Whispering Pines Motel
10456 Lakeshore Rd, Grand Bend ON N0M 1T0 · Seasonal Class B Public Pool
6 inspections
- Follow-up
1 infraction
- The pool is rendered inaccessible to persons who are not involved with its operation, inspection or maintenance, except during the daily use period.
- Fail to ensure the pool is rendered inaccessible to persons when the pool facility is closed.
- The pool is rendered inaccessible to persons who are not involved with its operation, inspection or maintenance, except during the daily use period.
- Required
7 infractions
- A manual pool test kit is available to determine water chemistry.
- Fail to provide an approved manual pool test kit to determine water chemistry.
- Where cyanurate stabilization is maintained in outdoor pools, free available chlorine (FAC) reads a minimum of 1.0 ppm and not more than 10 ppm, in association with a cyanuric acid concentration of not greater than 60 ppm.
- Fail to maintain stabilized FAC at 1.0 - 10 ppm. Close pool.
- Fail to maintain cyanuric acid concentration (stabilizer) of 60 ppm of less. Close pool.
- Testing in accordance with the Regulation is conducted during the daily use period (TA, pH, FAC, TC, Br, Water Clarity).
- Fail to ensure that testing for chlorine or bromine residual, total chlorine, total alkalinity, pH, and water clarity are manually tested one half hour before bathers are admitted and at intervals not greater than 2 hours while the pool is in use (no automatic sensing device used).
- Make-up water is added to the pool during each operating day in a minimum amount of 15L per bather as determined by a water meter installed for that purpose.
- Fail to ensure that a minimum of 15 L/bather of make-up water is added to the pool each operating day.
- Operator conducted the required inspections and recorded the results. Records are retained for a period of 1 year.
- Fail to record the time of day the water, gravity and suction outlet covers are inspected at least once within each period of 30 operating days.
- Fail to close the pool when the outlet covers are found to be loose or missing.
- Fail to record the time of day the ground current leakage detecting and de-energizing devices are tested either monthly or according to the manufacturer's instructions.
- Fail to record the time of day the emergency stop button test, if applicable, was performed once within each period of 30 operating days.
- Fail to record the cyanuric acid concentration not less than once every week.
- Fail to ensure all records are completed and signed by operator.
- Fail to retain records for a period of 1 year and made available for viewing by a public health inspector at any time.
- Safety equipment, in accordance with the Regulation, is provided and conveniently located for emergency use at the pool.
- Fail to have a buoy line when the Class B pool has a slope of more than 8%. Close pool.
- Written emergency and operational procedures and instructions are available at the pool to be implemented in the event of an emergency, accident or injury in the pool.
- Fail to have written emergency and operational procedures and instructions available at the pool.
- A manual pool test kit is available to determine water chemistry.
- Follow-up
1 infraction
- A manual pool test kit is available to determine water chemistry.
- Fail to provide an approved manual pool test kit to determine water chemistry.
- A manual pool test kit is available to determine water chemistry.
- Required
7 infractions
- The owner/operator notified the public health unit, in writing, at least 14 days before the public pool was put into use after construction/alteration or before opening/reopening after any closure that lasts more than 4 weeks.
- Fail to notify public health at least 14 days prior to reopening a pool that had been closed for more than 4 weeks.
- Every facility has a designated operator that is trained in the pool's operation and maintenance, filtration systems, water chemistry and all relevant safety and emergency procedures.
- Fail to have a designated operator trained in pool operation and maintenance, filtration systems, water chemistry and all relevant safety and emergency procedures.
- The pool is rendered inaccessible to persons who are not involved with its operation, inspection or maintenance, except during the daily use period.
- Fail to ensure the pool is rendered inaccessible to persons when the pool facility is closed.
- A manual pool test kit is available to determine water chemistry.
- Fail to provide an approved manual pool test kit to determine water chemistry.
- Testing in accordance with the Regulation is conducted during the daily use period (TA, pH, FAC, TC, Br, Water Clarity).
- Fail to ensure that testing for chlorine or bromine residual, total chlorine, total alkalinity, pH, and water clarity are manually tested one half hour before bathers are admitted and at intervals not greater than 2 hours while the pool is in use (no automatic sensing device used).
- A land line emergency telephone is provided, easily accessible and directly connected to an emergency service or to the local telephone utility.
- Fail to have an emergency telephone that is directly connected to an emergency service or to the local telephone utility. Close pool.
- Written emergency and operational procedures and instructions are available at the pool to be implemented in the event of an emergency, accident or injury in the pool.
- Fail to have written emergency and operational procedures and instructions available at the pool.
- The owner/operator notified the public health unit, in writing, at least 14 days before the public pool was put into use after construction/alteration or before opening/reopening after any closure that lasts more than 4 weeks.
- Required
0 infractions
- Required
0 infractions