The Centennial Centre - Main Pool

424069 Range Road 255 Ponoka AB T4J 1R8 · Aquatic Facility

10 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas aeruginosa was isolated in the bacteriological water sample submitted for the pool basin on April 10, 2026.Ensure that the pool is adequately treated for Pseudomonas aeruginosa and that a satisfactory bacteriological water sample is submitted to the Provincial Laboratory.
  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • - An unsatisfactory bacteriological water sample was received indicating the isolation of Pseudomonas aeruginosa, form the sample collected on March 31, 2026.
  5. Monitoring Inspection

    0 infractions

  6. Monitoring Inspection

    0 infractions

  7. Risk Management Inspection

    0 infractions

  8. Risk Management Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC = 180 CFU/mL
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH reading was 7.15Alkalinity reading was 93ppmFree available chlorine reading was 0.06ppmTotal chlorine reading was 0.19ppmCombined chlorine reading was 0.13ppmORP reading was 750mv The FAC reading of 0.06 ppm is unsatisfactory. Operator closed the pool and will rebalance water the following morning. Sodium hypochlorite can be added to increase chlorine levels in pool. Pool will only be re-opened once chemical parameters are satisfactory.A pool that has an ORP reading of 700mv or more may be operated with 0.5mg/l or more of free chlorine per liter and pH of no more than 7.3.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Observed a pool of water at the entrance and hallway of the mechanical room in the basement. Observed paint peeling off the walls near the pump panels, due to water damage.Operator mentioned a problem with the surge tank over spilling due to high bather load. Facility uses a gutter system.Operator mentioned a problem with the surge tank over spilling due to high bather load, and facility uses a gutter system.Operator will investigate the water spillage problem and contact a professional third party aquatic contractor or AHS FME department to do the overall assessment of the surge tank.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Water clarity was good.Water temperature reading was 31.7 CInformed operator that main pool water temperature should be maintained at 30 C or less.
  9. Monitoring Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC = 180 CFU/mL
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH reading was 7.15Alkalinity reading was 93ppmFree available chlorine reading was 0.06ppmTotal chlorine reading was 0.19ppmCombined chlorine reading was 0.13ppmORP reading was 750mv The FAC reading of 0.06 ppm is unsatisfactory. Operator closed the pool and will rebalance water the following morning. Sodium hypochlorite can be added to increase chlorine levels in pool. Pool will only be re-opened once chemical parameters are satisfactory.A pool that has an ORP reading of 700mv or more may be operated with 0.5mg/l or more of free chlorine per liter and pH of no more than 7.3.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Observed a pool of water at the entrance and hallway of the mechanical room in the basement. Observed paint peeling off the walls near the pump panels, due to water damage.Operator mentioned a problem with the surge tank over spilling due to high bather load. Facility uses a gutter system.Operator mentioned a problem with the surge tank over spilling due to high bather load, and facility uses a gutter system.Operator will investigate the water spillage problem and contact a professional third party aquatic contractor or AHS FME department to do the overall assessment of the surge tank.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • Water clarity was good.Water temperature reading was 31.7 CInformed operator that main pool water temperature should be maintained at 30 C or less.
  10. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC = 180 CFU/mL