  1. Demand Inspection

    3 infractions

    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • Written procedures for skin cleansing, use of antiseptic and post-care procedures are required. Templates attached to the report. Please complete and send to PHI.
    • 26. Are cosmetic products appropriate for their intended use and being handled properly?
      • "Not observed during inspection"Expired hydrafacial products were observed during the inspection. - Ensure to go through the products at regular intervals to ensure expired products are removed.
    • 32. Are general nuisance conditions, other than those noted in other violations, being prevented at this personal services facility (Critical)?
      • 1. Saline present for neuromodulator reconstitution was 0.9% bacteriostatic sodium chloride with a preservative. Please purchase 0.9% sterile, preservative-free saline, as indicated in the manufacturer’s instructions for the neuromodulator (Dysport).2.Sterile tubes used for centrifuge (PRP) were expired. Please purchase new sterile tubes.
  2. Monitoring Inspection

    1 infraction

    • 26. Are cosmetic products appropriate for their intended use and being handled properly?
      • Expired hydrafacial products were observed during the inspection. - Ensure to go through the products at regular intervals to ensure expired products are removed.
  3. Risk Management Inspection

    0 infractions

  4. Initial Inspection

    1 infraction

    • 20. Is reusable equipment disinfected properly?
      • Alcohol is used for disinfecting clean-in-place equipment. Please obtain an appropriate disinfectant that has a Drug Identification Number.