Tru by Hilton Edmonton Windermere - Swimming Pool

6025 Andrews Way SW Edmonton AB T6W 3S9 · Aquatic Facility

16 inspections

  1. Demand Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was a discrepancy between the manual reading for pH 7.51, and the automated controller reading for pH 7.1. It was addressed during the inspection.
  2. Demand Inspection

    2 infractions

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The main drain outlet covers (Hayward WG 1032 BLV 12*12) expired on January 11, 2026. Replace the main drains outlets.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An updated anti-entrapment compliance plan assessing the entrapment risks had not been developed and was not available for review. Develop a new anti-entrapment compliance plan reflecting the current equipment and submit the plan for review to Environmental Public Health.
  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The microbiological water sample submitted on August 1, 2025, was unsatisfactory: HPC 210 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  5. Risk Management Inspection

    0 infractions

  6. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample submitted on 20/06/2025 was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the sample 25EN-192E00235 submitted on July 11, 2025, was unsatisfactory: Total coliforms were present.
  7. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • The microbiological water sample submitted on 20/06/2025 was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
  8. Risk Management Inspection

    0 infractions

  9. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the sample 25EN-115E00133 submitted on April 25, 2025, was unsatisfactory: Total coliforms were present.
  10. Risk Management Inspection

    0 infractions

  11. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the sample 25EN-101E00113 submitted on April 11, 2025, was unsatisfactory: Total coliform was present.
  12. Risk Management Inspection

    0 infractions

  13. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Weirs were missing in the skimmers. Install missing weirs.
  14. Monitoring Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 16.29 gpm/sq ft based on a filtration area of 4.91 sq ft. Ensure that the rate of filtration does not exceed 15 gpm/sq ft. Note flow rate should not exceed 74 gpm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Weirs were missing in the skimmers. Install missing weirs.
  15. Risk Management Inspection

    0 infractions

  16. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the sample WE-23-0131524 submitted on December 8, 2023, was unsatisfactory: Total coliforms present.