Foreman (H/S)

3235 N LeClaire (5100W), CHICAGO, IL 60641 · School

27 inspections

  1. Canvass

    0 infractions

  2. Canvass

    1 infraction

    • 51. PLUMBING INSTALLED; PROPER BACKFLOW DEVICES
      • OBSERVED SLOW DRAINING EXPOSED HANDWASHING SINK NEAR SERVING LINE. INSTRUCTED THE PERSON IN CHARGE TO REPAIR AND MAINTAIN SO THAT THE SINK DRAINS PROPERLY.
  3. Canvass Re-Inspection

    0 infractions

  4. Canvass

    3 infractions

    • 36. THERMOMETERS PROVIDED & ACCURATE
      • THE THERMOMETER GAUGE ATTACHED TO THE HOT HOLDING UNIT AT THE SERVICE LINE IS NOT OPERATIONAL. MUST REPAIR OR PROVIDE A WORKING THERMOMETER INSIDE OF THE HOT HOLDING UNIT.
    • 55. PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
      • OBSERVED CHIPPED AND PEELING PAINT ON THE WALL OUTSIDE OF THE DOOR FRAME TO WALK-IN COOLER #2. MUST SCRAPE AND REPAINT THE CHIPPED PAINT ON THE WALL.
    • 60. PREVIOUS CORE VIOLATION CORRECTED
      • PREVIOUS CORE VIOLATION FROM REPORT #2555989 ON 5/19/22 NOT CORRECTED: 55 - OBSERVED DAMAGED CEILING TILES WITH A BLACK SUBSTANCE ON THEM IN WALK-IN COOLER #2 LOCATED IN THE REAR KITCHEN PREPARATION AREA. ALSO OBSERVED PEELING PAINT ON THE CEILING LOCATED IN THE KITCHEN PREPARATION AREA. INSTRUCTED TO REPLACE CEILING TILES IN WALK-IN COOLER AND REPAIR CEILING IN KITCHEN PREPARATION AREA AND MAINTAIN. PRIORITY FOUNDATION VIOLATION 7-42-090.
  5. Canvass

    3 infractions

    • 51. PLUMBING INSTALLED; PROPER BACKFLOW DEVICES
      • OBSERVED LEAK AT BASE OF FAUCET AT TWO COMPARMENT SINK LOCATED NEAR THE ICE MACHINE IN THE KITCHEN PREPARATION AREA. INSTRUCTED TO REPAIR AND MAINTAIN.
    • 55. PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
      • OBSERVED DAMAGED CEILING TILES WITH A BLACK SUBSTANCE ON THEM IN WALK-IN COOLER #2 LOCATED IN THE REAR KITCHEN PREPARATION AREA. ALSO OBSERVED PEELING PAINT ON THE CEILING LOCATED IN THE KITCHEN PREPARATION AREA. INSTRUCTED TO REPLACE CEILING TILES IN WALK-IN COOLER AND REPAIR CEILING IN KITCHEN PREPARATION AREA AND MAINTAIN.
    • 56. ADEQUATE VENTILATION & LIGHTING; DESIGNATED AREAS USED
      • OBSERVED NO LIGHTING IN WALK-IN COOLER #1 IN THE REAR KITCHEN PREPARATION AREA. INSTRUCTED TO PROVIDE ADEQUATE LIGHTING AND MAINTAIN.
  6. Canvass Re-Inspection

    2 infractions

    • 33. PROPER COOLING METHODS USED; ADEQUATE EQUIPMENT FOR TEMPERATURE CONTROL
      • OBSERVED WALK IN COOLER #2 IN PREP AREA AT INTERNAL TEMPERATURE OF 52.7F AND MILK WALK IN COOLER NEAR SERVING LINE AT INTERNAL TEMPERATURE OF 45.9F. BOTH UNITS HAVE BEEN TAGGED FOR REINSPECTION. ALL COLD HOLDING EQUIPMENT MUST MAINTAIN INTERNAL TEMPERATURE OF 41F OR BELOW. PRIORITY. 7-38-005. NO CITATION ISSUED.
    • 55. PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
      • OBSERVED PEELING PAINT ON CEILINGS IN THIRD FLOOR WOMEN'S (SOUTH) RESTROOM. MUST REPAIR AND MAINTAIN.
  7. Canvass Re-Inspection

    3 infractions

    • 10. ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
      • MAXIMUM TEMPERATURES OF 68.9F IN MEN AND WOMEN'S WASHROOMS ON NORTH SIDE OF ANNEX. ALL HANDWASHING SINKS MUST REACH MINIMUM TEMPERATURE OF 100F. PRIORITY. 7-38-030(c). NO CITATION ISSUED.
    • 33. PROPER COOLING METHODS USED; ADEQUATE EQUIPMENT FOR TEMPERATURE CONTROL
      • OBSERVED WALK IN COOLER #2 IN PREP AREA AT INTERNAL TEMPERATURE OF 52.7F AND MILK WALK IN COOLER NEAR SERVING LINE AT INTERNAL TEMPERATURE OF 45.9F. BOTH UNITS HAVE BEEN TAGGED FOR REINSPECTION. ALL COLD HOLDING EQUIPMENT MUST MAINTAIN INTERNAL TEMPERATURE OF 41F OR BELOW. PRIORITY. 7-38-005. NO CITATION ISSUED.
    • 55. PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
      • OBSERVED PEELING PAINT ON CEILINGS IN THIRD FLOOR WOMEN'S RESTROOM. MUST REPAIR AND MAINTAIN.
  8. Canvass

    6 infractions

    • 10. ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
      • MAXIMUM HANDWASHING SINK TEMPERATURE OF 95.1F IN MEN'S ANNEX (SOUTH) WASHROOM AND MAXIMUM TEMPERATURES OF 68.9F IN MEN AND WOMEN'S WASHROOMS ON NORTH SIDE OF ANNEX. MAXIMUM HANDWASHING SINK TEMPERATURE OF 88.7 IN WOMEN'S MAIN BUILDING THIRD FLOOR WASHROOM AND MAXIMUM HANDWASHING SINK TEMPERATURE OF 86.1F IN THIRD FLOOR MEN'S WASHROOM OF MAIN BUILDING. ALL HANDWASHING SINKS MUST REACH MINIMUM TEMPERATURE OF 100F. PRIORITY. 7-38-030(c). NO CITATION ISSUED.
    • 33. PROPER COOLING METHODS USED; ADEQUATE EQUIPMENT FOR TEMPERATURE CONTROL
      • OBSERVED WALK IN COOLER #2 IN PREP AREA AT INTERNAL TEMPERATURE OF 52.7F AND MILK WALK IN COOLER NEAR SERVING LINE AT INTERNAL TEMPERATURE OF 45.9F. BOTH UNITS HAVE BEEN TAGGED FOR REINSPECTION. ALL COLD HOLDING EQUIPMENT MUST MAINTAIN INTERNAL TEMPERATURE OF 41F OR BELOW. PRIORITY. 7-38-005. NO CITATION ISSUED.
    • 37. FOOD PROPERLY LABELED; ORIGINAL CONTAINER
      • OBSERVED CONTAINER OF SUGAR IN PREP AREA WITHOUT LABEL. ALL CONTAINERS OF FOOD NOT IN ORIGINAL PACKAGING MUST BE LABELED.
    • 47. FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED
      • OBSERVED SLIME-LIKE SUBSTANCE ON LINER INSIDE OF ICE MACHINE IN KITCHEN. MUST CLEAN AND MAINTAIN.
    • 55. PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
      • OBSERVED PEELING PAINT ON CEILINGS IN THIRD FLOOR WOMEN'S RESTROOM. MUST REPAIR AND MAINTAIN.
    • 56. ADEQUATE VENTILATION & LIGHTING; DESIGNATED AREAS USED
      • OBSERVED MISSING LIGHT BULB IN WALK IN FREEZER #2 IN LUNCHROOM. MUST REPLACE AND MAINTAIN.
  9. Canvass Re-Inspection

    1 infraction

    • 10. ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
      • OBSERVED NO HAND WASHING SINK IN THE SERVING ROOM. A HAND WASHING SINK MUST BE LOCATED TO ALLOW CONVENIENT USE BY FOOD EMPLOYEES IN THE SERVING ROOM. INSTRUCTED FACILITY TO INSTALL HAND WASHING SINK WITH HOT AND COLD RUNNING WATER UNDER CITY PRESSURE. PRIORITY FOUNDATION 7-38-030(C). NO CITATION ISSUED. -
  10. Canvass Re-Inspection

    5 infractions

    • 10. ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
      • 5-204.11-OBSERVED NO HAND WASHING SINK IN THE SERVING ROOM. A HAND WASHING SINK MUST BE LOCATED TO ALLOW CONVENIENT USE BY FOOD EMPLOYEES IN THE SERVING ROOM. INSTRUCTED FACILITY TO INSTALL HAND WASHING SINK WITH HOT AND COLD RUNNING WATER UNDER CITY PRESSURE. PRIORITY FOUNDATION 7-38-030(C). NO CITATION ISSUED. -
    • 51. PLUMBING INSTALLED; PROPER BACKFLOW DEVICES
      • upgraded to priority foundation
    • 55. PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
      • 6-501.11- DAMAGED WALLS AND PELLING PAINT ON THE WALLS AND CEILING IN THE 2ND FLOOR AND 3RD FLOOR STAFF WASHROOM(MEN AND WOMEN), INSTRUCTED TO SCRAPE OFF PEELING PAINT AND RE PAINT AND REPAIR DAMAGED WALLS AND MAINTAIN.
    • 56. ADEQUATE VENTILATION & LIGHTING; DESIGNATED AREAS USED
      • 4-202.18-FILTERS ON THE HOOD ABOVE THE STOVES WITH DUST BUILD-UP. MUST CLEAN AND MAINTAIN.
    • 60. PREVIOUS CORE VIOLATION CORRECTED
      • 8-404.13(B:4)-PREVIOUS CORE VIOLATION NOT CORRECTED FROM REPORT #22585489 DATED 4/22/19. #51- 5-204.12- BACK FLOW PREVENTION DEVICE NOT LOCATED AT ICE MACHINE LOCATED IN KITCHEN. MUST INSTALL BACK FLOW PREVENTION DEVICE AT WATER LINE SO IT MAY BE LOCATED TO BE SERVICED AND MAINTAINED. PRIORITY FOUNDATION 7-42-090 NO CITATION ISSUED(CPS). MUST BE CORRECTED BY 4/1/20.
  11. Canvass

    6 infractions

    • 10. ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
      • OBSERVED NO HAND WASHING SINK IN THE SERVING ROOM. A HAND WASHING SINK MUST BE LOCATED TO ALLOW CONVENIENT USE BY FOOD EMPLOYEES IN THE SERVING ROOM. INSTRUCTED FACILITY TO INSTALL HAND WASHING SINK WITH HOT AND COLD RUNNING WATER UNDER CITY PRESSURE. PRIORITY FOUNDATION 7-38-030(C). NO CITATION ISSUED. -
    • 38. INSECTS, RODENTS, & ANIMALS NOT PRESENT
      • DOOR #9 WITH A GAP ON THE RIGHT BOTTOM OF THE DOOR. INSTRUCTED TO REPAIR, MAKE THE DOOR TIGHT FITTING AND RODENT,INSECTS PROOFED AND MAINTAIN.
    • 51. PLUMBING INSTALLED; PROPER BACKFLOW DEVICES
      • UPGRADED TO PRIORITY FOUNDATION.
    • 55. PHYSICAL FACILITIES INSTALLED, MAINTAINED & CLEAN
      • ONE OUT OF TWO HAND DRYER IS NOT WORKING,IN THE GIRL'S WASHROOM 1ST FLOOR. MUST REPAIR AND MAINTAIN. DAMAGED WALLS AND PELLING PAINT ON THE WALLS AND CEILING IN THE 2ND FLOOR AND 3RD FLOOR STAFF WASHROOM(MEN AND WOMEN), INSTRUCTED TO SCRAPE OFF PEELING PAINT AND RE PAINT AND REPAIR DAMAGED WALLS AND MAINTAIN.
    • 56. ADEQUATE VENTILATION & LIGHTING; DESIGNATED AREAS USED
      • FILTERS ON THE HOOD ABOVE THE STOVES WITH DUST BUILD-UP. MUST CLEAN AND MAINTAIN.
    • 60. PREVIOUS CORE VIOLATION CORRECTED
      • PREVIOUS CORE VIOLATION N OT CORRECTED FROM REPORT #22585489 DATED 4/22/19. #51- 5-204.12- BACK FLOW PREVENTION DEVICE NOT LOCATED AT ICE MACHINE LOCATED IN KITCHEN. MUST INSTALL BACK FLOW PREVENTION DEVICE AT WATER LINE SO IT MAY BE LOCATED TO BE SERVICED AND MAINTAINED. PRIORITY FOUNDATION 7-42-090 NO CITATION ISSUED(CPS). MUST BE CORRECTED BY 2/28/20.
  12. Canvass

    4 infractions

    • 10. ADEQUATE HANDWASHING SINKS PROPERLY SUPPLIED AND ACCESSIBLE
      • OBSERVED NO HAND WASHING SINK IN THE SERVING ROOM. A HAND WASHING SINK MUST BE LOCATED TO ALLOW CONVENIENT USE BY FOOD EMPLOYEES IN THE SERVING ROOM. INSTRUCTED FACILITY TO INSTALL HAND WASHING SINK WITH HOT AND COLD RUNNING WATER UNDER CITY PRESSURE. PRIORITY FOUNDATION 7-38-030(C). NO CITATION ISSUED. -
    • 47. FOOD & NON-FOOD CONTACT SURFACES CLEANABLE, PROPERLY DESIGNED, CONSTRUCTED & USED
      • CUTTING BOARDS WITH OPEN SEAMS AND DARK STAINS. MUST REFINISH OR REPLACE DAMAGED OR STAINED CUTTING BOARDS.
    • 51. PLUMBING INSTALLED; PROPER BACKFLOW DEVICES
      • BACK FLOW PREVENTION DEVICE NOT LOCATED AT ICE MACHINE LOCATED IN KITCHEN. MUST INSTALL BACK FLOW PREVENTION DEVICE AT WATER LINE SO IT MAY BE LOCATED TO BE SERVICED AND MAINTAINED.
    • 51. PLUMBING INSTALLED; PROPER BACKFLOW DEVICES
      • OBSERVED SMALL WATER LEAK AT BASE OF MIDDLE FAUCET AT THE DISH WASHING 3 COMPARTMENT SINK.INSTRUCTED TO REPAIR PLUMBING LEAK AND TO MAINTAIN.
  13. Canvass Re-Inspection

    0 infractions

  14. Canvass

    3 infractions

    • 24. DISH WASHING FACILITIES: PROPERLY DESIGNED, CONSTRUCTED, MAINTAINED, INSTALLED, LOCATED AND OPERATED
      • FOUND DISH WASHING FACILITIES NOT PROPERLY MAINTAINED. WASTEWATER BACKING UP FROM ONE COMPARTMENT INTO ANOTHER COMPARTMENT OF THE 3 COMPARTMENT SINK AND INTO 2 COMPARTMENT SINK. INSTRUCTED TO REPAIR. SERIOUS VIOLATION 7-38-030
    • 31. CLEAN MULTI-USE UTENSILS AND SINGLE SERVICE ARTICLES PROPERLY STORED: NO REUSE OF SINGLE SERVICE ARTICLES
      • ALL SINGLE PLASTIC UTENSILS IN A HOLDING CONTAINER MUST BE STORED WITH HANDLES FACING UP/OUT.
    • 33. FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS
      • INSTRUCTED TO DETAIL CLEAN AND MAINTAIN INTERIOR SURFACES OF (2) MICROWAVE OVENS WITH EXCESSIVE DRIED FOOD ACCUMULATION TO PREVENT PEST HARBORAGE (LOCATED IN STUDENT DINING ROOM).
  15. Canvass Re-Inspection

    1 infraction

    • 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
      • PEELING PAINT ON THE CEILING AND WALLS INSIDE THE ONE OF THE WALK IN COOLER, INSIDE THE STAFF WASHROOMS IN ALL THREE FLOORS. MUST SCRAPE PEELING PAINT AND REPAINT.
  16. Canvass

    4 infractions

    • 16. FOOD PROTECTED DURING STORAGE, PREPARATION, DISPLAY, SERVICE AND TRANSPORTATION
      • INTERIOR PANEL OF THE ICE MAKER NOT MAINTAINED. YELLOWISH/ORANGE COLOR ON THE MOLDY LIKE SUBSTANCE ON THE SURFACES OF THE PLASTIC TUBE WHERE THE WATER IS COMING FROM. INSTRUCTED TO CLEAN IN DETAIL AND SANITIZE. SERIOUS VIOLATION 7-38-005(A). INSTRUCTED NOT TO USE THE ICE MAKER NOT UNTIL IT IS CLEANED AND SANITIZED.
    • 18. NO EVIDENCE OF RODENT OR INSECT OUTER OPENINGS PROTECTED/RODENT PROOFED, A WRITTEN LOG SHALL BE MAINTAINED AVAILABLE TO THE INSPECTORS
      • FRONT ENTRANCE DOOR ON THE FIRST FLOOR AND SELF ENTRANCE DOOR ON THE FIRST FLOOR NOT RODENT/INSECTS PROOFED WITH OVER 1/4 OF AN INCH GAP ON THE BOTTOM OF THE DOOR. INSTRUCTED TO RODENT/INSECTS PROOFED THE DOORS. SERIOUS VIOLATION 7-38-020.
    • 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
      • PEELING PAINT ON THE CEILING AND WALLS INSIDE THE ONE OF THE WALK IN COOLER, INSIDE THE STAFF WASHROOMS IN ALL THREE FLOORS. MUST SCRAPE PEELING PAINT AND REPAINT. DUST ACCUMULATED ON THE FAN GUARD OF BOTH WALK IN COOLER. MUST CLEAN REMOVE DUST AND MAINTAIN. DAMAGED WALLS ON THE LEFT RIM OF THE WALK IN COOLER IN THE KITCHEN. MUST REPAIR WALLS AND MAINTAIN.
    • 36. LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
      • BURNED OUT LIGHT BULB ON THE HOOD/CANOPY IN THE COOK LINE. MUST REPLACE AND MAINTAIN.
  17. Complaint Re-Inspection

    3 infractions

    • 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
      • OBSERVED CRACKED OR MISSING BASEBOARD TILES IN SERVING AREA AND ALSO IN DRY STORAGE ROOM. INSTRUCTED TO REPAIR AND MAINTAIN.
    • 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
      • OBSERVED PEELING PAINT ON CEILING OUTSIDE OF LUNCH ROOM ENTRY WAY. INSTRUCTED TO REPAIR AND MAINTAIN ALL PEELING PAINT ON WALLS AND CEILINGS IN HALLWAYS
    • 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
      • OBSERVED MISSING SENSOR PLATES ON PARTS OF THE SINKS IN THE FOLLOWING STUDENT RESTROOMS: 1ST FLOOR NORTH GIRLS RESTROOM; 1ST FLOOR NORTH BOYS RESTROOM. OBSERVED 2ND FLOOR SOUTH BOYS RESTROOM WITH LEFT SINK NOT WORKING. OBSERVED 3RD FLOOR GIRLS RESTROOM WITH MISSING FLUSH BUTTON ON WALL ABOVE TOLIET. OBSERVED WATER TEMPERATURE IN ALL BATHROOMS RANGING FROM 43F - 85F. INSTRUCTED ENGINEER MUST HAVE CONSISTENT TEMPERATURE TO A MINIMIUM OF 85F IN ALL RESTROOMS. INSTRUCTED TO REPAIR AND MAINTAIN ALL SINKS AND TOILETS FOR ALL RESTROOMS
  18. Complaint

    4 infractions

    • 16. FOOD PROTECTED DURING STORAGE, PREPARATION, DISPLAY, SERVICE AND TRANSPORTATION
      • OBSERVED DUST AND FIRE EXTINQUISHER EXPELLENT ON VENTS AND INSIDE OF RIM OF ICE MACHINE. INSTRUCTED TO BURN ICE, CLEAN AND SANITIZE MACHINE BEFORE USE. MACHINE TAGGED AND HELD FOR INSECTION. FACILITY WILL USE BAGGED ICED UNTIL TAG REMOVAL. SERIOUS VIOLATION 7-38-005(A).
    • 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
      • OBSERVED CRACKED OR MISSING BASEBOARD TILES IN SERVING AREA AND ALSO IN DRY STORAGE ROOM. INSTRUCTED TO REPAIR AND MAINTAIN.
    • 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
      • OBSERVED PEELING PAINT ON CEILING OUTSIDE OF LUNCH ROOM ENTRY WAY. INSTRUCTED TO REPAIR AND MAINTAIN ALL PEELING PAINT ON WALLS AND CEILINGS IN HALLWAYS
    • 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
      • OBSERVED MISSING SENSOR PLATES ON PARTS OF THE SINKS IN THE FOLLOWING STUDENT RESTROOMS: 1ST FLOOR NORTH GIRLS RESTROOM; 1ST FLOOR NORTH BOYS RESTROOM. OBSERVED 2ND FLOOR SOUTH BOYS RESTROOM WITH LEFT SINK NOT WORKING. OBSERVED 3RD FLOOR GIRLS RESTROOM WITH MISSING FLUSH BUTTON ON WALL ABOVE TOLIET. OBSERVED WATER TEMPERATURE IN ALL BATHROOMS RANGING FROM 43F - 85F. INSTRUCTED ENGINEER MUST HAVE CONSISTENT TEMPERATURE TO A MINIMIUM OF 85F IN ALL RESTROOMS. INSTRUCTED TO REPAIR AND MAINTAIN ALL SINKS AND TOILETS FOR ALL RESTROOMS
  19. Canvass Re-Inspection

    4 infractions

    • 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
      • OBSERVED CRACKED OR MISSING BASEBOARD TILES IN SERVING AREA AND ALSO IN DRY STORAGE ROOM. INSTRUCTED TO REPAIR AND MAINTAIN
    • 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
      • OBSERVED PEELING PAINT ON CEILING OUTSIDE OF LUNCH ROOM ENTRY WAY. INSTRUCTED TO REPAIR AND MAINTAIN ALL PEELING PAINT ON WALLS AND CEILINGS IN HALLWAYS.
    • 36. LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
      • OBSERVED SEVERAL OVER HEAD LIGHTING NOT WORKING IN LUNCH ROOM, AND ALSO IN SERVING LINE. INSTRUCTED TO REPAIR AND MAINTAIN TO PROVIDE ADEQUATE LIGHTING THROUGHOUT.
    • 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
      • OBSERVED MISSING SENSOR PLATES ON PARTS OF THE SINKS IN THE FOLLOWING STUDENT RESTROOMS: 1ST FLOOR NORTH GIRLS RESTROOM; 1ST FLOOR NORTH BOYS RESTROOM. OBSERVED 2ND FLOOR SOUTH BOYS RESTROOM WITH LEFT SINK NOT WORKING. OBSERVED 3RD FLOOR GIRLS RESTROOM WITH MISSING FLUSH BUTTON ON WALL ABOVE TOLIET. OBSERVED WATER TEMPERATURE IN ALL BATHROOMS RANGING FROM 43F - 85F. INSTRUCTED ENGINEER MUST HAVE CONSISTENT TEMPERATURE TO A MINIMIUM OF 85F IN ALL RESTROOMS. INSTRUCTED TO REPAIR AND MAINTAIN ALL SINKS AND TOILETS FOR ALL RESTROOMS
  20. Canvass

    5 infractions

    • 11. ADEQUATE NUMBER, CONVENIENT, ACCESSIBLE, DESIGNED, AND MAINTAINED
      • OBSERVED ONLY EXPOSED HAND SINK IN PREP AREA NOT PROPERLY FUNCTIONING. LEFT SIDE COLD FAUCET WITH HANDLE THAT DOES NOT TURN ON. RIGHT SIDE HOT METERED PUSH FAUCET WHICH IS NOT PROPERLY TEMPERED. MANAGER STATED MOST OF THE TIME THE WATER IS TOO HOT (139F AT BEGINING OF INSPECTION) TO WASH HANDS, OTHER TIMES IT IS VERY COLD (61.6F AT END OF INSPECTION). INSTRUCTED TO PROVIDE KITCHEN WITH PROPERLY FUNCTIONING EXPOSED HAND SINK WITH HOT AND COLD OR TEMPERED (85F) RUNNING WATER. CRITICAL VIOLATION 7-38-030.
    • 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
      • OBSERVED CRACKED OR MISSING BASEBOARD TILES IN SERVING AREA AND ALSO IN DRY STORAGE ROOM. INSTRUCTED TO REPAIR AND MAINTAIN.
    • 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
      • OBSERVED PEELING PAINT ON CEILING OUTSIDE OF LUNCH ROOM ENTRY WAY. INSTRUCTED TO REPAIR AND MAINTAIN ALL PEELING PAINT ON WALLS AND CEILINGS IN HALLWAYS.
    • 36. LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
      • OBSERVED SEVERAL OVER HEAD LIGHTING NOT WORKING IN LUNCH ROOM, AND ALSO IN SERVING LINE. INSTRUCTED TO REPAIR AND MAINTAIN TO PROVIDE ADEQUATE LIGHTING THROUGHOUT.
    • 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
      • OBSERVED MISSING SENSOR PLATES ON PARTS OF THE SINKS IN THE FOLLOWING STUDENT RESTROOMS: 1ST FLOOR NORTH GIRLS RESTROOM; 1ST FLOOR NORTH BOYS RESTROOM. OBSERVED 2ND FLOOR SOUTH BOYS RESTROOM WITH LEFT SINK NOT WORKING. OBSERVED 3RD FLOOR GIRLS RESTROOM WITH MISSING FLUSH BUTTON ON WALL ABOVE TOLIET. OBSERVED WATER TEMPERATURE IN ALL BATHROOMS RANGING FROM 43F - 85F. INSTRUCTED ENGINEER MUST HAVE CONSISTENT TEMPERATURE TO A MINIMIUM OF 85F IN ALL RESTROOMS. INSTRUCTED TO REPAIR AND MAINTAIN ALL SINKS AND TOILETS FOR ALL RESTROOMS.
  21. Canvass

    4 infractions

    • 29. PREVIOUS MINOR VIOLATION(S) CORRECTED 7-42-090
      • PREVIOUS MINOR VIOLATION FROM 4-4-14 NOT CORRECTED.#32- NOTED MISSING SNEEZE GUARD AT HOTLINE IN SERVICE AREA. INSTRUCTED TO REPLACE MISSING SNEEZE GUARD. SERIOUS VIOLATION #7-42-090. ENGINEER WAS ABLE TO CORRECT DURING THE INSPECTION BY REPLACING GUARDS FROM AN UNUSED HOT HOLDING LINE.
    • 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
      • DIRTY WALL UNDER THE KITCHEN EXPOSED HAND SINK. CLEANED DURING THE INSPECTION.
    • 36. LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
      • LIGHT BULB REPLACED INSIDE WALK-IN COOLER #1.
    • 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
      • LEAK ON THE COLD HANDLE OF THE NOZZLE ON THE KITCHEN THREE COMPARTMENT SINK.
  22. Canvass

    3 infractions

    • 32. FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
      • NOTED MISSING SNEEZE GUARD AT HOTLINE IN SERVICE AREA. INSTRUCTED TO REPLACE MISSING SNEEZE GUARD.---------- MUST CLEAN AND REPAINT EXTERIOR (TOP) SURFACES OF GREASE BOX UNDERNEATH 3 COMPARTMENT SINK.
    • 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
      • NOTED WALL BY THE OFFICE IN POOR REPAIR WITH HEAVY WATER STAIN AND PEELING PAINT. INSTRUCTED TO FIX.
    • 41. PREMISES MAINTAINED FREE OF LITTER, UNNECESSARY ARTICLES, CLEANING EQUIPMENT PROPERLY STORED
      • INSTRUCTED TO DISCARD UNNECESSARY ARTICLES AND UNUSED EQUIPMENT IN DINING AREA (NEXT TO THE OFFICE).
  23. Canvass

    2 infractions

    • 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
      • WALLS, CEILING IN LUNCH ROOM , TOILET ROOMS HAVE PELLING PAINT. MUSR REMOVE PEELING PAINT AND SEAL WALLS AND CEILING.
    • 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
      • VENTILATION COVERS IN TOILET ROOMS HAVE BUILD UP OF DUST. MUST CLEAN.
  24. Canvass

    4 infractions

    • 32. FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
      • Must provide longer sneeze guards to serving tables in lunch areas, (12 inches).
    • 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
      • Walls, ceilings that peeling paint/plaster in classrooms, bathrooms in 3rd floor, and 2nd floor, shall be repaired/sealed. south end staircase had peeling paint, shall be repaired/sealed.
    • 36. LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
      • Light shields in kitchen/prep areas, serving lines in luchroom not clean, need detailed cleaning.
    • 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
      • Exhaust canopy not clean, needs detailed cleaning, exhaust vents(ventilation)in bathrooms in 3rd floor, 2nd floor 1st floor not clean need detailed cleaning. Leaking pipe in bsmt, by furnace area shall be repaired/replaced.
  25. Canvass

    6 infractions

    • 32. FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
      • All food and non-food contact equipment and utensils shall be smooth, easily cleanable, and durable, and shall be in good repair. DAMAGED SCREEN WINDOWS IN THE DINING AREA MUST BE REPLACED; VENT COVER IN WASHROOM FOR EMPLOYEES DIRTY,MUST CLEAN AND MAINTAIN
    • 33. FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS
      • All food and non-food contact surfaces of equipment and all food storage utensils shall be thoroughly cleaned and sanitized daily. COMPRESSOR/ELECTRICAL EQUIPMENT IN WALK IN COOLER UNCLEAN,MUST CLEAN AND MAINTAIN
    • 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
      • The walls and ceilings shall be in good repair and easily cleaned. 3 DAMAGED BASEWALL TILES IN STORAGE ARE MUST BE REPLACED; CEILING IN WALK IN COOLER -KITCHEN DIRTY,WITH BLACK MOLDY MATERIALS,MUST CLEAN AND MAINTAIN; PEELING PAINT ON CEILING AT THE LOCKER ROOM MUST BE REMOVED,REPAINT
    • 36. LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
      • Shielding to protect against broken glass falling into food shall be provided for all artificial lighting sources in preparation, service, and display facilities. 3 BROKEN LIGHT SHIELDS IN DINING AREA MUST BE REPLACED
    • 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
      • All plumbing fixtures, such as toilets, sinks, washbasins, etc., must be adequately trapped, vented, and re-vented and properly connected to the sewer in accordance with the plumbing chapter of the Municipal Code of Chicago and the Rules and Regulations of the Board of Health. LEAKING PIPES UNDER DISMACHINE AREA MUST BE REPAIRED; 7 FAUCETS IN LADIES AND MEN'S WASHROOMS 2ND AND 3RD FLR IN POOR REPAIR MUST BE REPAIRED
    • 40. REFRIGERATION AND METAL STEM THERMOMETERS PROVIDED AND CONSPICUOUS
      • All food establishments that display, prepare, or store potentially hazardous foods shall have calibrated metal stem thermometers, provided and conspicuous, for refrigerated and hot food units. THERMOMETER MUST BE PROVIDED IN WALK IN COOLER AND MILK COOLERS
  26. Canvass

    5 infractions

    • 33. FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS
      • Can opener in kitchen not cleaned. Instructed to detail clean and sanitize after every use.
    • 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
      • Floor in boiler room and in kitchen not cleaned. Instructed to detail clean.
    • 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
      • Ventilation covers through-out prep area not cleaned. Instructed to detail clean.
    • 36. LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
      • Light not working inside walk-in unit. Instructed to repalce missing bulb.
    • 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
      • Several faucets and urinal in boys toilet room not working. Instructed to repair faucets and urinals. Valve under dish machine leaking. Instructed to repair to prevent leak. Boiler in boiler room leaking and discarding water on floor around unit. Instructed to repair to prevent leakage.
  27. Canvass

    3 infractions

    • 33. FOOD AND NON-FOOD CONTACT EQUIPMENT UTENSILS CLEAN, FREE OF ABRASIVE DETERGENTS
      • Can opener and interior door of ice machine not cleaned. Instructed to detail clean and sanitize.
    • 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
      • Floor in along wallbase in boiler room and corner in kitchen and dishmachine not cleaned. Instructed to detail clean. Door sweep on bottom of door northwest door torn on left corner. Instructed to repair or replace sweep.
    • 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
      • Walls in hallway in several areas in seal and not storage room has peeling paint. Instructed to remove all peeling paint and repaint.