  1. Risk Management Inspection

    0 infractions

  2. Risk Management Inspection

    4 infractions

    • 20. Is reusable equipment disinfected properly?
      • No high-level disinfectant as available for disinfection of semi-critical tools (tweezers). The semi-critical tools must be disinfected by soaking in a high-level disinfectant.
    • 20. Is reusable equipment disinfected properly?
      • No records of testing of high-level disinfectant were available, and no testing of disinfectant has been conducted as required.
    • 20. Is reusable equipment disinfected properly?
      • No test strips were available to test the concentration of high-level disinfectant. Obtain the appropriate strips.
    • 30. Is the reprocessing area of a personal service facility that uses reusable equipment properly designed, managed and maintained to ensure the safety of clients?
      • The reprocessing area was located in the bathroom. Bathroom sink was used for tools washing. Provide a designated reprocessing sink, which is not located in the bathroom.
  3. Initial Inspection

    5 infractions

    • 10. Is cleansing and antisepsis of skin and mucous membrane performed in accordance to written procedures and are suitable products being used?
      • No antiseptic was used prior to eyeliner permanent make-up services.
    • 20. Is reusable equipment disinfected properly?
      • No high-level disinfectant as available for disinfection of semi-critical tools (tweezers). The semi-critical tools must be disinfected by soaking in a high-level disinfectant.
    • 20. Is reusable equipment disinfected properly?
      • No records of testing of high-level disinfectant were available, and no testing of disinfectant has been conducted as required.
    • 20. Is reusable equipment disinfected properly?
      • No test strips were available to test the concentration of high-level disinfectant. Obtain the appropriate strips.
    • 30. Is the reprocessing area of a personal service facility that uses reusable equipment properly designed, managed and maintained to ensure the safety of clients?
      • The reprocessing area was located in the bathroom. Bathroom sink was used for tools washing. Provide a designated reprocessing sink, which is not located in the bathroom.