Everwild Nordic Spa & Hotel - Whirlpool
1 Silvertip Trail Canmore AB T1W 2Z7 · Aquatic Facility
18 inspections
- Demand Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1) Both skimmers were missing floating weirs. - Please install weirs to maximize and control flow through the skimmers. 2) Jet flow rate was too high and combined flow (165 GPM) exceeds the flow the covers are rated for (150 GPM).- Please throttle back Jet Flow to not exceed 75 GPM as per your written operational plans.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample from Monday June 29th, 2026, had an HPC of 210 CFU/ml. - Operators were informed to treat and re-sample.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1) Both skimmers were missing floating weirs. - Please install weirs to maximize and control flow through the skimmers. 2) Jet flow rate was too high and combined flow (165 GPM) exceeds the flow the covers are rated for (150 GPM).- Please throttle back Jet Flow to not exceed 75 GPM as per your written operational plans.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1) Both skimmers were missing floating weirs. - Please install weirs to maximize and control flow through the skimmers. 2) Jet flow rate was too high and combined flow (165 GPM) exceeds the flow the covers are rated for (150 GPM).- Please throttle back Jet Flow to not exceed 75 GPM as per your written operational plans.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- June 8, 2026 water sample had Pseudomonas isolated. Close whirlpool until treatment is done to remove contamination. New sample to be submitted after treatment.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- June 8, 2026 water sample had a plate count of 120cfu/ml. Treat water to remove contamination. Submit a new water sample after treatment.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample from Monday May 4th, 2026, had Pseudomonas isolated. - Operators were informed to treat and re-sample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample from Monday September 22nd, 2025, had an HPC of 290 CFU/ml. Operators were informed to treat and re-sample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total Alkalinity was slightly high at 196 ppm. -Please drain some water to lower the TA to be within the 60-180ppm range.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample from Monday November 18th, 2024, had an HPC of 910 CFU/ml.- Operators were informed to treat and re-sample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample from Monday September 32rd, 2024, had Total Coliforms present. - Operators were informed to treat and submit a re-sample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample from Monday September 32rd, 2024, had Total Coliforms present. - Operators were informed to treat and submit a re-sample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample from Tuesday September 3rd, 2024, had Total Coliforms present. - Operators were informed to treat and submit a re-sample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Initial Inspection
0 infractions
- Initial Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- No water sample has been submitted. - Please submit a water sample as soon as possible.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The max flow of the system (Jet and circ pumps) exceeds the maximum rated flow of the covers. - Please reduce the flow and ensure the max flow does not exceed the allowed flow per drain cover (150 GPM).
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?