Skyridge at Harvie Heights - Whirlpool
750 Harvie Heights Road Harvie Heights AB T1W 2W2 · Aquatic Facility
Inspection summary
Skyridge at Harvie Heights - Whirlpool has been inspected 4 times by Alberta Health Services (Environmental Public Health) since February 4, 2025. The most recent inspection, on January 29, 2026, recorded 1 infraction.
1 of 4 inspections on record found no infractions at all. In the past 12 months there was 1 inspection with 1 infraction recorded. The higher-risk findings here relate to: Pool and spa water quality.
Recent inspections have recorded more infractions than earlier ones, so it is worth reading the latest reports closely.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 4 times across 3 separate inspections, most recently on January 29, 2026. For example:
Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
4 inspections
- Demand Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. Flow rate exceeded max flow rate of 61GPM, flow meter was reading 70 GPM. Filtration rate is 14.3 GPM/sqft. - Please adjust flow rate so it does not exceed the max flow rate for the filter.2. The pH measured (7.44) is higher than the reading, 7.2 (set 7.3).-Ensure the automated and monitoring equipment are well calibrated
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample from Wednesday July 2nd, 2025, had Total Coliforms present. - Operators were informed to treat and re-sample.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. Flow rate exceeded max flow rate of 61GPM, flow meter was reading 70 GPM. Filtration rate is 14.3 GPM/sqft. - Please adjust flow rate so it does not exceed the max flow rate for the filter.2. The pH measured (7.44) is higher than the reading, 7.2 (set 7.3).-Ensure the automated and monitoring equipment are well calibrated
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. Flow rate exceeded max flow rate of 61GPM, flow meter was reading 70 GPM. Filtration rate is 14.3 GPM/sqft. - Please adjust flow rate so it does not exceed the max flow rate for the filter.2. The pH measured (7.44) is higher than the reading, 7.2 (set 7.3).-Ensure the automated and monitoring equipment are well calibrated
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Initial Inspection
0 infractions