Suncor Community Leisure Center - Adult Whirlpool

1 CA Knight Way Fort McMurray AB T9H 5C5 · Aquatic Facility

12 inspections

  1. Risk Management Inspection

    0 infractions

  2. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1-Flow rate 440gpm- minimum required flowrate is 520gpm to achieve turnover of 20min.2-Operational Turnover 25min.Adjust the flow rate
  3. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • 1-Flow rate 500gpm- minimum required flowrate is 550gpm to acheive turnover of 20min.2-Operational Turnover 22min.Adjust the flow rate and Ensure turn over remain below 20min to have adequate circulation and disinfection of pool water for water safety.3-There were discrepancies noted between automated controller reading and manual test results for water chemistry. pH 6.84 Manual and 7.2 automated controller reading. Ensure the test results are consistent.
  4. Risk Management Inspection

    0 infractions

  5. Monitoring Inspection

    0 infractions

  6. Risk Management Inspection

    0 infractions

  7. Monitoring Inspection

    0 infractions

  8. Monitoring Inspection

    0 infractions

  9. Monitoring Inspection

    0 infractions

  10. Monitoring Inspection

    0 infractions

  11. Risk Management Inspection

    0 infractions

  12. Monitoring Inspection

    1 infraction

    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Damage on siding of the whirlpool. Ensure pool is maintained in good repair.