procedures reviewed and revised when required, and do they meet the requirements set out in the standards?
- Written procedures are not available for the following: - Cleansing of the skin (CORRECTED)- Application of antiseptic - Post-service care for energy-emitting devices (Laser) - Decontamination of sink when used for both handwashing and equipment reprocessing (CORRECTED)Written procedures must be developed and maintained for staff awareness. An AHS written procedure template was provided to the operator.
- 20. Is reusable equipment disinfected properly?
- No test strips available for the high-level disinfectant. The operator is reusing the high-level disinfectant for more than a day. Test strips must be used to test the concentration of the high-level disinfectant if planning to reuse the solution up to 14 days as indicated on the manufacturer's instructions. Please obtain appropriate test strips for the high-level disinfectant.
- 05. Are written procedures reviewed and revised when required, and do they meet the requirements set out in the standards?
- Initial Inspection
3 infractions
- 05. Are written procedures reviewed and revised when required, and do they meet the requirements set out in the standards?
- Written procedures are not available for the following: - Cleansing of the skin - Application of antiseptic - Post-service care for energy-emitting devices (Laser) - Decontamination of sink when used for both handwashing and equipment reprocessing Written procedures must be developed and maintained for staff awareness. An AHS written procedure template was provided to the operator.
- 10. Is cleansing and antisepsis of skin and mucous membrane performed in accordance to written procedures and are suitable products being used?
- No antiseptic available during the inspection. Procedures that puncture the skin require a cleansing step followed by the use of an antiseptic. Lancets are used for the sugaring service. The operator stated they have ordered isopropyl alcohol 70%.
- 20. Is reusable equipment disinfected properly?
- No test strips available for the high-level disinfectant. The operator is reusing the high-level disinfectant for more than a day. Test strips must be used to test the concentration of the high-level disinfectant if planning to reuse the solution up to 14 days as indicated on the manufacturer's instructions. Please obtain appropriate test strips for the high-level disinfectant.
- 05. Are written procedures reviewed and revised when required, and do they meet the requirements set out in the standards?