Stonegate Recreation Centre - Whirlpool

9318 47 Avenue Grande Prairie AB T8W 2G6 · Aquatic Facility

8 inspections

  1. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Heterotrophic plate count - 3750 CFU/mlThe owner / operator of this facility is requested to conduct the following, namely:1. Shock / Superchlorinate the whirlpool.2. Re-balance the whirlpool.3. Submit a re-sample to the regional health authority.Ensure the heterotrophic plate count is kept below 100 CFU/ML at all times.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • At time of inspection:1. The anti-entrapment plan submitted indicates that the main drain covers have a 5-year expiry. Installation of the main drain covers (according to the anti-entrapment plan) were installed on August 24, 2018.The owner / operator of this facility is requested to conduct the following, namely:1. Replace all main drain covers. Ensure they are installed as per the manufacturer's requirements.
  2. Risk Management Inspection

    1 infraction

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • At time of inspection:1. The anti-entrapment plan submitted indicates that the main drain covers have a 5-year expiry. Installation of the main drain covers (according to the anti-entrapment plan) were installed on August 24, 2018.The owner / operator of this facility is requested to conduct the following, namely:1. Replace all main drain covers. Ensure they are installed as per the manufacturer's requirements.
  3. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The Provincial laboratory submitted the following whirlpool water sample results for June 11, 2025: TOTAL COLIFORMS - PRESENTPSEUDOMONAS AERUGINOSA - ISOLATED.Please close this whirlpool and conduct the following, namely:- drain the whirlpool- scrub and disinfect the surfaces of the whirlpool- re-fill the whirlpool- re-balance the whirlpool- keep the whirlpool closed until a satisfactory whirlpool water result is indicated by the Provincial Lab.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Heterotrophic plate count - 250 CFU/mlEnsure the heterotrophic plate count is kept below 100 CFU/ML at all times.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • At time of inspection:1. The anti-entrapment plan submitted indicates that the main drain covers have a 5-year expiry. Installation of the main drain covers (according to the anti-entrapment plan) were installed on August 24, 2018.The owner / operator of this facility is requested to conduct the following, namely:1. Replace all main drain covers. Ensure they are installed as per the manufacturer's requirements.
  4. Risk Management Inspection

    1 infraction

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • At time of inspection:1. The anti-entrapment plan submitted indicates that the main drain covers have a 5-year expiry. Installation of the main drain covers (according to the anti-entrapment plan) were installed on August 24, 2018.The owner / operator of this facility is requested to conduct the following, namely:1. Replace all main drain covers. Ensure they are installed as per the manufacturer's requirements.
  5. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • CHEMICAL PARAMETER RESULTSpH @ 7.7 - TOO HIGHFAC @ 6.0 - TOO HIGHTAC @ 6.8CAC @ 0.8ALKALINITY @ 87 ORP (Meter) @ 675 mVThe owner / operator of this facility is requested to conduct the following, namely:1. Decrease both free chlorine to less than 5.0 PPM and pH to between 6.8-7.6.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • At time of inspection:1. The anti-entrapment plan submitted indicates that the main drain covers have a 5-year expiry. Installation of the main drain covers (according to the anti-entrapment plan) were installed on August 24, 2018.The owner / operator of this facility is requested to conduct the following, namely:1. Replace all main drain covers. Ensure they are installed as per the manufacturer's requirements.
  6. Risk Management Inspection

    0 infractions

  7. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Total Coliforms - PresentPseudomonas Aeruginosa isolated.Ensure hot tub is closed for public use. Clean, shock chlorinate, balance the pool water chemistry and then submit another water sample. Hot tub is to remain closed until satisfactory pool water sample results are obtained.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC noted at 1690 CFU/mL
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plans for the whirlpool were unavailable during the inspection. Please ensure anti-entrapment plans are available for review. *****PLEASE PROVIDE AN UPDATE TO THE REGIONAL HEALTH AUTHORITY ON THIS COMPLIANCE ITEM.
  8. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC noted at 840 CFU/mLPlease ensure you raise FAC to 10ppm while keeping pH at or near 7.2. Run water through circulation system and adjust water chemistry to operating standards then re-submit new water sample for testing.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Anti-entrapment plans for the whirlpool were unavailable during the inspection. Please ensure anti-entrapment plans are available for review.