Emerald Point Condo Spa
1665 Pickering Pky, Pickering ON L1V 6L4 · Spa
10 inspections
- Routine
0 infractions
- Re-Inspection
0 infractions
- Routine
1 infraction
- Safety equipment available and in good repair
- Fail to provide a sufficiently supplied first-aid kit
- Operator to provide a first-aid kit with contents as prescribed by the Regulation
- Safety equipment available and in good repair
- Routine
0 infractions
- Routine
0 infractions
- Re-Inspection
0 infractions
- Routine
4 infractions
- Free available chlorine (FAC) or total bromine within range of 5-10 ppm
- CLOSE SPA
- Fail to maintain FAC or total bromine within range of 5-10 ppm
- Operator to ensure FAC or total bromine is within range of 5-10 ppm
- If equipped with an automatic sensing device, total alkalinity, pH value, free available chlorine, total chlorine or bromine residual, water clarity, and water temperature are checked at least every 4 hours until the daily use period has ended
- Fail to test total alkalinity every 4 hours
- Fail to test pH value every 4 hours
- Fail to test total bromine every 4 hours
- Fail to check water clarity every 4 hours
- Fail to check water temperature every 4 hours
- Operator to ensure all checks and tests are completed at least every 4 hours
- Daily records completed and signed
- Fail to record estimated number of bather uses during daily use period
- Operator to ensure that all records are completed and signed daily as required by the Regulation
- Premises is maintained free from every serious condition that may be a health hazard
- CLOSE SPA
- Fail to ensure spa is free from every serious condition that may be a health hazard
- Operator to ensure spa is free from every serious condition that may be a health hazard
- Free available chlorine (FAC) or total bromine within range of 5-10 ppm
- Routine
0 infractions
- Routine
3 infractions
- Manual tests conducted at least ½ hour prior to opening: total alkalinity, pH value, free available chlorine, total chlorine or bromine residual and water clarity
- Fail to conduct manual tests of alkalinity, pH value, free available chlorine, total chlorine or bromine residual and water clarity at least ½ hour prior to opening facility
- Operator to ensure manual tests conducted at least ½ hour prior to opening for alkalinity, pH value, free available chlorine, total chlorine or bromine residual and water clarity
- If equipped with an automatic sensing device, total alkalinity, pH value, free available chlorine, total chlorine or bromine residual, water clarity, and water temperature are checked at least every 4 hours until the daily use period has ended
- Fail to test total alkalinity every 4 hours
- Fail to test pH value every 4 hours
- Fail to test total bromine every 4 hours
- Fail to check water clarity every 4 hours
- Fail to check water temperature every 4 hours
- Operator to ensure all checks and tests are completed at least every 4 hours
- Daily records completed and signed
- Fail to complete and sign records daily
- Fail to record estimated number of bather uses during daily use period
- Fail to record free available chlorine or total bromine residual
- Fail to record pH value
- Fail to record total alkalinity
- Fail to record water clarity
- Fail to record water temperature
- Operator to ensure that all records are completed and signed daily as required by the Regulation
- Manual tests conducted at least ½ hour prior to opening: total alkalinity, pH value, free available chlorine, total chlorine or bromine residual and water clarity
- Routine
0 infractions