The Fairview - Whirlpool

2288 Pine St, Vancouver BC V6J 4J8 · Hot Tub

Inspection summary

The Fairview - Whirlpool has been inspected 22 times by Vancouver Coastal Health since June 19, 2015. The most recent inspection, on August 26, 2025, recorded 2 infractions.

6 of 22 inspections on record found no infractions at all. No inspections are on record from the past 12 months. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 25 times across 14 separate inspections, most recently on August 26, 2025. For example: The pool alkalinity is properly maintained

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 5 times across 5 separate inspections, most recently on June 6, 2024. For example: Chemicals are stored in a safe manner and location

  • Equipment and utensilsLower risk

    Pumps, filters, chemical feeders and safety equipment such as lifebuoys, reaching poles and first-aid kits must be present and working. Missing safety equipment can matter a great deal in an emergency.

    Recorded 4 times across 4 separate inspections, most recently on April 12, 2023. For example: Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications

About this data

These results come from Vancouver Coastal Health, which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

22 inspections

  1. Routine

    2 infractions

    • The pool alkalinity is properly maintained
      • Total Alkalinity is too low and is not at a level to maintain chemically balanced pool water.
    • The operator maintains the pool in good repair.
      • Hot water provided in pool facilities is more than 49°C
  2. Routine Follow-up

    0 infractions

  3. Routine

    1 infraction

    • The pool alkalinity is properly maintained
      • Total Alkalinity is too low and is not at a level to maintain chemically balanced pool water.
  4. Routine Follow-up

    0 infractions

  5. Routine

    1 infraction

    • Chemicals are stored in a safe manner and location
      • Incompatible chemicals (Strong acids, strong bases, chlorine and organic chlorines) are not adequately separated.
  6. Routine

    1 infraction

    • The pool pH level is properly maintained
  7. Routine Follow-up

    0 infractions

  8. Routine

    6 infractions

    • The pool combined chlorine level is properly maintained
      • The pool combined chlorine level is greater than or equal to 1.0 ppm
    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • Pool water velocity and recirculation rate is properly maintained
    • Chemicals are stored in a safe manner and location
      • Chemicals are stored directly on the floor.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • Flow meter is not functioning correctly
      • The automatic chlorinator cannot produce a reliable chemical residual.
  9. Routine

    3 infractions

    • Pool water velocity and recirculation rate is properly maintained
    • The operator maintains the pool in good repair.
      • Nose of any step or ledge in the pool is not marked in a contrasting colour.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
  10. Routine

    4 infractions

    • The pool disinfectant is properly maintained
    • The pool alkalinity is properly maintained
    • Chemicals are stored in a safe manner and location
    • Pool rules are posted prominently within the pool enclosure
  11. Routine

    2 infractions

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
  12. Routine

    1 infraction

    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • Flow meter is not functioning correctly
  13. Routine

    0 infractions

  14. Routine Follow-up

    1 infraction

    • The pool combined chlorine level is properly maintained
      • The pool combined chlorine level is greater than or equal to 1.0 ppm
  15. Routine

    1 infraction

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
  16. Routine

    0 infractions

  17. Routine

    0 infractions

  18. Routine Follow-up

    1 infraction

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
  19. Routine

    2 infractions

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • Daily pool records are adequately maintained and available on site
      • Results of daily water testing is inadequately recorded: Free Available Chlorine, Combined Available Chlorine and pH is tested and recorded at least twice daily; Alkalinity and Cyanuric Acid is tested and recorded at least weekly.
  20. Routine

    3 infractions

    • The pool combined chlorine level is properly maintained
      • The pool combined chlorine level is greater than or equal to 1.0 ppm
    • Pool rules are posted prominently within the pool enclosure
      • Safety rules sign missing, incomplete, or not clearly visible to the public
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • A Ground Fault Interrupter is not present or functional on the heat trace and/or underwater light circuits
  21. Routine

    3 infractions

    • The pool combined chlorine level is properly maintained
      • The pool combined chlorine level is greater than or equal to 1.0 ppm
    • Chemicals are stored in a safe manner and location
    • Daily pool records are adequately maintained and available on site
  22. Routine

    2 infractions

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • Chemicals are stored in a safe manner and location
      • Chemicals are stored directly on the floor.