Dillon Cove Pool
1 Parker Ln Nobel ON P0G 1G0 · Outdoor - Swimming Pool
5 inspections
- Compliance (Required)
5 infractions
- Minimum amount of make-up water added daily (15L/bather)
- Fail to ensure make-up water (minimum 15 L/bather) is added to the pool daily
- Ensure minimum make-up water of 15L/bather is added to the pool daily
- Daily records completed, signed and available for viewing
- Fail to complete and sign records daily
- Fail to record Cl (free and total) residual ½ hr before opening & every 2 hrs (without automatic sensing device) or 4 hrs (with automatic sensing device) while pool open
- Fail to record pH residual ½ hr before opening & every 2 hrs (without automatic sensing device) or 4 hrs (with automatic sensing device) while pool open
- Fail to record time of day for testing of emergency telephone
- Fail to record total alkalinity ½ hr before opening and every two hours while pool is open (every 4 hours with automatic sensing device)
- Fail to record water clarity observation ½ hr before opening and every two hours while pool is open (every 4 hours with automatic sensing device)
- Ensure daily records are completed, signed and available for viewing by MOH or PHI at any time
- Other records signed and completed
- Fail to record water outlet covers inspection (at least once every 30 operating days)
- If not equipped with an automatic sensing device, manual tests conducted 1/2 hour prior to opening and at least every 2 hours until the daily use period has ended (total alkalinity, pH value, free available chlorine, total chlorine or bromine residual and water clarity)(water temperature if a hot water pool => 35°C)
- Fail to test total alkalinity at least every 2 hours
- Fail to test pH at least every 2 hours
- Fail to test free available chlorine (FAC) at least every 2 hours
- Fail to check water clarity at least every 2 hours
- Ensure all tests are completed at least every 2 hours
- Manual tests conducted ½ hr prior to opening: total alkalinity, pH value, free available chlorine, total chlorine or bromine residual and water clarity (water temperature if a hot water pool => 35°C)
- Fail to complete manual testing ½ hr prior to opening
- Minimum amount of make-up water added daily (15L/bather)
- Re-inspection
2 infractions
- Proper test kit is available for use to determine water chemistry (no dip and read strips)
- Fail to provide proper test kit to determine water chemistry
- Provide proper test kit to determine water chemistry
- Safety equipment available and in good repair
- Fail to provide a fully supplied first-aid kit
- Proper test kit is available for use to determine water chemistry (no dip and read strips)
- Re-inspection
5 infractions
- Premises is maintained free from every serious condition that may be a health hazard
- CLOSE POOL
- pH is within range of 7.2 to 7.8
- CLOSE POOL
- Fail to maintain pH within acceptable range
- Ensure pH is maintained within range of 7.2 - 7.8
- Proper test kit is available for use to determine water chemistry (no dip and read strips)
- Fail to provide proper test kit to determine water chemistry
- Provide proper test kit to determine water chemistry
- Other records signed and completed
- Fail to test ground current leakage detecting and de-energizing devices monthly or according to manufacturer’s instructions, whichever is more frequent
- Required notice(s) are provided and accurate
- Fail to indicate the location of the emergency telephone on the required notice
- Fail to indicate the maximum number of bathers permitted on the deck and in the water at any time on the required notice(s)
- Premises is maintained free from every serious condition that may be a health hazard
- Compliance (Required)
2 infractions
- Proper test kit is available for use to determine water chemistry (no dip and read strips)
- Total alkalinity within range of 60-180 ppm
- Fail to maintain total alkalinity within range of 60-180 ppm
- Ensure total alkalinity within range of 60-180 ppm
- Compliance (Required)
0 infractions