Skip to content
Loading map…

Thi Nails & Lounge

8-9-3045 Clayhill Rd Mississauga ON L5B 4L2 · Manicure / Pedicure

5 inspections

  1. Complaint

    1 infraction

    • Did operator provide a sharps container and properly dispose sharps?
      • Immediately after use, dispose all sharps (e.g., razor blades, credo blades, needles, lancets) in a sharps container that is located in close proximity to where the personal service is provided.
      • Do not take apart, bend, recap, recover, or otherwise manipulate needles, needle bars and other sharps after use on a client prior to disposal.
      • Dispose all sharps used for hairdressing in a sharps container that is located in close proximity to where the personal service is provided.
      • Provide a puncture and leak resistant sharps container with a fill line designed for the safe disposal of sharps compliant with the Canadian Standards Association.
      • Do not fill the sharps container past the maximum fill line.
      • Dispose sharps containers in accordance with the requirements of the Environmental Protection Act, its regulations and any other applicable law of Ontario.
      • Contract the services of a licensed medical/sharps waste disposal service to provide you with proper sharps containers and remove sharps from your business for proper disposal.
  2. Required

    2 infractions

    • Did operator provide a sharps container and properly dispose sharps?
      • Immediately after use, dispose all sharps (e.g., razor blades, credo blades, needles, lancets) in a sharps container that is located in close proximity to where the personal service is provided.
      • Do not take apart, bend, recap, recover, or otherwise manipulate needles, needle bars and other sharps after use on a client prior to disposal.
      • Dispose all sharps used for hairdressing in a sharps container that is located in close proximity to where the personal service is provided.
      • Provide a puncture and leak resistant sharps container with a fill line designed for the safe disposal of sharps compliant with the Canadian Standards Association.
      • Do not fill the sharps container past the maximum fill line.
      • Dispose sharps containers in accordance with the requirements of the Environmental Protection Act, its regulations and any other applicable law of Ontario.
      • Contract the services of a licensed medical/sharps waste disposal service to provide you with proper sharps containers and remove sharps from your business for proper disposal.
    • Did operator properly disinfect equipment and surfaces?
      • Intermediate-level disinfectant: Mix 20 ml (4 tsp) of 5.25% bleach with 500 ml (2 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 5 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • Pedicure basin with single use disposable liner: Clean the basin with detergent, water and scrub brush after every use. Clean and low level disinfect at the end of the day. If the liner tears or breaks while in use, clean and intermediate level disinfect the basin immediately after use. If a magnetic jet cover is used in the spa water, it must be cleaned and intermediate level disinfected after every use. (Show More)
      • Pedicure basin without recirculation: Clean and intermediate-level disinfect pipe-less basin and all removable parts (if applicable) after every use. First clean with detergent, water and a scrub brush. Rinse with clean water and intermediate level disinfect. Rinse again with clean water.
      • Pedicure basin filter/screen (e.g., magnet screens): Remove, dismantle, clean then intermediate level disinfect after every use.
  3. Required

    0 infractions

  4. Required

    3 infractions

    • Did operator discard single use equipment immediately after each use?
      • Discard single use equipment immediately after use.
      • Ensure that all equipment designed for single use or made of a material that does not withstand cleaning and disinfection or sterilization is discarded immediately after use (e.g., nail files, buffer blocks, gloves, sponges, applicator sticks, ear piercing adapters).
    • Did operator properly disinfect equipment and surfaces?
      • Intermediate-level disinfectant: Mix 20 ml (4 tsp) of 5.25% bleach with 500 ml (2 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 5 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
    • Did operator maintain client records for invasive services?
  5. Required

    2 infractions

    • Did operator discard single use equipment immediately after each use?
      • Discard single use equipment immediately after use.
      • Ensure that all equipment designed for single use or made of a material that does not withstand cleaning and disinfection or sterilization is discarded immediately after use (e.g., nail files, buffer blocks, gloves, sponges, applicator sticks, ear piercing adapters).
      • Roll-on wax cartridge must be used for one client only and discarded immediately after use. Do not reuse and/or refill roll-on wax cartridges.
    • Did operator keep disinfection records?
      • Keep disinfection records that include: name of the disinfectant, concentration of disinfectant, date prepared, and date discarded.
      • Keep disinfection records for one year at personal service setting and keep readily available for an additional two years.
      • Provide the records to a medical officer of health or public health inspector on request.