Canalta Hotel - Swimming Pool

500 - 6700 46 Street Olds AB T4H 0A2 · Aquatic Facility

17 inspections

  1. Monitoring Inspection

    0 infractions

  2. Monitoring Inspection

    0 infractions

  3. Risk Management Inspection

    0 infractions

  4. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Volume: 24,825 usgFlow Rate: 96 gpmTurnover: 4.3 hrAn automated control system is installed and functioning.*Operator noted the filter needed to be backwashed, which was the cause of the reduced flow rate. Backwash filter and adjust flow rate to at least 105 gpm to meet the required 4 hour turnover time.
  5. Risk Management Inspection

    0 infractions

  6. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Vol: 24,825 usgFlow: 92 gpmTurnover: 4.5 hrNote: Minimum flow rate to meet 4 hour turnover time is: 105 gpm.Adjust flow rate to meet or exceed 105 gpm.
  7. Risk Management Inspection

    0 infractions

  8. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • the water sample collected on November 13, 2024, which had the following results: - Total Coliform bacteria - ABSENT - HPC bacteria - 2870 CFU/mL.This is an unsatisfactory result.The following steps were given to the operator, they were: - to close the main pool from public use immediately. - to shock chlorinate the pool when all persons are removed. - after shock chlorinating - to backwash the filter - re-balance the water chemistry - the pool can then be re-opened to the public - resample on your regular sampling day.
  9. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • the water sample collected on November 13, 2024, which had the following results: - Total Coliform bacteria - ABSENT - HPC bacteria - 2870 CFU/mL.This is an unsatisfactory result.The following steps were given to the operator, they were: - to close the main pool from public use immediately. - to shock chlorinate the pool when all persons are removed. - after shock chlorinating - to backwash the filter - re-balance the water chemistry - the pool can then be re-opened to the public - resample on your regular sampling day.
  10. Demand Inspection

    0 infractions

  11. Monitoring Inspection

    0 infractions

  12. Monitoring Inspection

    0 infractions

  13. Risk Management Inspection

    0 infractions

  14. Risk Management Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • HPC result 450 / 100mlSample Date: 4 Oct 2023Accession NUmb: WE-23-0107761
  15. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • HPC result 450 / 100mlSample Date: 4 Oct 2023Accession NUmb: WE-23-0107761
  16. Risk Management Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • HPC result 450 / 100mlSample Date: 4 Oct 2023Accession NUmb: WE-23-0107761
  17. Monitoring Inspection

    0 infractions