Stettler Recreation Center - Main Swimming Pool

6202 44 Avenue Stettler AB T0C 2L1 · Aquatic Facility

17 inspections

  1. Monitoring Inspection

    0 infractions

  2. Risk Management Inspection

    0 infractions

  3. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC 150
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • CAC should be kept at 0.5 ppm or lower.
  4. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • CAC should be kept at 0.5 ppm or lower.
  5. Risk Management Inspection

    0 infractions

  6. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Report of the water sample collected on September 24, 2025 unsatisfactory.HPC = 170 CFU/mLReport discussed with Ethan.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC 650
  7. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC 650
  8. Risk Management Inspection

    0 infractions

  9. Risk Management Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Sample results for sample taken 16Apr2025 indicated total coliform bacteria present.Wednesday is high bather load day with bathers in the basin at the time of the sample. Suspect bather proximity to account for the result. Pool chemistry prior to, at time of and following sampling event were within acceptable ranges.*** Please resample at you next earliest availability. ***
  10. Monitoring Inspection

    0 infractions

  11. Risk Management Inspection

    0 infractions

  12. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample taken February 26, 2025 came back with HPC of 300.Manager advised they will increase the free chlorine for a couple days and is unsure why there would be a high HPC as there were no crazy loads on the pool.
  13. Risk Management Inspection

    0 infractions

  14. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TA 66 ppm pH 7.17 ppm TAC 3.04 ppm FAC 2.46 ppmCAC 0.58 ppm - HIGH
  15. Monitoring Inspection

    0 infractions

  16. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The water is to the top of the skimmers instead of half-way up to facilitate skimming of the surface water. Advised this is because a backwash is going to occur in about an hour and then they will ensure the water is halfway up the skimmer.
  17. Risk Management Inspection

    0 infractions