Amour Body Contour has been inspected 2 times by Peel Public Health (Region of Peel) since October 14, 2025. The most recent inspection, on August 13, 2026, recorded 1 infraction.

None of the 2 inspections on record were free of infractions. In the past 12 months there was 1 inspection with 1 infraction recorded. All recorded findings relate to upkeep, equipment or paperwork rather than direct infection-control risks to clients.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for clients. In personal service settings like salons, spas and tattoo studios, higher-risk findings are the ones that could spread infection from one client to the next, through broken skin, blood or instruments that were not properly cleaned and sterilized.

  • Equipment and utensilsLower risk

    Instruments, chairs, tables and footbaths must be made of materials that can be cleaned, kept in good repair and stored so they stay clean. Single-use items such as nail files, buffers, razors and needles must be thrown away after each client.

    Recorded 2 times across 2 separate inspections, most recently on August 13, 2026. For example: Did operator maintain setting and work surfaces in a safe and sanitary condition?

  • Other findingsLower risk

    Findings that do not fit the categories above, such as follow-ups that confirm an earlier violation was corrected, or requirements specific to this type of facility.

    Recorded once on October 14, 2025. For example: Did operator properly use and maintain cleaning and disinfecting products?

About this data

These results come from Peel Public Health (Region of Peel), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

2 inspections

  1. Required

    1 infraction

    • Did operator maintain setting and work surfaces in a safe and sanitary condition?
      • Remove equipment and supplies no longer used/required for the operation of the setting.
  2. Required

    2 infractions

    • Did operator properly disinfect equipment and surfaces?
      • Provide a low-level disinfectant and ensure it is easily accessible.
      • Low-level disinfectant: Mix 2 ml (½ tsp) of 5.25% bleach with 1 L (4 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 10 minutes. Prepare a new bleach and water solution daily.
      • Low-level disinfect equipment and surfaces that do not directly contact the client, or contact only hair or intact skin (e.g., combs, reusable handles/holders for blades, magnifying glasses, equipment covered with single use disposable plastic liner, client chairs, client beds).
      • Clean and low-level disinfect low-risk environmental surfaces (e.g., manicure/waxing tables, chairs, or beds that are covered with a single-use towel/ cover) at the end of the day or when visibly soiled.
      • Provide an intermediate-level disinfectant and ensure it is easily accessible.
      • Intermediate-level disinfectant: Mix 20 ml (4 tsp) of 5.25% bleach with 500 ml (2 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 5 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • Intermediate-level disinfect equipment such as nail clippers, cuticle nippers, nail drill bits, ear piercing device, single-use ink caps, tweezers and scissors used in hair removal services.
      • Do not spray or wipe equipment and surfaces with 70-90% alcohol. Alcohol evaporates quickly and will not reach the 10 minute contact time. Equipment must be fully immersed in the alcohol.
      • Fully immerse equipment in 70-90% alcohol for 10 minutes and then discard the alcohol. Do not re-use the alcohol. When soaking equipment, new alcohol must be used for each batch of equipment.
      • Provide a high-level disinfectant and ensure it is easily accessible.
      • High-level disinfectant: Mix 125 ml (½ cup) of 5.25% bleach with 1 L (4 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 10 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • High-level disinfect equipment such as grater-style foot files, comedone extractor with loops on both ends, and diamond microdermabrasion tips.
    • Did operator properly use and maintain cleaning and disinfecting products?
      • Provide a disinfecting container with a lid or cover that is capable of fully immersing equipment in the disinfectant.
      • Use only 70-90% isopropyl or ethyl alcohol.
      • Dry equipment prior to disinfection to prevent diluting the disinfectant.
      • Rinse the disinfected equipment where manufacturer's instructions require or when bleach (sodium hypochlorite) is used.
      • Prepare a new bleach and water solution daily.
      • Ensure prepared disinfectant solutions are not topped up with fresh solution (i.e., do not add new solution to the current solution). Containers must be emptied, cleaned, disinfected, rinsed, and dried before refilling.
      • Follow manufacturer's instructions for contact times of disinfectant product(s), where available.
      • Ensure that disinfectants used in a personal service setting are accompanied by a drug identification number (DIN), natural product number (NPN) or Medical Devices Active Licence Listing (MDALL) assigned by Health Canada (exception is bleach/sodium hypochlorite); and used as per the manufacturer’s instructions, where available. (Show More)