Tall Timber Leisure Park - Hot Tub
606 Main Avenue E Sundre AB T0M 1X0 · Aquatic Facility
8 inspections
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- 1. Routine water sample result: Pseudomonas PresentClose the pool from public use immediately. Drain and thoroughly clean and sanitize the pool basin and all accessible surfaces. Shock chlorinate the pool. After shock chlorinating, backwash the filter. Re-balance the water chemistry to bring the free chlorine level to at least 2.0ppm. The pool can then be re-opened to the public.Resample on your regular sampling day
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Risk Management Inspection
2 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- 1. The pH was measured at 8.4. The auto controller showed pH at 7.4. Auto controller sensors had not been changed recently. Operator voluntarily closed the whirlpool until the pH could be brough back into range and the conflict with the auto controller solved.
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- Whirlpool Volume: 1823 GalFlow Rate: 75 GPMTurnover: 24 mins (must be 20 minutes)Minimum flow rate to meet 20 minutes turnover requirement is: 92 GPM (349 L/min)
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- HPC 280
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- Whirlpool Volume: 6902 L = 1823 GalFlow Rate: 225 L/min = 59.4 GPMTurnover: 31 mins (must be 20 minutes)Filter: Pentair Triton 2 TR140CMax filtration rate: 141 GPMMinimum flow rate to meet 20 minutes turnover requirement is: 92 GPM (349 L/min)
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
- Whirlpool Volume: 6902 L = 1823 GalFlow Rate: 225 L/min = 59.4 GPMTurnover: 31 mins (must be 20 minutes)Filter: Pentair Triton 2 TR140CMax filtration rate: 141 GPMMinimum flow rate to meet 20 minutes turnover requirement is: 92 GPM (349 L/min)
- 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?