Skip to content
Loading map…

CKD Salon

1920 37 Street SW Calgary AB T3E 3A3 · Personal Services

8 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    6 infractions

    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • No written procedures for accidental skin cut or puncture and skin cleansingProvide written procedures on client care on the event of an accidental skin cut or puncture.
    • 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
      • Semi-permanent tattoos: Lot number of the needle was not recorded on the client's file.Write down lot number for the needle for the semi-permanent tattoo.Sterility assurance documentation is required to have on record and maintained for 2 years. It must include the lot number, and the expiration of the needle attached to the client's records.
    • 13. Is single-use or uncleanable equipment being used as intended (Critical)?
      • Found used nail filers in the manicure station drawer. Discard single use items after use.
    • 16. Is reusable equipment handled and stored properly (Non-Critical)?
      • Towels and blanket were not treated with heat and not sure if a disinfectant was used to wash towels and blanket.Use heat to dry or use a disinfectant in the washer.
    • 17. Is reusable equipment cleaned properly (Critical)?
      • Manicure and pedicure tools were dried in the same rack as the hair tools. Provide a separate rack to dry the manicure and pedicure tools.
    • 20. Is reusable equipment disinfected properly?
      • Lysol with DIN was used to disinfect foot bath. NO TEST STRIPS AVAILABLE TO TEST THE QUAT CONCENTRATION TO DETERMINE IF THE RIGHT CONCENTRATION IS USED. PREempt RTU---DO NOT NEED TEST STRIPS Mr. Clean or Lysol All Purpose Cleaner---REQUIRED TEST STRIPS TO TEST THE QUAT SANITIZER CONCENTRATION.Please note that Mr. Clean and Lysol All Purpose Cleaner have a 10-minutes contact time. Leave Mr. Clean and Lysol in the foot bath for 10 minutes before rinsing.PREempt RTU has a contact time of 3-minutes
  3. Risk Management Inspection

    6 infractions

    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • No written procedures for accidental skin cut or puncture and skin cleansingProvide written procedures on client care on the event of an accidental skin cut or puncture.
    • 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
      • Semi-permanent tattoos: Lot number of the needle was not recorded on the client's file.Write down lot number for the needle for the semi-permanent tattoo.Sterility assurance documentation is required to have on record and maintained for 2 years. It must include the lot number, and the expiration of the needle attached to the client's records.
    • 13. Is single-use or uncleanable equipment being used as intended (Critical)?
      • Found used nail filers in the manicure station drawer. Discard single use items after use.
    • 16. Is reusable equipment handled and stored properly (Non-Critical)?
      • Towels and blanket were not treated with heat and not sure if a disinfectant was used to wash towels and blanket.Use heat to dry or use a disinfectant in the washer.
    • 17. Is reusable equipment cleaned properly (Critical)?
      • Manicure and pedicure tools were dried in the same rack as the hair tools. Provide a separate rack to dry the manicure and pedicure tools.
    • 20. Is reusable equipment disinfected properly?
      • Lysol with DIN was used to disinfect foot bath. NO TEST STRIPS AVAILABLE TO TEST THE QUAT CONCENTRATION TO DETERMINE IF THE RIGHT CONCENTRATION IS USED. PREempt RTU---DO NOT NEED TEST STRIPS Mr. Clean or Lysol All Purpose Cleaner---REQUIRED TEST STRIPS TO TEST THE QUAT SANITIZER CONCENTRATION.Please note that Mr. Clean and Lysol All Purpose Cleaner have a 10-minutes contact time. Leave Mr. Clean and Lysol in the foot bath for 10 minutes before rinsing.PREempt RTU has a contact time of 3-minutes
  4. Monitoring Inspection

    6 infractions

    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • No written procedures for accidental skin cut or puncture and skin cleansingProvide written procedures on client care on the event of an accidental skin cut or puncture.
    • 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
      • Semi-permanent tattoos: Lot number of the needle was not recorded on the client's file.Write down lot number for the needle for the semi-permanent tattoo.Sterility assurance documentation is required to have on record and maintained for 2 years. It must include the lot number, and the expiration of the needle attached to the client's records.
    • 13. Is single-use or uncleanable equipment being used as intended (Critical)?
      • Found used nail filers in the manicure station drawer. Discard single use items after use.
    • 16. Is reusable equipment handled and stored properly (Non-Critical)?
      • Towels and blanket were not treated with heat and not sure if a disinfectant was used to wash towels and blanket.Use heat to dry or use a disinfectant in the washer.
    • 17. Is reusable equipment cleaned properly (Critical)?
      • Manicure and pedicure tools were dried in the same rack as the hair tools. Provide a separate rack to dry the manicure and pedicure tools.
    • 20. Is reusable equipment disinfected properly?
      • 1) No disinfectant was available to disinfect the manicure and pedicure tools. Container of Barbicide was placed on the manicure station.Remove barbicide from the manicure station (CDI)Provide PREempt CS20 for manicure and pedicure tools and disinfectant spray for the clippers.2) Lysol with DIN was used to disinfect foot bath. NO TEST STRIPS AVAILABLE TO TEST THE QUAT CONCENTRATION TO DETERMINE IF THE RIGHT CONCENTRATION IS USED. PREempt RTU---DO NOT NEED TEST STRIPS Mr. Clean or Lysol All Purpose Cleaner---REQUIRED TEST STRIPS TO TEST THE QUAT SANITIZER CONCENTRATION.Please note that Mr. Clean and Lysol All Purpose Cleaner have a 10-minutes contact time. Leave Mr. Clean and Lysol in the foot bath for 10 minutes before rinsing.PREempt RTU has a contact time of 3-minutes
  5. Demand Inspection

    1 infraction

    • 29. Is the facility properly constructed and maintained to allow for the safe and sanitary provision of personal services (Non-Critical)?
      • There was a shag rug under the permanent make-up work area.-remove the rug. Ensure all surfaces are smooth, durable, non-absorbent and washable.
  6. Demand Inspection

    1 infraction

    • 29. Is the facility properly constructed and maintained to allow for the safe and sanitary provision of personal services (Non-Critical)?
      • There was a shag rug under the permanent make-up work area.-remove the rug. Ensure all surfaces are smooth, durable, non-absorbent and washable.
  7. Demand Inspection

    1 infraction

    • 29. Is the facility properly constructed and maintained to allow for the safe and sanitary provision of personal services (Non-Critical)?
      • There was a shag rug under the permanent make-up work area.-remove the rug. Ensure all surfaces are smooth, durable, non-absorbent and washable.
  8. Initial Inspection

    2 infractions

    • 21. Is equipment that is intended to be sterile maintained sterile at the point of use?
      • Single use needs for permanent make-up did not state "STERILE". Do not use.
    • 29. Is the facility properly constructed and maintained to allow for the safe and sanitary provision of personal services (Non-Critical)?
      • There was a shag rug under the permanent make-up work area.-remove the rug. Ensure all surfaces are smooth, durable, non-absorbent and washable.