Drip in Luxe Medical & Beauty Spa
106 50 Richmond Rd E, Oshawa ON · Know Before You Go Inspections
3 inspections
- Re-Inspection
0 infractions
- Routine
3 infractions
- For invasive services an explanation of the procedure, associated risks and appropriate aftercare are provided to clients
- For electrolysis and laser hair removal, aftercare instructions may include, but are not limited to: Direction to clean hands immediately before touching the site; expected healing time of the site; a description of possible complications and their signs and symptoms; advice on how to deal with slight redness, pain or swelling; a recommendation to consult with a physician within 24 hours if any signs of infection develop following the procedure; ointment or astringent may be applied to soothe the skin.
- Approved disinfectants are prepared and used appropriately, and records maintained
- Fail to prepare, maintain and discard solution according to the manufacturer’s instructions (e.g. expired products). Operator/PSW must prepare, maintain and discard solutions according to the manufacturer's instructions (e.g. expired products).
- Fail to keep high-level disinfectant records with product name, concentration, date prepared and date to be discarded (as applicable). Operator/PSW must keep disinfection records with product name, concentration, date prepared and date to be discarded (as applicable).
- For invasive procedures, appropriate records are maintained
- Fail to record that information about risks associated with invasive procedure was provided to the client. Operator/PSW must record that information about risks associated with invasive procedure was provided to the client.
- Fail to record that verbal and written after-care information was provided. Operator/PSW must record that verbal and written after-care information was provided.
- For invasive services an explanation of the procedure, associated risks and appropriate aftercare are provided to clients
- Routine
4 infractions
- Approved disinfectants are prepared and used appropriately, and records maintained
- Fail to prepare, maintain and discard solution according to the manufacturer’s instructions (e.g. expired products). Operator/PSW must prepare, maintain and discard solutions according to the manufacturer's instructions (e.g. expired products).
- For invasive procedures, appropriate records are maintained
- Fail to record client’s complete mailing address. Operator/PSW must record client’s complete mailing address.
- Fail to record that information about risks associated with invasive procedure was provided to the client. Operator/PSW must record that information about risks associated with invasive procedure was provided to the client.
- Fail to record body part/area on which procedure was performed on. Operator/PSW must record body part/area on which procedure was performed on.
- Fail to record that verbal and written after-care information was provided. Operator/PSW must record that verbal and written after-care information was provided.
- All reusable items and/or equipment cleaned and then disinfected or sterilized, as applicable
- Fail to provide and use an appropriate level disinfectant to disinfect reusable items and/or equipment. Operator/PSW must provide and use an appropriate level disinfectant to disinfect reusable items and/or equipment.
- All items that cannot be cleaned, disinfected or sterilized must be single-use disposable
- Fail to discard single-use disposable items and/or items that cannot be readily cleaned and disinfected or sterilized immediately after each use or when contaminated (e.g. pedicure razor blades). Operator/PSW must discard single-use disposable items and/or items that cannot be readily cleaned and disinfected or sterilized immediately after each use or when contaminated (e.g. pedicure razor blades).
- Approved disinfectants are prepared and used appropriately, and records maintained