Skip to content
Loading map…

Southview Grand Condos - Hot Tub

3021 13 Avenue SE Medicine Hat AB T1B 4E2 · Aquatic Facility

18 inspections

  1. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC: >57,000 CFU/ml
  2. Risk Management Inspection

    0 infractions

  3. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Total Alkalinity (TA) was measured at 58 ppm, which is slightly below the required minimum of 60 ppm.
  4. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Total Alkalinity (TA) was measured at 58 ppm, which is slightly below the required minimum of 60 ppm.
  5. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The following chemical parameters are below the required levels:Free Available Chlorine (FAC): 1.23 ppm (required minimum: 2.0 ppm)pH: 6.5 (required minimum: 6.8)
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Total Alkalinity (TA) was measured at 0 ppm, which is below the required minimum of 60 ppm.
  6. Risk Management Inspection

    0 infractions

  7. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Lab testing indicates that Pseudomonas is present in the hot tub
  8. Risk Management Inspection

    0 infractions

  9. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The hot tub water sample collected on September 09 indicate Pseudomonas aeruginosa has been ISOLATED.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The HPC is exceedingly high (>57 000 CFU/mL).[This hot tub sample was collected on September 09, 2024.]
  10. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected March 13 showed an HPC level of 180 CFU/mL. ProvLab results for the hot tub water sample collected on March 13 indicate a slightly elevated HPC (130 CFU/mL).
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • 1. Bacteriological water samples are being collected from the spigot at the automated system. 2. Aseptic sampling techniques are not being employed: (i) Handwashing is not performed prior to sampling. (ii) The bottle cap is not carefully and properly removed/"pinched" to avoid contaminating the sterile insides of both the cap and the bottle. (iii) The cap is placed on the ground or cupped in hand. (iv) The sample bottle is held stationary under the water with the sampler's hand over, or in close proximity to, the bottle's mouth.
  11. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected March 13 showed an HPC level of 180 CFU/mL. ProvLab results for the hot tub water sample collected on March 13 indicate a slightly elevated HPC (130 CFU/mL).
  12. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • ProvLab results for the hot tub water sample collected on March 13 indicate Pseudomonas aeruginosa has been ISOLATED.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • ProvLab results for the hot tub water sample collected on March 13 indicate a slightly elevated HPC (130 CFU/mL).
  13. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Sample result indicates that Pseudomonas aeruginosa was isolated.
    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Sample result indicates that Pseudomonas aeruginosa was isolated.
  14. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Sample result indicates that Pseudomonas aeruginosa was isolated.
  15. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • A sample of the hot tub water shows the presence of total coliforms.
  16. Risk Management Inspection

    1 infraction

    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The hot tub basin has extensive surface/hair line cracks in many areas. The hot tub basin light is not working.
  17. Risk Management Inspection

    0 infractions

  18. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Pseudomonas isolated in water sample.Hot tub will be closed, and shock chlorinated, drained and new sample submitted prior to opening.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The hot tub basin has extensive surface/hair line cracks in many areas. The hot tub basin light is not working.