Skip to content
Loading map…

Tania Medi Spa

342 14 Street NW Calgary AB T2M 1Z7 · Personal Services

Inspection summary

Tania Medi Spa has been inspected 7 times by Alberta Health Services (Environmental Public Health) since April 5, 2024. The most recent inspection, on October 6, 2026, recorded 6 infractions.

1 of 7 inspections on record found no infractions at all. In the past 12 months there were 5 inspections with 19 infractions recorded. The higher-risk findings here relate to: Hand hygiene and infection control.

Recent inspections have recorded more infractions than earlier ones, so it is worth reading the latest reports closely.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for clients. In personal service settings like salons, spas and tattoo studios, higher-risk findings are the ones that could spread infection from one client to the next, through broken skin, blood or instruments that were not properly cleaned and sterilized.

  • Hand hygiene and infection controlHigher risk

    Infection control is the core of a personal service inspection. Inspectors check that operators clean their hands and change gloves between clients, that a stocked hand sink is available, and that anything that breaks the skin is handled so blood-borne infections such as hepatitis B, hepatitis C and HIV cannot pass from one client to the next.

    Recorded once on April 5, 2024. For example: Is hand hygiene performed by the personal services worker when required, in a proper manner and are provisions available to perform hand hygiene?

  • Equipment and utensilsLower risk

    Instruments, chairs, tables and footbaths must be made of materials that can be cleaned, kept in good repair and stored so they stay clean. Single-use items such as nail files, buffers, razors and needles must be thrown away after each client.

    Recorded 10 times across 4 separate inspections, most recently on October 6, 2026. For example: Is reusable equipment disinfected properly?

  • Permits, records and postingLower risk

    Operating permits, client records, sterilization logs and required signage. Client records matter because they let health officials contact people if an infection is linked to the business.

    Recorded 6 times across 5 separate inspections, most recently on October 6, 2026. For example: Are facility-specific written procedures established to adequately describe safe and sanitary practices?

  • Food safety training and certificationLower risk

    Some jurisdictions require operators to complete infection-prevention training, or to hold specific qualifications for higher-risk services such as tattooing, piercing or electrolysis. These findings mean the training record was missing at the time. They do not by themselves mean a client was put at risk.

    Recorded once on October 6, 2026. For example: Do operators and personal services workers comply with the Personal Services Regulation and Standards and do they have the skills and knowledge to perform their duties in a safe and sanitary manner?

  • Other findingsLower risk

    Findings that do not fit the categories above, such as follow-ups that confirm an earlier violation was corrected, or requirements specific to this type of facility.

    Recorded 6 times across 4 separate inspections, most recently on October 6, 2026. For example: Are general nuisance conditions, other than those noted in other violations, being prevented at this personal services facility (Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

7 inspections

  1. Risk Management Inspection

    6 infractions

    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • Written facility procedures for the following were not onsite:1. Skin cleansing/ antiseptic use2. Decontamination procedures for cleaning and disinfecting dual purpose sink for handwashing and reprocessing equipment. 3. Procedures for accidental injury/cuts
    • 06. Do operators and personal services workers comply with the Personal Services Regulation and Standards and do they have the skills and knowledge to perform their duties in a safe and sanitary manner?
      • Unable to do assessment for invasive services onsite as operator does not have all required supplies for review. Invasive services including, microneedling, skin tag removal, microblading, permanent makeup are denied until a complete review of equipment, tools, supplies satisfactorily meets the Personal Services Regulations and Standards.
    • 20. Is reusable equipment disinfected properly?
      • Manufacturer instructions booklet for Dermapen states to use alcohol for disinfecting. Isopropyl alcohol has NPN but not DIN on label.Obtain a medicinal grade alcohol with DIN for use for disinfecting Dermapen device as per MIFU
    • 25. Are the equipment manufacturer's instructions for use of specific equipment available and followed?
      • Manufacturer's instruction manual are not available onsite for the following equipment:- RF device (KS-909) for skin tag removalThis service is to be discontinued until all invasive services are reviewed by Alberta Health Services.
    • 32. Are general nuisance conditions, other than those noted in other violations, being prevented at this personal services facility (Critical)?
      • Business has on front window advertising for Botox and Derma fillers. The operator does not have a qualified provider for administering botox injection with oversight by a Medical Director to provide these services (ie. authorized prescriber). Cease all botox and dermal filler services and remove all advertisements
    • 33. Are general nuisance conditions, other than those noted in other violations, being prevented at this personal services facility (Non-Critical)?
      • Facility provides complimentary drinks in reusable cups. Facility is not equipped with a kitchen facility for proper dishwashing or an approved area for preparing drinks. Do not use reusable cups for drinks offered onsite. All complimentary drinks are provided in single use cups from original bottles.
  2. Monitoring Inspection

    6 infractions

    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • Written facility procedures for the following were not onsite:1. Skin cleansing/ antiseptic use2. Decontamination procedures for cleaning and disinfecting dual purpose sink for handwashing and reprocessing equipment. 3. Procedures for accidental injury/cuts
    • 20. Is reusable equipment disinfected properly?
      • Reviewed disinfection process with use of PreEmpt CS20, operator had stated disinfect was diluted with water. This is in contravention to manufacturer's instruction for use. *PreEmpt CS20 directions for does not include a dilution step. Do not dilute the disinfectant before use.
    • 20. Is reusable equipment disinfected properly?
      • Manufacturer instructions booklet for Dermapen states to use alcohol for disinfecting. Alcohol used onsite (La Palm Isopropyl Alcohol) does not have a DIN as required by Health Canada to be used as a disinfectant for equipment. Obtain a medicinal grade alcohol with DIN for use for disinfecting Dermapen device as per MIFU
    • 25. Are the equipment manufacturer's instructions for use of specific equipment available and followed?
      • Manufacturer's instruction manual are not available onsite for the following equipment:- RF device (KS-909) for skin tag removal-
    • 32. Are general nuisance conditions, other than those noted in other violations, being prevented at this personal services facility (Critical)?
      • 1. Business online website has TCA listed as agent used for chemical peels. Operator did not have product onsite and stated not in use. TCA is not approved for service. *Remove TCA from listed chemical peel services.2. Business has on front window advertising for Botox and Dermafillers. These are not services provided by operator. Remove advertisement
    • 33. Are general nuisance conditions, other than those noted in other violations, being prevented at this personal services facility (Non-Critical)?
      • Facility provides complimentary drinks in reusable cups. Facility is not equipped with a kitchen facility for proper dishwashing or an approved area for preparing drinks. Do not use reusable cups for drinks offered onsite. All complimentary drinks are provided in single use cups from original bottles.
  3. Monitoring Inspection

    5 infractions

    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • Written facility procedures for the following were not onsite:1. Skin cleansing/ antiseptic use2. Decontamination procedures for cleaning and disinfecting dual purpose sink for handwashing and reprocessing equipment. 3. Procedures for accidental injury/cuts
    • 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
      • Consent records reviewed for services done by a former botox injector contracted by Tania. Records did not include 1. Injector's name on form as provider of service.2. Sterility information of the single use needles used3. Botox lot/exp of product used on clientsAll invasive procedures with disposable needles require record keeping of lot and expiry date for needles used on client records. This includes also for microneedling and microblading services.
    • 20. Is reusable equipment disinfected properly?
      • Manufacturer instructions booklet for Dermapen states to use alcohol for disinfecting. Alcohol used onsite (La Palm Isopropyl Alcohol) does not have a DIN as required by Health Canada to be used as a disinfectant for equipment. Obtain a medicinal grade alcohol with DIN for use for disinfecting Dermapen device as per MIFU
    • 25. Are the equipment manufacturer's instructions for use of specific equipment available and followed?
      • Manufacturer's instruction manual for RF device was not available onsite for review
    • 32. Are general nuisance conditions, other than those noted in other violations, being prevented at this personal services facility (Critical)?
      • 1. Individual wrapped disposable microblading needles onsite were beyond expiry date on packaging, dated expiry 2024-Dec2. Business online website has TCA listed as agent used for chemical peels. Operator did not have product onsite and stated not in use.
  4. Demand Inspection

    1 infraction

    • 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
      • Consent records reviewed for services done by a former botox injector contracted by Tania. Records did not include 1. Injector's name on form as provider of service.2. Sterility information of the single use needles used3. Botox lot/exp of product used on clients
  5. Demand Inspection

    1 infraction

    • 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
      • Consent records reviewed for services done by a former botox injector contracted by Tania. Records did not include 1. Injector's name on form as provider of service.2. Sterility information of the single use needles used3. Botox lot/exp of product used on clients
  6. Risk Management Inspection

    0 infractions

  7. Monitoring Inspection

    5 infractions

    • 08. Is hand hygiene performed by the personal services worker when required, in a proper manner and are provisions available to perform hand hygiene?
      • Washroom does not have soap or paper towel.
    • 20. Is reusable equipment disinfected properly?
      • Operator disinfecting microdermabrasion heads and waxing tweezers with a low level disinfectant, alcohol or Preempt RTU. Ensure CS20 is used on these tools.
    • 21. Is equipment that is intended to be sterile maintained sterile at the point of use?
      • Several needles for microneedling and PMU expired 2017/2018. Discarded onsite.
    • 26. Are cosmetic products appropriate for their intended use and being handled properly?
      • Several PMU inks were not labelled or were expired. Discarded onsite.
    • 27. Is the facility maintained in a visibly clean state and are environmental surfaces cleaned and disinfected properly?
      • The wax pots have a build up of wax and hair. Ensure these are cleaned.