Skip to content
Loading map…

Canada Medlaser

1705 Lakeshore Rd W Mississauga ON L5J 1J4 · Aesthetics

3 inspections

  1. Required

    0 infractions

  2. Required

    0 infractions

  3. Required

    2 infractions

    • Did operator properly disinfect equipment and surfaces?
      • Provide an intermediate-level disinfectant and ensure it is easily accessible.
      • Intermediate-level disinfectant: Mix 20 ml (4 tsp) of 5.25% bleach with 500 ml (2 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 5 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • Do not spray or wipe equipment and surfaces with 70-90% alcohol. Alcohol evaporates quickly and will not reach the 10 minute contact time. Equipment must be fully immersed in the alcohol.
      • Fully immerse equipment in 70-90% alcohol for 10 minutes and then discard the alcohol. Do not re-use the alcohol. When soaking equipment, new alcohol must be used for each batch of equipment.
    • Did operator properly use and maintain cleaning and disinfecting products?
      • Do not use expired disinfectants.