Town of Stony Plain - Water Spray Park

5210 55 Avenue Stony Plain AB T7Z 1Y1 · Aquatic Facility

20 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The HPC count from sample collected August 18, 2026, was reported at 390 CFU/mL.
  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • REPEAT VIOLATION: The HPC count was elevated this week (sample date: August 4, 2026). HPC value: 290 CFU/mL.The recirculation system is required to be taken out of service immediately. The spray park may remain operational provided it is supplied with municipal water and operated on a straight-to-waste basis, with no recirculation of water.
  5. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • REPEAT VIOLATION: The HPC count was elevated this week (sample date: July 28, 2026). HPC value: 230 CFU/mL.
  6. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The HPC count was elevated this week (sample date: July 21, 2026). HPC value: 190 CFU/mL.
  7. Risk Management Inspection

    0 infractions

  8. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • July 7, 2026, water sample returned with elevated HPC at 3070 CFU/mLPool operator to shock chlorinate the recirculation system and submit a new sample.
  9. Risk Management Inspection

    0 infractions

  10. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample submitted from this spray park on June 17, 2026, showed the Heterotrophic Plate Count was elevated (190 CFU/mL)
  11. Monitoring Inspection

    0 infractions

  12. Demand Inspection

    3 infractions

    • 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
      • One of the 3 sand filters was not operational at time of inspection.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The probe for ORP was not working at time of inspection.
    • 09. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Critical)?
      • PHI could not get a reading on chlorine levels or total alkalinity (too high)
  13. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The probe for ORP was not working at time of inspection.
  14. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The bacteriological water sample from this spray park had a presence of total coliform bacteria in sample from August 26, 2025.Pool operator will run the spray park as a flow through system (no recirculation) until a satisfactory water sample returns.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The probe for ORP was not working at time of inspection.
  15. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas aeruginosa was present in the east side bacteriological water sample.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The probe for ORP was not working at time of inspection.
  16. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The probe for ORP was not working at time of inspection.
  17. Risk Management Inspection

    0 infractions

  18. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample showed HPC exceedance. 170 CFU/mL
  19. Risk Management Inspection

    0 infractions

  20. Monitoring Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH measured at 8.26.