Skip to content
Loading map…

Sunny Chinooks Camping Association - Hot Tub

5048 Township Road 342 Mountain View County AB T0M 0K0 · Aquatic Facility

Inspection summary

Sunny Chinooks Camping Association - Hot Tub has been inspected once by Alberta Health Services (Environmental Public Health), on August 6, 2026. The most recent inspection, on August 6, 2026, recorded 3 infractions.

In the past 12 months there was 1 inspection with 3 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 2 times on August 6, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded once on August 6, 2026. For example: Is the chemical quality of the water in this pool satisfactory (Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

1 inspection

  1. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • 1. Weekly biological samples to be submitted by operator during period of operation.Access Numb: 90172105 Aug - bact sample taken by PHI
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • 1. Hot tub was operating on bromine. Operator to switch over to chlorine disinfection immediately and begin to test for: - Free Chlorine (> 2.0 ppm) - Combined Chlorine - pH (6.8-7.6) - Alkalinity (60-180)
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Volume: 575 usgFlow Rate: unknown - need to install a flow meterTurnover: unknownMinimum Turnover Time: 15 minutesMinimum Flow Rate to Achieve Minimum Turnover Time: 39 gpm1. An automated control system is required for the pool disinfection system.

Nearby inspected facilities

Own this business? Add a badge to your website