Skip to content
Loading map…

Discovery Place - Outdoor Pool

1890 Valley Farm Rd, Pickering ON L1V 6B4 · Pool - Class B

3 inspections

  1. Routine

    2 infractions

    • pH is within range of 7.2 to 7.8
      • Fail to maintain pH within acceptable range
      • Operator to ensure pH is maintained within range of 7.2 to 7.8
    • Safety equipment available and in good repair
      • Fail to provide a fully supplied first-aid kit
      • Operator to provide a first-aid kit with contents as prescribed by the Regulation
  2. Re-Inspection

    3 infractions

    • Minimum amount of make-up water added daily
      • Fail to ensure make-up water (minimum 15 L/bather) is added to the pool daily
      • Operator to ensure minimum make-up water of 15 L/bather is added to the pool daily
    • Daily records completed, signed and available for viewing
      • Fail to record reading of the make-up water meter
      • Fail to record total number of bathers admitted to pool each day
      • Operator to ensure daily records are completed, signed and available for viewing by Medical Officer of Health or Public Health Inspector at any time
    • Other records signed and completed
      • Fail to determine cyanurate stabilization at least 1/week
      • Fail to record water outlet covers inspection (at least once every 30 operating days)
      • Operator to ensure cyanurate stabilization is determined and recorded at least 1/week
      • Operator to ensure water outlet covers are inspected and recorded (at least once every 30 operating days) along with time of day test was completed
  3. Routine

    4 infractions

    • Minimum amount of make-up water added daily
      • Fail to ensure make-up water (minimum 15 L/bather) is added to the pool daily
      • Operator to ensure minimum make-up water of 15 L/bather is added to the pool daily
    • Manual tests conducted at least ½ hour prior to opening: total alkalinity, pH value, free available chlorine, total chlorine or bromine residual and water clarity
      • Fail to conduct manual tests of alkalinity, pH value, free available chlorine, total chlorine or bromine residual and water clarity at least ½ hour prior to opening facility
      • Operator to ensure manual tests conducted at least ½ hour prior to opening for alkalinity, pH value, free available chlorine, total chlorine or bromine residual and water clarity
    • Daily records completed, signed and available for viewing
      • Fail to record Cl (free and total) residual ½ hour before opening & every 2 hour (without automatic sensing device) or 4 hours (with automatic sensing device) while pool open
      • Fail to record pH residual ½ hour before opening & every 2 hours (without automatic sensing device) or 4 hours (with automatic sensing device) while pool open
      • Fail to record reading of the make-up water meter
      • Fail to record total number of bathers admitted to pool each day
      • Fail to record total alkalinity ½ hour before opening and every 2 hours while pool is open (every 4 hours with automatic sensing device)
      • Fail to record water clarity observation ½ hour before opening and every 2 hours while pool is open (every 4 hours with automatic sensing device)
      • Operator to ensure daily records are completed, signed and available for viewing by Medical Officer of Health or Public Health Inspector at any time
    • Other records signed and completed
      • Fail to determine cyanurate stabilization at least 1/week
      • Operator to ensure cyanurate stabilization is determined and recorded at least 1/week