FUSION 58

3933 N BROADWAY, CHICAGO, IL 60613 · Restaurant

3 inspections

  1. Canvass

    0 infractions

  2. License Re-Inspection

    5 infractions

    • 32. FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
      • RAW WOOD ABOVE THE MOP SINK SURFACE POROUS NOT CLEANABLE.SURFACE MUST BE SMOOTH,CLEANABLE AND NON-ABSORBENT SURFACE. REMOVE DUSTY UNUSED DRAIN HOSE ATTACHED FROM AIR CONDITION VENT UNIT IN PREP AREA. WOOD STAIRCASE THAT GOES IN BASEMENT FOR SYRUP JUICE BOXES STORAGE AREA,IN POOR REPAIR/UNSTEADY,SLIPPERY.INSTRUCTED TO REPAIR SAID STAIRCASE RUSTY AT BOTTOM AND LID OF THE GREASE TRAP,UNABLE TO CLEAN,NEED TO REPAINT,ALSO CAULKIN BASE OF SAID UNIT.
    • 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
      • DEBRIS ON FLOOR AROUND HOT WATER TANK,BEHIND GREASE TRAP AND BASEMENT FLOOR WERE JUICE BOXES ARE INSTALLED
    • 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
      • HOLES ON CEILING TILES AND AROUND PIPES IN PREP AREA. LARGE OPENING BETWEEN THE CEILING TILE/WALL AND AIR CONDITION VENTILATION ABOVE 1 COMPARTMENT SINK, NEED TO REPAIR/SEAL MENTIONED AREAS. POROUS CEILING IN BASEMENT ABOVE THE SYRUP JUICE BOXES,INSTRUCTED TO REPLACE/REPAIR,ALSO SEAL WALLS AT SAME AREA,BRICK DEBRIS.SURFACE MUST BE SMOOTH,CLEANABLE AND NON-ABSORBENT SURFACE. MISSING PANELS ABOVE WALK-IN FREEZER,INSTRUCTED TO PROVIDE. PROVIDE CAULKING BETWEEN THE WALL AND EXPOSED HAND SINK AT REAR AREA.
    • 36. LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
      • NO LIGHT PROVIDED AT BASEMENT ROOM AT SYRUP JUICE BOXES AREA,NEED TO PROVIDE.
    • 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
      • MECHANICAL DRAIN AT THREE COMPARTMENT SINK LEAKING INSTRUCTED TO REPAIR OR PROVIDE WORKING STOPPERS DRAIN PIPE UNDER THE ONE COMPATMENT SINK IS LEAKING INSTRUCTED TO REPAIR CAUSE.
  3. License

    6 infractions

    • 11. ADEQUATE NUMBER, CONVENIENT, ACCESSIBLE, DESIGNED, AND MAINTAINED
      • NO EXPOSED HAND SINK INSTALLED AT FRONT PREP AREA.INSTRUCTED TO INSTALL SAID SINK UNDER CITY PLUMBING CODE.PROVIDE SOAP AND PAPER TOWELS. CRITICAL VIOLATION:7-38-030
    • 32. FOOD AND NON-FOOD CONTACT SURFACES PROPERLY DESIGNED, CONSTRUCTED AND MAINTAINED
      • RAW WOOD ABOVE THE MOP SINK SURFACE POROUS NOT CLEANABLE.SURFACE MUST BE SMOOTH,CLEANABLE AND NON-ABSORBENT SURFACE. REMOVE DUSTY UNUSED DRAIN HOSE ATTACHED FROM AIR CONDITION VENT UNIT IN PREP AREA. WOOD STAIRCASE THAT GOES IN BASEMENT FOR SYRUP JUICE BOXES STORAGE AREA,IN POOR REPAIR/UNSTEADY,SLIPPERY.INSTRUCTED TO REPAIR SAID STAIRCASE RUSTY AT BOTTOM AND LID OF THE GREASE TRAP,UNABLE TO CLEAN,NEED TO REPAINT,ALSO CAULKIN BASE OF SAID UNIT.
    • 34. FLOORS: CONSTRUCTED PER CODE, CLEANED, GOOD REPAIR, COVING INSTALLED, DUST-LESS CLEANING METHODS USED
      • DEBRIS ON FLOOR AROUND HOT WATER TANK,BEHIND GREASE TRAP AND BASEMENT FLOOR WERE JUICE BOXES ARE INSTALLED.
    • 35. WALLS, CEILINGS, ATTACHED EQUIPMENT CONSTRUCTED PER CODE: GOOD REPAIR, SURFACES CLEAN AND DUST-LESS CLEANING METHODS
      • HOLES ON CEILING TILES AND AROUND PIPES IN PREP AREA. LARGE OPENING BETWEEN THE CEILING TILE/WALL AND AIR CONDITION VENTILATION ABOVE 1 COMPARTMENT SINK, NEED TO REPAIR/SEAL MENTIONED AREAS. POROUS CEILING IN BASEMENT ABOVE THE SYRUP JUICE BOXES,INSTRUCTED TO REPLACE/REPAIR,ALSO SEAL WALLS AT SAME AREA,BRICK DEBRIS.SURFACE MUST BE SMOOTH,CLEANABLE AND NON-ABSORBENT SURFACE. MISSING PANELS ABOVE WALK-IN FREEZERR,INSTRUCTED TO PROVIDE. PROVIDE CAULKIN BETWEEN THE WALL AND EXPOSED HAND SINK AT REAR AREA.
    • 36. LIGHTING: REQUIRED MINIMUM FOOT-CANDLES OF LIGHT PROVIDED, FIXTURES SHIELDED
      • NO LIGHT PROVIDED AT BASEMENT ROOM AT SYRUP JUICE BOXES AREA,NEED TO PROVIDE.
    • 38. VENTILATION: ROOMS AND EQUIPMENT VENTED AS REQUIRED: PLUMBING: INSTALLED AND MAINTAINED
      • MECHANICAL DRAIN AT THREE COMPARTMENT SINK LEAKING INSTRUCTED TO REPAIR OR PROVIDE WORKING STOPPERS DRAIN PIPE UNDER THE ONE COMPATMENT SINK IS LEAKING INSTRUCTED TO REPAIR CAUSE.