Waters Edge Development - Pool

35 - 55101 Ste. Anne Trail Lac Ste Anne County AB T0E 1A1 · Aquatic Facility

6 inspections

  1. Risk Management Inspection

    0 infractions

  2. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity readings consistently exceeded 200 ppm during inspector testing, surpassing the recommended range of 60–180 ppm. Operator records showed slightly lower values at 190 ppm but still above the ideal range. Combined chlorine levels were measured at 0.12 ppm by the operator and 0.62 ppm by the inspector.Information on alkalinity balancing was provided by text message following the inspection. Values should continue to be monitored and adjusted as needed.It was also noted that some of the testing tablets for the pool operators Pool Lab 1.0 photmeter were expired. Operator asked to review the supply and update/replace any expired testing equipment.
  3. Monitoring Inspection

    0 infractions

  4. Risk Management Inspection

    0 infractions

  5. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • TC PRESENT Note pool was closed at time of follow up. Pool's chemical parameters reviewed. Pool sample results will be reassessed the following week.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC present @ 600 CFU/ml.Note pool was closed at time of follow up. Pool's chemical parameters reviewed. Pool sample results will be reassessed the following week.
  6. Monitoring Inspection

    0 infractions