Skip to content
Loading map…

YMCA of Medicine Hat - Ladies Hot Tub

150 Ash Avenue SE Medicine Hat AB T1A 3A9 · Aquatic Facility

9 inspections

  1. Risk Management Inspection

    0 infractions

  2. Risk Management Inspection

    0 infractions

  3. Risk Management Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The pH measured at 8.03. *Ensure pH is between 6.8-7.6.
  4. Monitoring Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The pH measured at 8.03. *Ensure pH is between 6.8-7.6.
  5. Monitoring Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • 1. Bacteriological water samples are at times being collected from the spigot of the automated system. 2. Aseptic sampling techniques are not being employed: (i) Handwashing is not performed prior to sampling. (ii) The bottle cap is not carefully and properly removed/"pinched" to avoid contaminating the sterile insides of both the cap and the bottle. (iii) The bottle is held near its mouth and not towards the bottom. (iv) The direction of the sweep facilitates contamination.Advised the operator to always collect samples directly from the basin.The aseptic sweep method for bacteriological water sampling is demonstrated, and the operator practiced same afterwards.
  6. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas aeruginosa has been isolated from the hot tub.The sample was collected on June 10, 2025.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC is slightly elevated (140 CFU/mL).The sample was collected on June 10, 2025.
  7. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC is moderately elevated (830 CFU/mL).The sample was collected on March 14, 2025.
  8. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC is moderately elevated (850 CFU/mL).The sample was collected on March 11, 2025.
  9. Monitoring Inspection

    0 infractions